Tuning Wiki

This is a historical revision. Read the current page or return to its history.

Page organisation in this revision
Page type
Technical article
Subject
Tuning
Parent
Simos 18
Applies to
Simos 18.1
Tool groups
None
Manufacturers
Volkswagen Group

Changes from revision 7 to revision 8

Removed text is struck through; added text is highlighted.

Scope: Engineering identifiers below are examples from the community SC8S5031_C_OEM Simos 18.1 cross-reference unless another source is identified. Match the ECU, ASW, turbo hardware, sensor configuration, calibration, units, indices and installed patches. Some community descriptions are cross-linked incorrectly; verify against the matching definition. The named calibrations are not universal safe settings. SC8S5031 reference.

What is being protected?

Turbo speed, compressor operating range, charge-air temperature and turbine/exhaust temperature can invoke different limits and responses. A torque or pressure reduction is a coordinated output, not a diagnosis on its own. After a turbocharger or intake change, a model calibrated for the original hardware may no longer accurately describe the replacement; simply changing its protection thresholds does not establish the new turbo's physical margin.

Compressor model and speed protection

ip_n_tcha_stnd is a standardised turbo-speed model map in the SC8S5031 compressor-model reference. The displayed instance has reduced inlet volumetric flow (m³/s) and compressor pressure ratio axes and rpm output. n_cmpr_mdl and n_tcha_stnd are runtime calculated quantities, not independent speed measurements. c_n_tcha_max_sp is a maximum turbo-speed setpoint for the documented torque-based protection. ip_n_tcha_max_sp_dif_act is a speed-related activation-threshold map. Its first axis references a speed-difference breakpoint but is marked NO_INPUT_QUANTITY; its second input is n_tcha_prot_grd. The extraction labels both axes in rpm; verify the first runtime input and the exact definitions and timing instead of inferring a gradient unit. Turbo-speed protection. n_tcha_lpf_prot, n_tcha_max_sp_act, n_tcha_max_sp_tran and tqi_n_tcha_max are runtime protection values. An “actual” value in a signal name does not prove a speed sensor is installed. The representable range of a calibration is not a turbocharger's mechanical rating.

For its documented MQB applications, COBB explicitly calls Turbo Shaft Speed modelled and Maximum Turbo Speed Set Point a modelled protection value. Check what the logger actually receives and whether an independent sensor is installed and configured.

Pressure ratio and compressor operating range

ip_pq_cha_max is the example maximum compressor pressure-quotient map, with engine speed and compressor-upstream air temperature axes in the SC8S5031 application reference. The source describes other contributions to the upstream-pressure top limit, including surge, ambient-sensor and turbo-speed conditions. put_max_tcha_prot is a coordinated runtime permissible upstream-pressure value, not a calibration map. Pressure-limit calculation reference.

ip_pq_cha_surge_dl is a surge-line characteristic in the SC8S5031 surge-detection reference; its displayed breakpoint axis has reduced inlet-volume-flow units but no explicit input quantity, so confirm the target definition. The neighbouring ip_pq_cha_surge_dl_hys_pl has conflicting idle/part-load labels. lv_cap_surge is a runtime logical signal, not independent proof of physically measured surge. put_max_n_tcha_max is the runtime pressure limit resulting from the speed model in the boost-limitation reference.

Compressor pressure ratio is based on absolute compressor-outlet pressure divided by absolute compressor-inlet pressure. Manifold gauge boost divided by atmospheric pressure is not the same measurement: inlet restriction, the intercooler and pipework can produce different pressures. Use the actual compressor map and appropriate measurements to assess the operating region. Garrett compressor-map guidance.

Charge-air and turbine-temperature paths

The SC8S5031 charge-air-temperature protection describes c_tia_thr_tcha_max_sp as a temperature setpoint used by torque reduction and c_tia_thr_tcha_max as a separate maximum. lc_tia_tcha_prot selects whether the example strategy uses the upstream-throttle or downstream-compressor temperature quantity. tia_thr_lpf_tcha_prot and tqi_tia_thr_tcha_max are runtime quantities. Identify the selected location and whether the specific temperature is measured or modelled; it is not automatically turbine EGT.

In the separate turbine-overheating reference, ip_tqi_teg_max_tur_min is a minimum torque-limitation curve versus engine speed, not an exhaust-temperature target. c_teg_tur_max_tcha_deac is described as a turbine-temperature deactivation threshold in this example. Turbine temperature, exhaust temperature and charge-air temperature are different quantities; establish sensor location or model before interpreting a number.

