The ME360 GEN2 is a programmable fuel-and-ignition ECU for six fully sequential cylinders or complex four-cylinder applications including drive-by-wire, as described in ME's GEN2 installation guide. It adds EGT and electronic-throttle functions relative to the ME221. The manufacturer lists CAN, wideband sensing, configurable inputs and outputs and logging; electrical and firmware configurations must match the engine. Manufacturer documentation · ME manuals and downloads.
Identification and configuration
Record the complete model label, serial number, hardware generation, firmware and harness. Wire-in ECUs and vehicle-specific plug-in versions have different physical connections. Software and output assignments depend on the unit and calibration; follow the appropriate manufacturer wiring guide and check the installed configuration.
The manufacturer's ME360 category page also uses an eight-cylinder phrase; its GEN2 quick guide and comparison specify six fully sequential cylinders. Confirm the intended cylinder and ignition arrangement with ME before selection rather than treating those descriptions as equivalent.
GEN2 90-way connector pinout
The manufacturer GEN2 wiring reference documents a common 90-way connector with model-specific channel availability. The final column is the manufacturer's ME360 availability; “NO” means the function is not available on this variant. Establish the connector view from the original diagram and confirm actual hardware, configured I/O, current limits and fuses. This is not the earlier REV C/D ME442 pinout.
| Pin | Function | Manufacturer note | ME360 available |
|---|---|---|---|
| 1 | COIL 4 | IGBT or 5V TTL (Software Selectable) | YES |
| 2 | COIL 3 | IGBT or 5V TTL (Software Selectable) | YES |
| 3 | INJECTOR 4 | 2A CONSTANT PROTECTED (6ohm Min Hi Imp) | YES |
| 4 | INJECTOR 2 | 2A CONSTANT PROTECTED (6ohm Min Hi Imp) | YES |
| 5 | DIG_IN 4 | PULLED HIGH WEAK 5V | YES |
| 6 | DIG_IN 1 | PULLED HIGH WEAK 5V | YES |
| 7 | DIG_IN 2 | PULLED HIGH WEAK 5V | YES |
| 8 | DIG_IN 3 | PULLED HIGH WEAK 5V | YES |
| 9 | LOW SIDE RELAY 18 | 100mA Relay Driver | YES |
| 10 | GROUND CHASSIS | GROUNDS (CHASSIS) | YES |
| 11 | EGT 1 | EGT 1 | YES |
| 12 | LOW SIDE 2 | 2.5A PWM-ABLE | YES |
| 13 | LOW SIDE RELAY 15 | 100mA Relay Driver | YES |
| 14 | VBAT IGNITION | VOLTAGE SUPPLY (SWITCHED 12V IGNITION) Linked internally to Pin 15 below. | YES |
| 15 | LSU HEATER +VE | Wideband Connection (LSU4.9) | YES |
| 16 | LSU HEATER -VE | Wideband Connection (LSU4.9) | YES |
| 17 | ANA VOLT 3 | 0-5V ANALOG PROTECTED INPUT | YES |
| 18 | ANA VOLT 4 | 0-5V ANALOG PROTECTED INPUT | YES |
| 19 | LSU UN | Wideband Connection (LSU4.9) | YES |
| 20 | LSU VM | Wideband Connection (LSU4.9) | YES |
| 21 | CAN 1 HIGH | CAN 1 HIGH | YES |
| 22 | CAM A VR+ | YES | |
| 23 | CAM A VR- | YES | |
| 24 | SERIAL 1 GROUND | SERIAL COMMS GROUND | YES |
| 25 | SERIAL 1 TX | SERIAL COMMS TRANSMIT RS232 LEVEL | YES |
| 26 | ANA VOLT 1 | 0-5V ANALOG PROTECTED INPUT | YES |
| 27 | INJECTOR 8 | 2A CONSTANT PROTECTED (6ohm Min Hi Imp) | NO |
| 28 | INJECTOR 5 | 2A CONSTANT PROTECTED (6ohm Min Hi Imp) | YES |
| 29 | COIL 7 | IGBT or 5V TTL (Software Selectable) | NO |
| 30 | COIL 8 | IGBT or 5V TTL (Software Selectable) | NO |
