Link G4X MonsoonX is a programmable G4X wire-in engine-management ECU. One A loom; the manufacturer guide states that knock hardware on pin 6 requires version 3 or newer. Link G4X MonsoonX quick-start guide.
Model identification and I/O
| Item | Documented details |
|---|---|
| ECU family | G4X |
| Outputs | 4 injection and 4 ignition drives |
| Programming | PCLink version matched to ECU generation and firmware |
| Connector and loom | See the exact-model guide, including connector keys, wire-side orientation and optional functions |
The manufacturer guidance and wiring identify the hardware; driver counts do not establish injector electrical compatibility or imply all multiplexed pins can be used at the same time.
Model-specific pinout and installation
The G4X MonsoonX quick-start guide provides the connector diagrams and installer I/O table. Refer to that version for numbered cavities, wire colours, supply, grounds, driver and sensor connection notes. Loom wire-side and ECU header views are identified on the diagram; do not transfer a pin number from another generation.
The Link manufacturer page also contains a transcribed G4X MonsoonX 34-way table. Hardware version affects the pin 6 knock input.
Complete loom connector tables
The following positions are transcribed from the Link MONSOONX quick-start guide. They are viewed into the ECU header or the wire side of the loom, as illustrated in the source. Unlabelled positions are shown as such, rather than assumed unused. Colours apply to the documented loom; outputs and shared functions depend on ECU hardware version and configuration. Refer to the original for keying, current limits and full installation diagrams.
A/B loom connector A — 34-way
| Pin | Function in guide | Loom colour |
|---|---|---|
| 1 | Injector 4 | Brown/Orange |
| 2 | Injector 3 | Brown/Red |
| 3 | Injector 2 | Brown |
| 4 | Injector 1 | Brown/Black |
| 5 | +14 V | Red |
| 6 | Digital input 4 / knock (knock requires version 3 or newer) | Red/White |
| 7 | Shield/Ground | Green |
| 8 | Trigger 1 | Black |
| 9 | Trigger 2 | Red |
| 10 | Ignition 4 | Blue/Orange |
| 11 | Ignition 3 | Blue/Red |
| 12 | Ignition 2 | Blue/Brown |
| 13 | Ignition 1 | Blue |
| 14 | Analogue voltage 4 | White/Black |
| 15 | Temperature 1 | Yellow |
| 16 | Temperature 2 | Yellow/Brown |
| 17 | Analogue voltage 1 | Yellow/Blue |
| 18 | Auxiliary 4 | Orange |
| 19 | Auxiliary 3 | Orange/Red |
| 20 | Auxiliary 2 | Orange/Brown |
| 21 | Auxiliary 1 | Orange/Black |
| 22 | Analogue voltage 2 | White/Brown |
| 23 | Digital input 3 | Grey/Red |
| 24 | Ground out | Green |
| 25 | Ground | Black |
| 26 | Auxiliary 6 | Orange/Purple |
| 27 | Auxiliary 5 | Orange/Blue |
| 28 | CAN high | Orange/Green |
| 29 | CAN low | Orange/Yellow |
| 30 | Digital input 1 | Grey/Black |
| 31 | Digital input 2 | Grey/Brown |
| 32 | +5 V | Red/Blue |
| 33 | Analogue voltage 3 | Yellow/Black |
| 34 | Ground | Black |
Software and further sources
Download software, firmware and full installation help from Link's download centre; identify the ECU generation and installed firmware before choosing a PCLink package. The legacy software list separates G5, G4X and G4+ compatibility. See also Link standalone ECUs.