The separate SC8S5031 lambda-based turbine-overheating reference describes ip_teg_tur_up_sp[1] as a temperature setpoint map against engine speed and cylinder-air-mass setpoint. ip_teg_tur_up_ofs_sp is a separate setpoint-reduction map with the same kinds of axes; ip_tco_cor_teg_tur_up_sp weights the offset using coolant temperature and rotary-valve setpoint. Its functional prose describes a delayed offset and lambda-controller response. These values are controller inputs rather than measured turbine temperature or a replacement turbo rating; verify the active path and any modelled temperature source on the target.

Protection coordination and diagnostics

ip_tqi_tcha_prot is an error-related torque-limitation example and ip_tqi_tcha_prot_bpa concerns a boost-actuator error; the displayed axes are engine speed and ambient pressure, with Nm output. The adjacent extracted captions can differ. state_tcha_prot is a runtime bitmask, so multiple conditions can be present together. The cited SC8S5031 example assigns bits to high exhaust temperature, actuator error and excessive charger speed; confirm the exact meanings in the matching software and logger instead of treating the combined value as a single enum. Protection coordination.

Log protection state and faults with upstream and manifold pressure targets and values, ambient pressure, wastegate request/feedback, air charge, lambda, knock and relevant temperatures and modelled speed. Check scaling and sampling. Where needed, validate the changed hardware with appropriate turbo-speed, pressure and exhaust-temperature instrumentation and the turbo manufacturer's data; measured and modelled channels should be labelled separately. Garrett system optimisation.

The Easy Wastegate vendor guide acknowledges that stock compressor estimates can mismatch a replacement turbo and that its proposed threshold changes remove the associated protection. That is a product-specific trade-off, not evidence that the replacement turbo has safe speed or temperature margin. Verify the installed feature, model and independent safeguards for the actual setup.

Launch and rolling anti-lag can create distinct exhaust and turbine heat loads. Compare the installed feature’s actual timeout and temperature source with the hardware; see launch control and rolling anti-lag.

For ambient pressure, altitude and compressor pressure-ratio examples, see Simos 18 altitude and ambient pressure effects.

For engine-out and component exhaust-temperature model definitions, see Simos 18 exhaust gas temperature modelling.

Related: wastegate and boost control · bigger turbo tuning · air charge modelling · fuel system and MPI · log diagnosis.

For coolant valve control, fan demand and afterrun, see Simos 18 cooling and thermal management.

For turbine and catalyst pressure locations, model names and restriction checks, see Simos 18 exhaust pressure modelling and restriction diagnosis.

Example from a Simos 18.1 file comparisonScope of example: A user-supplied comparison of a Simos 18.1 stock file, Stage 1 and Stage 1 pops-low, with a WinOLS CSV definition export. LTEditor identified box code 5G0906259E and software 111SC800H6G00000. The files and definitions are not publicly available, so this is a single, independently unverified file-comparison observation, not a recommended calibration. The source’s stock values matched supported byte and 16-bit entries after accounting for table transposition. Selection, runtime logic, operating conditions and checksum suitability were not independently established.In this comparison, c_n_tcha_max_sp changed from approximately 165,002 to 271,259 rpm and lc_tqi_n_tcha_sp_max from 1 to 0. Their labels and the reference above suggest a change to a torque-based turbo-speed protection path. A changed switch or threshold alone does not prove the complete runtime behavior, and an ECU model or representable value is not a component speed rating. Verify the selected logic, hardware and independent speed evidence before assessing protection margin.

Rendered revisions

Open each version to inspect formatting, tables and photographs.

Revision 7: Simos 18 turbocharger protection

Scope: Engineering identifiers below are examples from the community SC8S5031_C_OEM Simos 18.1 cross-reference unless another source is identified. Match the ECU, ASW, turbo hardware, sensor configuration, calibration, units, indices and installed patches. Some community descriptions are cross-linked incorrectly; verify against the matching definition. The named calibrations are not universal safe settings. SC8S5031 reference.

What is being protected?

Turbo speed, compressor operating range, charge-air temperature and turbine/exhaust temperature can invoke different limits and responses. A torque or pressure reduction is a coordinated output, not a diagnosis on its own. After a turbocharger or intake change, a model calibrated for the original hardware may no longer accurately describe the replacement; simply changing its protection thresholds does not establish the new turbo's physical margin.

