Tuning Wiki
Link G4X StormX ECU
G4X StormX manufacturer photograph: Link ECU. Permission to republish confirmed by the user.

Link G4X StormX is a programmable G4X wire-in engine-management ECU. The manufacturer lists eight digital, eight analogue and three temperature inputs, two knock inputs, a CAN bus and 512 MB logging. Sequential injection and direct spark support extends to eight cylinders when configured appropriately. Link G4X StormX quick-start guide.

Model identification and I/O

ItemDocumented details
ECU familyG4X
Outputs8 injection and 8 ignition drives
ProgrammingPCLink version matched to ECU generation and firmware
Connector and loomSee the exact-model guide, including connector keys, wire-side orientation and optional functions

The manufacturer guidance and wiring identify the hardware; driver counts do not establish injector electrical compatibility or imply all multiplexed pins can be used at the same time.

Model-specific pinout and installation

The G4X StormX quick-start guide provides the connector diagrams and installer I/O table. Refer to that version for numbered cavities, wire colours, supply, grounds, driver and sensor connection notes. Loom wire-side and ECU header views are identified on the diagram; do not transfer a pin number from another generation.

Complete loom connector tables

The following positions are transcribed from the Link STORMX quick-start guide. They are viewed into the ECU header or the wire side of the loom, as illustrated in the source. Unlabelled positions are shown as such, rather than assumed unused. Colours apply to the documented loom; outputs and shared functions depend on ECU hardware version and configuration. Refer to the original for keying, current limits and full installation diagrams.

A/B loom connector A — 34-way

PinFunction in guideLoom colour
1Injector 4Brown/Orange
2Injector 3Brown/Red
3Injector 2Brown
4Injector 1Brown/Black
5+14 VRed
6+8 VRed/White
7Shield/GroundGreen
8Trigger 1Black
9Trigger 2Red
10Ignition 4Blue/Orange
11Ignition 3Blue/Red
12Ignition 2Blue/Brown
13Ignition 1Blue
14Analogue voltage 4White/Black
15Temperature 1Yellow
16Temperature 2Yellow/Brown
17Analogue voltage 1Yellow/Blue
18Auxiliary 4Orange
19Auxiliary 3Orange/Red
20Auxiliary 2Orange/Brown
21Auxiliary 1Orange/Black
22Analogue voltage 2White/Brown
23Digital input 3Grey/Red
24Ground outGreen
25GroundBlack
26Auxiliary 8Orange/Purple
27Auxiliary 7Orange/Blue
28Auxiliary 6Orange/Green
29Auxiliary 5Orange/Yellow
30Digital input 1Grey/Black
31Digital input 2Grey/Brown
32+5 VRed/Blue
33Analogue voltage 3Yellow/Black
34GroundBlack

A/B loom connector B — 34-way

PinFunction in guideLoom colour
1Injector 8Brown/Purple
2Injector 7Brown/Blue
3Injector 6Brown/Green
4Injector 5Brown/Yellow
5Not labelled in guide—
6Temperature 3Yellow/Red
7Not labelled in guide—
8Knock 2White
9Knock 1White
10Ignition 8Blue/Purple
11Ignition 7Blue/Black
12Ignition 6Blue/Green
13Ignition 5Blue/Yellow
14Not labelled in guide—
15Analogue voltage 6White/Red
16Analogue voltage 7White/Orange
17Shield/GroundGreen
18Not labelled in guide—
19Digital input 6Grey/Green
20Digital input 5Grey/Yellow
21Digital input 4Grey/Orange
22Ground outGreen
23Analogue voltage 8White/Yellow
24Not labelled in guide—
25GroundBlack
26Not labelled in guide—
27CAN 2 highGrey/Purple
28CAN 2 lowGrey/White
29Digital input 8Grey
30Digital input 7Grey/Blue
31Not labelled in guide—
32Not labelled in guide—
33Analogue voltage 5Yellow/Green
34GroundBlack

Software and further sources

Download software, firmware and full installation help from Link's download centre; identify the ECU generation and installed firmware before choosing a PCLink package. The legacy software list separates G5, G4X and G4+ compatibility. See also Link standalone ECUs.

Directly applicable articles

Technical articles assigned to this context will appear here.