Scope: Unless a product or other software is named, engineering identifiers are examples from the community SC8S5031_C_OEM Simos 18.1 reference. Verify the actual ECU/ASW, sensor arrangement, definitions, units, indices, selectors and installed patches. Some extracted function captions conflict with the A2L labels; names, addresses or numbers cannot be transferred blindly. SC8S5031 reference.
Request, model and physical measurement
The air charge used in torque and fuel calculations is a cylinder-air quantity, often displayed as mg per stroke. The ECU combines its pressure, temperature, speed and engine-state information with models; a calculated cylinder charge is not necessarily a direct air-mass sensor measurement. Driver torque request, the air-mass setpoint, estimated cylinder charge and manifold or upstream-throttle pressure are distinct. EcuTek describes an air setpoint as part of the slow torque path in its EA888 guide.
Torque-to-air and limit examples
ip_maf_stk_sp_vvl_cam_h[1][2][1] and ip_maf_stk_sp_vvl_cam_l[1][2][1] are example torque-based air-setpoint maps: engine speed and indicated torque to air mass per stroke. The selected flap, valve-lift and cam states matter. Their related ip_tqi_ref_n_m_air_vvl_cam_h/l families perform a different, reference-torque calculation using speed and cylinder air mass. Corrections and transients prevent assuming the two families are exact inverses in all conditions. TQDR air setpoint; reference torque.
The INSY air-mass limits reference lists ip_m_air_cyl_max_stnd_vvl[1] as a standardised maximum intake-air curve versus speed for a lift case, output mg/stroke. ip_fac_m_air_cyl_max_amp_cor_1[1] and ip_fac_m_air_cyl_max_tia_cor_1[1] are ambient-pressure and intake-temperature correction-factor examples. Their displayed instance has one breakpoint on each axis and the extracted temperature caption conflicts; verify the actual definition and do not assume a full-sized map. m_air_cyl_max_cor_vvl[1] and ratio_m_air_cyl_max are runtime values, not calibration tables. A flat displayed value alone may be a channel or scaling limit rather than an active ECU limit.
Volumetric efficiency and combustion corrections
The combustion-condition reference identifies ip_fac_maf_cor[3] as an array-selectable standardised air-mass correction factor, with speed and manifold pressure axes in the example. Its adjacent extracted caption conflicts; check the selector and software. ip_eff_vol_ofs_iga_cor_stnd[5] and ip_eff_vol_ofs_iga_cor_vlft_1[5] are ignition-related air-mass offsets for different lift cases, with air-mass and ignition-angle-difference axes and an additional speed dimension described by the source. They are model corrections, not ignition targets.
ip_eff_vol_fac_prs_ex_ratio_ref[1] is an exhaust-pressure-ratio-related model adjustment factor; it is not a direct measured exhaust pressure. eff_vol_slop_stk_1[0][1] and eff_vol_ofs_stk_1[0][1] are runtime slope and offset results. Forward pressure-to-charge and inverse charge-to-pressure paths depend on the actual operating mode and corrections. INSY volumetric-efficiency coordination.
Manifold prediction and scavenging
In the INSY mass-air calculation, ip_fac_prs_im_pred is a manifold-pressure prediction factor against rpm and dynamic throttle pressure ratio. ip_vo_eff_scav_1 represents effective overlap for the scavenging model against intake/exhaust cam position, with crank-angle output. Neither is a standalone boost-target map. Runtime examples include prs_im_pred (predicted manifold pressure), m_air_cyl_ign_1 (delayed fresh-gas mass) and mfl_thr_tps_av_1 (calculated throttle flow). The target definition and logger must establish whether a value is measured, estimated or filtered.
The same mass-air reference also lists ip_fac_prs_im_pred_mpi for an MPI configuration, with rpm and dynamic throttle-pressure-ratio axes. Its copied functional-description caption instead refers to gaseous fuel, so verify the active selector and exact image; the separate ip_fac_prs_im_pred_gas is described for gas fuel. ip_m_scav_bas_1[3] is a basic scavenged-air-mass map array in mg/stroke against effective valve overlap and a pressure-ratio axis. The latter is marked NO_INPUT_QUANTITY; establish the actual pressure inputs and array selection before interpreting it. ip_m_scav_inc_max[3] is a speed-dependent positive-difference limit on that model. These are model quantities, not a direct measurement of air escaping the cylinder or a standalone cam-timing target. SC8S5031 INSY mass-air and scavenging definitions.
Pressure targets and validation
COBB's MQB guide uses the product labels Maximum Torque Manual/Automatic, Mass Air Setpoint for Torque Intervention and Pressure Up Throttle Setpoint. In its Golf R example the upstream-pressure table is a ceiling; the guide describes a different presentation for its GTI example. These are tool labels and application-specific descriptions, not a single guaranteed calculation for every Simos 18.
Compare requested and estimated air mass, torque request and active limits, manifold and upstream-throttle pressure and their respective setpoints, ambient conditions, cam/lift/flap states, fuel and ignition. COBB MQB monitor definitions distinguish Air Mass Intake Manifold Per Stroke, Air Mass Per Stroke Set Point, PUT Set Point, Intake Manifold Pressure Set Point and individual Mass Flow Limit for Torque Intervention channels. Its Charge Air Temperature and Turbo Shaft Speed examples are modelled and its Boost Pressure is gauge. Confirm availability, units, sensor scaling, absolute versus gauge pressure and sampling for the actual tool. Resolve sensor, leak or actuator faults before attributing a mismatch to a calibration.
For compressor speed, pressure-ratio and temperature limits, see Simos 18 turbocharger protection.
For pressure sensor conversion and charge-temperature modelling, see MAP and boost pressure sensors and intake air temperature and charge modelling.
Vapour and ventilation guides: EVAP purge · crankcase ventilation.
For flap setpoint maps, position feedback and adaptation checks, see Simos 18 intake manifold runner flap control and diagnosis.
Related: air charge modelling · throttle control · torque model · wastegate and boost · camshaft timing · valve lift · log diagnosis.
For pre-turbo restriction, airflow tests and air-cleaner model examples, see Simos 18 intake and turbo inlet upgrades.