Compressor model and speed protection

  • ip_n_tcha_stnd is a standardised turbo-speed model map in the SC8S5031 compressor-model reference. The displayed instance has reduced inlet volumetric flow (m³/s) and compressor pressure ratio axes and rpm output. n_cmpr_mdl and n_tcha_stnd are runtime calculated quantities, not independent speed measurements.
  • c_n_tcha_max_sp is a maximum turbo-speed setpoint for the documented torque-based protection. ip_n_tcha_max_sp_dif_act is a speed-related activation-threshold map. Its first axis references a speed-difference breakpoint but is marked NO_INPUT_QUANTITY; its second input is n_tcha_prot_grd. The extraction labels both axes in rpm; verify the first runtime input and the exact definitions and timing instead of inferring a gradient unit. Turbo-speed protection.
  • n_tcha_lpf_prot, n_tcha_max_sp_act, n_tcha_max_sp_tran and tqi_n_tcha_max are runtime protection values. An “actual” value in a signal name does not prove a speed sensor is installed. The representable range of a calibration is not a turbocharger's mechanical rating.

For its documented MQB applications, COBB explicitly calls Turbo Shaft Speed modelled and Maximum Turbo Speed Set Point a modelled protection value. Check what the logger actually receives and whether an independent sensor is installed and configured.

Pressure ratio and compressor operating range

ip_pq_cha_max is the example maximum compressor pressure-quotient map, with engine speed and compressor-upstream air temperature axes in the SC8S5031 application reference. The source describes other contributions to the upstream-pressure top limit, including surge, ambient-sensor and turbo-speed conditions. put_max_tcha_prot is a coordinated runtime permissible upstream-pressure value, not a calibration map. Pressure-limit calculation reference.

ip_pq_cha_surge_dl is a surge-line characteristic in the SC8S5031 surge-detection reference; its displayed breakpoint axis has reduced inlet-volume-flow units but no explicit input quantity, so confirm the target definition. The neighbouring ip_pq_cha_surge_dl_hys_pl has conflicting idle/part-load labels. lv_cap_surge is a runtime logical signal, not independent proof of physically measured surge. put_max_n_tcha_max is the runtime pressure limit resulting from the speed model in the boost-limitation reference.

Compressor pressure ratio is based on absolute compressor-outlet pressure divided by absolute compressor-inlet pressure. Manifold gauge boost divided by atmospheric pressure is not the same measurement: inlet restriction, the intercooler and pipework can produce different pressures. Use the actual compressor map and appropriate measurements to assess the operating region. Garrett compressor-map guidance.

Charge-air and turbine-temperature paths

The SC8S5031 charge-air-temperature protection describes c_tia_thr_tcha_max_sp as a temperature setpoint used by torque reduction and c_tia_thr_tcha_max as a separate maximum. lc_tia_tcha_prot selects whether the example strategy uses the upstream-throttle or downstream-compressor temperature quantity. tia_thr_lpf_tcha_prot and tqi_tia_thr_tcha_max are runtime quantities. Identify the selected location and whether the specific temperature is measured or modelled; it is not automatically turbine EGT.

In the separate turbine-overheating reference, ip_tqi_teg_max_tur_min is a minimum torque-limitation curve versus engine speed, not an exhaust-temperature target. c_teg_tur_max_tcha_deac is described as a turbine-temperature deactivation threshold in this example. Turbine temperature, exhaust temperature and charge-air temperature are different quantities; establish sensor location or model before interpreting a number.

The separate SC8S5031 lambda-based turbine-overheating reference describes ip_teg_tur_up_sp[1] as a temperature setpoint map against engine speed and cylinder-air-mass setpoint. ip_teg_tur_up_ofs_sp is a separate setpoint-reduction map with the same kinds of axes; ip_tco_cor_teg_tur_up_sp weights the offset using coolant temperature and rotary-valve setpoint. Its functional prose describes a delayed offset and lambda-controller response. These values are controller inputs rather than measured turbine temperature or a replacement turbo rating; verify the active path and any modelled temperature source on the target.

Protection coordination and diagnostics

ip_tqi_tcha_prot is an error-related torque-limitation example and ip_tqi_tcha_prot_bpa concerns a boost-actuator error; the displayed axes are engine speed and ambient pressure, with Nm output. The adjacent extracted captions can differ. state_tcha_prot is a runtime bitmask, so multiple conditions can be present together. The cited SC8S5031 example assigns bits to high exhaust temperature, actuator error and excessive charger speed; confirm the exact meanings in the matching software and logger instead of treating the combined value as a single enum. Protection coordination.

