Tuning Wiki

Cosworth Pectel SQ7Di engine control unit

Product photograph: Cosworth. Used with permission.

Cosworth Pectel motorsport ECUs include configurable engine and powertrain control. Product features, software permissions and championship configurations can vary.

Models

  • Historic Pectel T10s; Cosworth identifies MQ12 as its replacement in 2008.
  • SQ6, SQ6M and SQ6M12.
  • MQ12 and MQ12Di.
  • SQ7Di, a direct-injection ECU for up to six cylinders.

Evidence: MQ12 product page and Cosworth product archive; SQ7Di product page includes a product image. IDU1 is an injection driver, not a standalone ECU.

Individual model references

Follow each model link for scope, sources and connector information. Similar model names do not establish compatible pinouts or software.

Choosing and identifying Cosworth controllers

ModelIdentification and documented differencesSource
T2Historic four-cylinder controller; period Pectel sheet describes four high-impedance injector drivers and two ignition channels.Pectel sheet mirror
T6Earlier controller; AiM documents a 55-position connector and RS232 link.AiM T2/T6
T10sEarlier range-topping ECU; Cosworth dates its MQ12 replacement to 2008.MQ12 history
SQ612 injector, eight IGBT and eight logic ignition drivers; 88-way connector.SQ6 sheet and pinout
SQ6M12 injector, eight IGBT and eight logic ignition outputs; Autosport connectors and 4 MB logging. Optional paddle shift.SQ6M
SQ6M1212 peak-and-hold injector, 12 IGBT and four logic ignition outputs; suitable for one to twelve cylinders.SQ6M12 sheet and pinouts
SQ7DiIntegrated direct injection driver and ECU, six boosted GDI outputs; two low-side injector outputs.SQ7Di sheet and pinouts
MQ1220 configurable injector/PWM, 12 IGBT and 16 logic ignition outputs; up to twelve-cylinder fuelling.MQ12 sheet and pinouts
MQ12DiGDI/port or combined control; the manufacturer identifies it as a successor development to separate MQ12 and IDU1 hardware.MQ12Di
Antares 4 / 6 / 8Cosworth CHP2-based family with multiple I/O, logging and configuration options. Product-specific outputs and available features vary; two manufacturer documents give different Antares 4/6 counts, so verify the exact build.Family overview · Antares 8 sheet

Software and supported options

Hardware drivers can be shared or have build-specific electrical limits. Cosworth documents optional strategies, championship locking, and application-specific software on different products. Antares uses Pi Caltool for calibration, Pi Toolbox for analysis and Pi Toolset for logging/device configuration; selected Antares variants support additional Auto Coding. Cosworth software descriptions and Pectel application notes.

Pectel SQ6 — 88-way connector

For SQ6 part 01E-500700 / gearbox upgrade 01E-500700-E011, product information 29E-071516-4E; diagram is view looking into the 88-way connector. The source identifies higher-current pins using shading; consult it for ratings and alternate functions. SQ6 product information and diagram

PinFunction
12, 13, 72, 73, 40, 42, 43, 14, 15, 16AIN1–AIN10 respectively
71, 41, 70TC1 positive, TC2 positive, TC negative
68, 38, 69, 39Lambda V1, current pump 1, V2, current pump 2
10, 11Knock DET1, DET2
46, 18, 17Crank 1, crank 2, cam
78, 77, 48, 21, 20, 47, 19, 76Digital inputs 1–8 respectively
36, 66RS232 TX, RX
75, 45, 74, 44Ethernet TX+, TX−, RX+, RX−
37, 67, 8, 9CAN1 low, CAN1 high, CAN2 low, CAN2 high
55, 88, 87, 86, 85, 54, 84, 52, 83, 82, 81, 80Injector outputs 1–12 respectively
26, 25, 22, 28, 27, 53, 51, 50IGBT ignition outputs 1–8 respectively
56–63Logic-level ignition outputs 1–8 respectively
34, 6, 33, 2, 4, 31PWM outputs 1–6 respectively
30, 5, 1, 29H-bridge HB1A, HB1B, HB2A, HB2B
32, 3H-bridge HB3A, HB3B
65, 64Programmable 5 V / 12 V sensor supplies
35, 7, 79Analogue ground, crank/cam ground, digital ground
24, 23ECU battery negative, engine ground
49ECU battery positive

Other units use different connectors: SQ6M12 connector pinout and SQ7Di pinout.

Confirm the exact ECU, hardware revision and connector orientation before wiring. Configurable functions and electrical limits are model-dependent; consult the linked original diagrams.