Emtron SL4 is a programmable standalone ECU from Emtron Australia. Four injector and four ignition channels are listed; the SL platform has two 34-way connectors, Ethernet communication and up to 32 MB internal logging. Emtron SL4 datasheet.
Identification and configuration
Record the ECU model, serial, board revision and loaded firmware. The Emtune calibration determines the use of configurable inputs and outputs; electrical limits, ignition driver type, injector impedance and wired supplies must be checked for the actual unit. Emtron engine-management manual.
Connector pinouts
These tables reproduce the positions in Emtron's SL4 pinout. The source diagrams are viewed looking into the ECU connector. NC is the manufacturer's unconnected designation. Verify connector keying, revision, power, grounds and all limits in the original before wiring; assignments differ between models and hardware revisions.
Connector A
| Pin | Channel Name | Pin | Channel Name |
|---|---|---|---|
| A1 | Injection Channel 1 | A18 | Auxiliary Output 9 |
| A2 | Injection Channel 2 | A19 | Auxiliary Output 10 |
| A3 | Injection Channel 3 | A20 | Digital Input 1 |
| A4 | Injection Channel 4 | A21 | Digital Input 2 |
| A5 | NC | A22 | Digital Input 3 |
| A6 | NC | A23 | Digital Input 4 |
| A7 | NC | A24 | Digital Input 5 |
| A8 | NC | A25 | Digital Input 6 |
| A9 | Sensor Supply 8V | A26 | Ignition Channel 1 |
| A10 | Auxiliary Output 1 | A27 | Ignition Channel 2 |
| A11 | Auxiliary Output 2 | A28 | Ignition Channel 3 |
| A12 | Auxiliary Output 3 | A29 | Ignition Channel 4 |
| A13 | Auxiliary Output 4 | A30 | NC |
| A14 | Auxiliary Output 5 | A31 | NC |
| A15 | Auxiliary Output 6 | A32 | NC |
| A16 | Auxiliary Output 7 | A33 | NC |
| A17 | Auxiliary Output 8 | A34 | Auxiliary Output 9-10, 14V Supply |
Connector B
| Pin | Channel Name | Pin | Channel Name |
|---|---|---|---|
| B1 | ECU 14V Supply | B18 | ECU Ground |
| B2 | Sensor Supply Vref1: 5.0V | B19 | Analog Input Channel 6 |
| B3 | EFI Relay Output (Low Side 200mA) | B20 | Analog Input Channel 7 |
| B4 | Ignition Switch Input | B21 | Analog Input Channel 8 |
| B5 | Crank Index Sensor + | B22 | Analog Input Channel 9 |
| B6 | Crank Index Sensor - | B23 | Analog Input Channel 10 |
| B7 | Sync Sensor + | B24 | Knock 2 + |
| B8 | Sync Sensor - | B25 | Knock 2 - |
| B9 | Shield (Crank/Sync/ Knock) | B26 | ECU Ground |
| B10 | Analog Sensor 0V Reference | B27 | CAN 1H |
| B11 | Analog Input Channel 1 | B28 | CAN 1L |
| B12 | Analog Input Channel 2 | B29 | NC |
| B13 | Analog Input Channel 3 | B30 | NC |
| B14 | Analog Input Channel 4 | B31 | Ethernet Tx + |
| B15 | Analog Input Channel 5 | B32 | Ethernet Tx - |
| B16 | Knock 1 + | B33 | Ethernet Rx + |
| B17 | Knock 1 - | B34 | Ethernet Rx - |
Sensor 0 V references and main ECU grounds have distinct wiring requirements. H-bridge supplies and relay control require the installation described in the manufacturer's power-distribution guide. See Emtron wiring index and revision-specific diagrams.