FuelTech FT600 is a PowerFT engine-management unit. PowerFT ECU with 20 configurable inputs and 32 outputs, including support for up to 16 injector channels as configured. It integrates a display and data logging. FuelTech model documentation · FuelTech range comparison.
Identification and software
Record the exact model, serial, harness, firmware and configured outputs; similarly named FT models may use different connectors and functions. Tuning software: FTManager. FuelTech software and compatibility.
Wiring and pinout
Use the model-specific manual and the current FuelTech manuals index for connector view, cavity numbering, fuse values, sensor grounds and injector-driver limits. The manufacturer wiring archive contains installation-specific examples; match the exact ECU and harness before wiring. Pin functions depend on the model, hardware and configured output.
See FuelTech engine-management family for other models and company background. FuelTech is based in Brazil and has a US operation in Georgia. Sources reviewed 17 November 2026.
FT600 ECU connector pin assignments
The FuelTech FT600 manual, sections 4.3 and 4.4, identifies two 34-way ECU connectors. The listed sensor and output functions are configurable; use the exact revision and check the connector view, driver ratings, protection and ground routing in the original. The magnetic trigger references are not generic Hall sensor grounds.
Connector A — 34 way
| Pin | Function and harness wire |
|---|---|
| 1 | Blue output #1 (blue #1) |
| 2 | Blue output #2 (blue #2) |
| 3 | Blue output #3 (blue #3) |
| 4 | Blue output #4 (blue #4) |
| 5 | Blue output #5 (blue #5) |
| 6 | Blue output #6 (blue #6) |
| 7 | Blue output #7 (blue #7) |
| 8 | Blue output #8 (blue #8) |
| 9 | Blue output #9 (blue #9) |
| 10 | Blue output #10 (blue #10) |
| 11 | Blue output #11 (blue #11) |
| 12 | Blue output #12 (blue #12) |
| 13 | Blue output #13 (blue #13) |
| 14 | Blue output #14 (blue #14) |
| 15 | Blue output #15 (blue #15) |
| 16 | Blue output #16 (blue #16) |
| 17 | Power ground (black/white) |
| 18 | Gray output #1 (gray #1) |
| 19 | Gray output #2 (gray #2) |
| 20 | Gray output #3 (gray #3) |
| 21 | Gray output #4 (gray #4) |
| 22 | Gray output #5 (gray #5) |
| 23 | Gray output #6 (gray #6) |
| 24 | Gray output #7 (gray #7) |
| 25 | Gray output #8 (gray #8) |
| 26 | Yellow output #1 (yellow #1) |
| 27 | Yellow output #2 (yellow #2) |
| 28 | Yellow output #3 (yellow #3) |
| 29 | Yellow output #4 (yellow #4) |
| 30 | Yellow output #5 (yellow #5) |
| 31 | Yellow output #6 (yellow #6) |
| 32 | Yellow output #7 (yellow #7) |
| 33 | Yellow output #8 (yellow #8) |
| 34 | 12 V input from main relay (red) |
Connector B — 34 way
| Pin | Function and harness wire |
|---|---|
| 1 | RPM signal input (red) |
| 2 | Magnetic RPM sensor reference (white) |
| 3 | Cam sync signal input (red) |
| 4 | Cam sync reference input (white) |
| 5 | White input #1 |
| 6 | White input #2 |
| 7 | White input #3 |
| 8 | White input #4 |
| 9 | White input #5 |
| 10 | Battery negative (black) |
| 11 | CAN A low (yellow/blue) |
| 12 | CAN A high (white/red) |
| 13 | White input #6 |
| 14 | White input #7 |
| 15 | White input #8 |
| 16 | White input #9 |
| 17 | White input #10 |
| 18 | Power ground (black/white) |
| 19 | Power ground (black/white) |
| 20 | CAN B high (white/red) |
| 21 | White input #11 |
| 22 | White input #12 |
| 23 | White input #13 |
| 24 | White input #14 |
| 25 | White input #15 |
| 26 | 12 V input from main relay (red) |
| 27 | 5 V sensor supply (green/red) |
| 28 | CAN B low (yellow/blue) |
| 29 | Sensor ground (green/black) |
| 30 | White input #16 |
| 31 | White input #17 |
| 32 | White input #18 |
| 33 | White input #19 / Power Shift positive |
| 34 | White input #20 / Power Shift negative |
Use the manual's power, grounding, relay and sensor instructions; power-ground and sensor-ground circuits have different functions. The optional Power Shift uses input channels 19 and 20 on this model.