Log protection state and faults with upstream and manifold pressure targets and values, ambient pressure, wastegate request/feedback, air charge, lambda, knock and relevant temperatures and modelled speed. Check scaling and sampling. Where needed, validate the changed hardware with appropriate turbo-speed, pressure and exhaust-temperature instrumentation and the turbo manufacturer's data; measured and modelled channels should be labelled separately. Garrett system optimisation.

The Easy Wastegate vendor guide acknowledges that stock compressor estimates can mismatch a replacement turbo and that its proposed threshold changes remove the associated protection. That is a product-specific trade-off, not evidence that the replacement turbo has safe speed or temperature margin. Verify the installed feature, model and independent safeguards for the actual setup.

Launch and rolling anti-lag can create distinct exhaust and turbine heat loads. Compare the installed feature’s actual timeout and temperature source with the hardware; see launch control and rolling anti-lag.

For ambient pressure, altitude and compressor pressure-ratio examples, see Simos 18 altitude and ambient pressure effects.

For engine-out and component exhaust-temperature model definitions, see Simos 18 exhaust gas temperature modelling.

Related: wastegate and boost control · bigger turbo tuning · air charge modelling · fuel system and MPI · log diagnosis.

For coolant valve control, fan demand and afterrun, see Simos 18 cooling and thermal management.

For turbine and catalyst pressure locations, model names and restriction checks, see Simos 18 exhaust pressure modelling and restriction diagnosis.

Revision 8: Simos 18 turbocharger protection

Scope: Engineering identifiers below are examples from the community SC8S5031_C_OEM Simos 18.1 cross-reference unless another source is identified. Match the ECU, ASW, turbo hardware, sensor configuration, calibration, units, indices and installed patches. Some community descriptions are cross-linked incorrectly; verify against the matching definition. The named calibrations are not universal safe settings. SC8S5031 reference.

What is being protected?

Turbo speed, compressor operating range, charge-air temperature and turbine/exhaust temperature can invoke different limits and responses. A torque or pressure reduction is a coordinated output, not a diagnosis on its own. After a turbocharger or intake change, a model calibrated for the original hardware may no longer accurately describe the replacement; simply changing its protection thresholds does not establish the new turbo's physical margin.

Compressor model and speed protection

  • ip_n_tcha_stnd is a standardised turbo-speed model map in the SC8S5031 compressor-model reference. The displayed instance has reduced inlet volumetric flow (m³/s) and compressor pressure ratio axes and rpm output. n_cmpr_mdl and n_tcha_stnd are runtime calculated quantities, not independent speed measurements.
  • c_n_tcha_max_sp is a maximum turbo-speed setpoint for the documented torque-based protection. ip_n_tcha_max_sp_dif_act is a speed-related activation-threshold map. Its first axis references a speed-difference breakpoint but is marked NO_INPUT_QUANTITY; its second input is n_tcha_prot_grd. The extraction labels both axes in rpm; verify the first runtime input and the exact definitions and timing instead of inferring a gradient unit. Turbo-speed protection.
  • n_tcha_lpf_prot, n_tcha_max_sp_act, n_tcha_max_sp_tran and tqi_n_tcha_max are runtime protection values. An “actual” value in a signal name does not prove a speed sensor is installed. The representable range of a calibration is not a turbocharger's mechanical rating.

For its documented MQB applications, COBB explicitly calls Turbo Shaft Speed modelled and Maximum Turbo Speed Set Point a modelled protection value. Check what the logger actually receives and whether an independent sensor is installed and configured.

Pressure ratio and compressor operating range

ip_pq_cha_max is the example maximum compressor pressure-quotient map, with engine speed and compressor-upstream air temperature axes in the SC8S5031 application reference. The source describes other contributions to the upstream-pressure top limit, including surge, ambient-sensor and turbo-speed conditions. put_max_tcha_prot is a coordinated runtime permissible upstream-pressure value, not a calibration map. Pressure-limit calculation reference.

ip_pq_cha_surge_dl is a surge-line characteristic in the SC8S5031 surge-detection reference; its displayed breakpoint axis has reduced inlet-volume-flow units but no explicit input quantity, so confirm the target definition. The neighbouring ip_pq_cha_surge_dl_hys_pl has conflicting idle/part-load labels. lv_cap_surge is a runtime logical signal, not independent proof of physically measured surge. put_max_n_tcha_max is the runtime pressure limit resulting from the speed model in the boost-limitation reference.

Compressor pressure ratio is based on absolute compressor-outlet pressure divided by absolute compressor-inlet pressure. Manifold gauge boost divided by atmospheric pressure is not the same measurement: inlet restriction, the intercooler and pipework can produce different pressures. Use the actual compressor map and appropriate measurements to assess the operating region. Garrett compressor-map guidance.

