Overview and hardware
Syvecs S7Plus is a British engine-management ECU. 22 inputs, 16 injector/low-side outputs, 6 ignition outputs, 8 half bridges, 2 wideband and 2 knock inputs, 94 pins, 6–20 V. Two ordinary CAN interfaces; a third shares EGT1 resources and is reserved for custom Syvecs applications. EGT availability depends on resource allocation.
Compare the required injector, ignition, actuator and sensor channels with the hardware available on the actual ECU. Capabilities and configurable functions depend on firmware, hardware revision and calibration.
Wiring and pinout
Manufacturer S7Plus wiring guide and pinout. Use the guide's connector view and pin numbering and verify ECU hardware revision and configuration before wiring. Pin and input functions may vary by calibration or vehicle. Syvecs wiring index contains further example pinout files.
Vehicle-specific replacement kits use their own harness or carrier board. Consult the corresponding vehicle-specific Syvecs guide rather than assuming a generic schedule applies.
Complete connector pin assignments
All 94 positions below follow the Syvecs S7PLUS model-specific wiring guide, using the guide's source labels. N/A reproduces a source-marked unavailable position. Pin names describe hardware channels; assignments, software configuration, connector orientation, hardware options and electrical limits must be checked in that guide for the exact ECU.
Connector A
| Pin | Source label |
|---|---|
| A1 | PWR CTR OUT |
| A2 | H-Bridge1 / SlaveOut1 |
| A3 | H-Bridge2/ SlaveOut2 |
| A4 | H-Bridge3 / SlaveOut3 |
| A5 | H-Bridge4 / SlaveOut4 |
| A6 | H-Bridge5 / SlaveOut5 |
| A7 | H-Bridge6 / SlaveOut6 |
| A8 | H-Bridge7 / SlaveOut7 |
| A9 | H-Bridge8 / SlaveOut8 |
| A10 | FUEL1 |
| A11 | FUEL2 |
| A12 | FUEL3 |
| A13 | FUEL4 |
| A14 | FUEL5 |
| A15 | FUEL6 |
| A16 | FUEL7 |
| A17 | FUEL8 |
| A18 | FUEL9/PWM1 |
| A19 | FUEL10/PWM2 |
| A20 | FUEL11/PWM3 |
| A21 | FUEL12/PWM4 |
| A22 | FUEL13/PWM5 |
| A23 | FUEL14/PWM6 |
| A24 | FUEL15/PWM7 |
| A25 | FUEL16/PWM8 |
| A26 | IGN1 |
| A27 | IGN2 |
| A28 | IGN3 |
| A29 | IGN4 |
| A30 | IGN5 |
| A31 | IGN6 |
| A32 | PWRGND |
| A33 | PWRGND |
| A34 | PWRGND |
Connector B
| Pin | Source label |
|---|---|
| B1 | PWRGND |
| B2 | CAN2 L |
| B3 | CAN2 H |
| B4 | KNOCK |
| B5 | KNOCK 2 |
| B6 | PVBAT |
| B7 | VBAT |
| B8 | LAM1A |
| B9 | LAM1B |
| B10 | LAM1C |
| B11 | LAM1D |
| B12 | LAM1HEATER |
| B13 | VBAT |
| B14 | LAM2A |
| B15 | LAM2B |
| B16 | LAM2C |
| B17 | LAM2D |
| B18 | LAM2HEATER |
| B19 | VBAT |
| B20 | KLINE |
| B21 | RS232RX |
| B22 | RS232TX |
| B23 | LANRX- |
| B24 | LANRX+ |
| B25 | LANTX- |
| B26 | LANTX+ |
Connector C
| Pin | Source label |
|---|---|
| C1 | KNOCK GROUNDS |
| C2 | ANGND |
| C3 | ANGND |
| C4 | ANGND |
| C5 | 5V OUT |
| C6 | 5V OUT |
| C7 | 5V OUT |
| C8 | CAN L |
| C9 | CAN H |
| C10 | AN01 |
| C11 | AN02 |
| C12 | AN03 |
| C13 | AN04 |
| C14 | AN05 |
| C15 | AN06 |
| C16 | AN07 |
| C17 | AN08 |
| C18 | AN09 |
| C19 | AN10 |
| C20 | AN11 |
| C21 | AN12 |
| C22 | AN13 |
| C23 | AN14 |
| C24 | AN15 |
| C25 | AN16 |
| C26 | EGT1- / Can 3 L |
| C27 | EGT1+ / Can 3 H |
| C28 | PWR CTR IN |
| C29 | AN S1 / Slave An01 |
| C30 | AN S2 / Slave An02 |
| C31 | AN S3 / Slave An03 |
| C32 | AN S4 / Slave An04 |
| C33 | AN S5 / Slave An05 |
| C34 | AN S7 / Slave An06 |
Calibration and sources
Syvecs uses SCal calibration software and provides firmware and base calibrations. Check version compatibility with the unit and preserve the existing tune before changes.