| 31 | COIL 2 | IGBT or 5V TTL (Software Selectable) | YES |
| 32 | COIL 1 | IGBT or 5V TTL (Software Selectable) | YES |
| 33 | INJECTOR 3 | 2A CONSTANT PROTECTED (6ohm Min Hi Imp) | YES |
| 34 | DIG_IN 6 | PULLED HIGH WEAK 5V | YES |
| 35 | USB D+ | YES | |
| 36 | USB D- | YES | |
| 37 | LOW SIDE RELAY 11 | 100mA Relay Driver | YES |
| 38 | USB VBUS | YES | |
| 39 | LOW SIDE 6 | 2.5A PWM-ABLE | YES |
| 40 | LOW SIDE RELAY 17 | 100mA Relay Driver | YES |
| 41 | USB GROUND | YES | |
| 42 | LOW SIDE RELAY 12 | 100mA Relay Driver | YES |
| 43 | LOW SIDE RELAY 14 | 100mA Relay Driver | YES |
| 44 | LOW SIDE 4 | 2.5A PWM-ABLE | YES |
| 45 | 5V REF | 200mA MAX 5V SENSOR SUPPLY | YES |
| 46 | 5V REF | 200mA MAX 5V SENSOR SUPPLY | YES |
| 47 | ANA TEMP 4 | THERMISTOR INPUT PULLED TO 5V via 2K7 | NO |
| 48 | ANA VOLT 7 | 0-5V ANALOG PROTECTED INPUT | NO |
| 49 | LSU IA | Wideband Connection (LSU4.9) | YES |
| 50 | LSU IP | Wideband Connection (LSU4.9) | YES |
| 51 | CAN 1 LOW | CAN 1 LOW | YES |
| 52 | SENSORS GROUND | SENSOR & COMMS GROUND AND VR SHEILDS | YES |
| 53 | KNOCK 1 SIGNAL | KNOCK DSP 1 | YES |
| 54 | KNOCK 2 SIGNAL | KNOCK DSP 2 | NO |
| 55 | SERIAL 1 RX | SERIAL COMMS RECIEVE RS232 LEVEL | YES |
| 56 | ANA VOLT 2 | 0-5V ANALOG PROTECTED INPUT | YES |
| 57 | ANA TEMP 2 | THERMISTOR INPUT PULLED TO 5V via 2K7 | YES |
| 58 | INJECTOR 6 | 2A CONSTANT PROTECTED (6ohm Min Hi Imp) | YES |
| 59 | COIL 5 | IGBT or 5V TTL (Software Selectable) | YES |
| 60 | COIL 6 | IGBT or 5V TTL (Software Selectable) | YES |
| 61 | GROUND | POWER GROUND TO CHASSIS | YES |
| 62 | DIG_IN 5 | PULLED HIGH WEAK 5V | YES |
| 63 | INJECTOR 1 | 2A CONSTANT PROTECTED (6ohm Min Hi Imp) | YES |
| 64 | VBAT | BATTERY VOLTAGE SUPPLY (SWITCHED IGNITION) | YES |
| 65 | H-BRIDGE A OUT 1 | DBW H-BRIDGE | YES |
| 66 | H-BRIDGE A OUT 2 | DBW H-BRIDGE | YES |
| 67 | Stepper 1 / A1 | 500mA H-Bridge | YES |
| 68 | Stepper 2 / A2 | 500mA H-Bridge | YES |
| 69 | LOW SIDE 5 | 2.5A PWM-ABLE | YES |
| 70 | Stepper 3 / B1 | 500mA H-Bridge | YES |
| 71 | Stepper 4 / B2 | 500mA H-Bridge | YES |
| 72 | LOW SIDE RELAY 13 | 100mA Relay Driver | YES |
| 73 | LOW SIDE 1 | 2.5A PWM-ABLE | YES |
| 74 | LOW SIDE 3 | 2.5A PWM-ABLE | YES |
| 75 | LOW SIDE RELAY 16 | 100mA Relay Driver | YES |
| 76 | 5V REF | 250mA MAX 5V SENSOR SUPPLY | YES |
| 77 | ANA TEMP 3 | THERMISTOR INPUT PULLED TO 5V via 2K7 | YES |
| 78 | ANA VOLT 6 | 0-5V ANALOG PROTECTED INPUT | NO |
| 79 | TACHOMETER | 200mA 12V PWM-ABLE | YES |
| 80 | CRANK VR+ | YES | |
| 81 | CRANK VR- | YES | |
| 82 | CAM B VR+ | YES | |
| 83 | CAM B VR- | YES | |
| 84 | Sensor Ground | Use for Crank Sensor Shields (Typically) | YES |
| 85 | NOT USED | NOT USED | N/A |
| 86 | ANA TEMP 1 | THERMISTOR INPUT PULLED TO 5V via 2K7 | YES |
| 87 | ANA VOLT 5 | 0-5V ANALOG PROTECTED INPUT | NO |
| 88 | INJECTOR 7 | 2A CONSTANT PROTECTED (6ohm Min Hi Imp) | NO |
| 89 | GROUND | POWER GROUND TO CHASSIS | YES |
| 90 | GROUND | POWER GROUND TO CHASSIS | YES |
Software and further information
ME provides MEITE / EZ Tune, firmware and installation guides on its support page. Confirm the software and firmware required by the actual unit. See Motorsport Electronics ECU family.