Charge-air and turbine-temperature paths

The SC8S5031 charge-air-temperature protection describes c_tia_thr_tcha_max_sp as a temperature setpoint used by torque reduction and c_tia_thr_tcha_max as a separate maximum. lc_tia_tcha_prot selects whether the example strategy uses the upstream-throttle or downstream-compressor temperature quantity. tia_thr_lpf_tcha_prot and tqi_tia_thr_tcha_max are runtime quantities. Identify the selected location and whether the specific temperature is measured or modelled; it is not automatically turbine EGT.

In the separate turbine-overheating reference, ip_tqi_teg_max_tur_min is a minimum torque-limitation curve versus engine speed, not an exhaust-temperature target. c_teg_tur_max_tcha_deac is described as a turbine-temperature deactivation threshold in this example. Turbine temperature, exhaust temperature and charge-air temperature are different quantities; establish sensor location or model before interpreting a number.

The separate SC8S5031 lambda-based turbine-overheating reference describes ip_teg_tur_up_sp[1] as a temperature setpoint map against engine speed and cylinder-air-mass setpoint. ip_teg_tur_up_ofs_sp is a separate setpoint-reduction map with the same kinds of axes; ip_tco_cor_teg_tur_up_sp weights the offset using coolant temperature and rotary-valve setpoint. Its functional prose describes a delayed offset and lambda-controller response. These values are controller inputs rather than measured turbine temperature or a replacement turbo rating; verify the active path and any modelled temperature source on the target.

Protection coordination and diagnostics

ip_tqi_tcha_prot is an error-related torque-limitation example and ip_tqi_tcha_prot_bpa concerns a boost-actuator error; the displayed axes are engine speed and ambient pressure, with Nm output. The adjacent extracted captions can differ. state_tcha_prot is a runtime bitmask, so multiple conditions can be present together. The cited SC8S5031 example assigns bits to high exhaust temperature, actuator error and excessive charger speed; confirm the exact meanings in the matching software and logger instead of treating the combined value as a single enum. Protection coordination.

Log protection state and faults with upstream and manifold pressure targets and values, ambient pressure, wastegate request/feedback, air charge, lambda, knock and relevant temperatures and modelled speed. Check scaling and sampling. Where needed, validate the changed hardware with appropriate turbo-speed, pressure and exhaust-temperature instrumentation and the turbo manufacturer's data; measured and modelled channels should be labelled separately. Garrett system optimisation.

The Easy Wastegate vendor guide acknowledges that stock compressor estimates can mismatch a replacement turbo and that its proposed threshold changes remove the associated protection. That is a product-specific trade-off, not evidence that the replacement turbo has safe speed or temperature margin. Verify the installed feature, model and independent safeguards for the actual setup.

Launch and rolling anti-lag can create distinct exhaust and turbine heat loads. Compare the installed feature’s actual timeout and temperature source with the hardware; see launch control and rolling anti-lag.

For ambient pressure, altitude and compressor pressure-ratio examples, see Simos 18 altitude and ambient pressure effects.

For engine-out and component exhaust-temperature model definitions, see Simos 18 exhaust gas temperature modelling.

Related: wastegate and boost control · bigger turbo tuning · air charge modelling · fuel system and MPI · log diagnosis.

For coolant valve control, fan demand and afterrun, see Simos 18 cooling and thermal management.

For turbine and catalyst pressure locations, model names and restriction checks, see Simos 18 exhaust pressure modelling and restriction diagnosis.

Example from a Simos 18.1 file comparison

Scope of example: A user-supplied comparison of a Simos 18.1 stock file, Stage 1 and Stage 1 pops-low, with a WinOLS CSV definition export. LTEditor identified box code 5G0906259E and software 111SC800H6G00000. The files and definitions are not publicly available, so this is a single, independently unverified file-comparison observation, not a recommended calibration. The source’s stock values matched supported byte and 16-bit entries after accounting for table transposition. Selection, runtime logic, operating conditions and checksum suitability were not independently established.

In this comparison, c_n_tcha_max_sp changed from approximately 165,002 to 271,259 rpm and lc_tqi_n_tcha_sp_max from 1 to 0. Their labels and the reference above suggest a change to a torque-based turbo-speed protection path. A changed switch or threshold alone does not prove the complete runtime behavior, and an ECU model or representable value is not a component speed rating. Verify the selected logic, hardware and independent speed evidence before assessing protection margin.