Tuning Wiki

MaxxECU MINI — Compact entry ECU with four injector and four ignition outputs; up to four fully sequential cylinders or eight in wasted spark. MaxxECU product information.

MaxxECU MINI
MaxxECU MINI, manufacturer product image: MaxxECU. Used with permission.

Model identification and capabilities

A 400 kPa absolute MAP sensor is built in. The MINI has one VR/Hall trigger, two extra Hall/digital inputs and two extra 0–5 V analogue inputs in addition to its named temperature and throttle inputs. The manufacturer specifies four auxiliary outputs and 8 MB of internal logging, up to 1000 Hz. CAN and USB are available. Manufacturer specification; MaxxECU model comparison.

Sequential cylinders, maximum4
Injector outputs4 high-impedance
Ignition outputs4
ConfigurationMTune; check the release appropriate to the ECU and hardware revision

Identification and installation

It does not include an internal wideband controller: use the documented external analogue or CAN solution. Injector outputs are intended for high-impedance injectors; observe the manufacturer’s instructions for low-impedance injectors and external current limiting.

Record the model label, serial number, hardware revision, firmware, connector keying and loom. Outputs can be assigned or share functions; supported functions also depend on available I/O and software configuration. The figure in the comparison is a controller capability, not proof of compatibility with a particular engine or vehicle.

Connector and pinout

MINI connector 1, REV10+; see the linked manufacturer drawing for the connector face and its cavity positions. These positions are manufacturer-labelled ECU functions, not an assurance that a particular loom or calibration uses them. Exact wiring and connector reference.

PositionManufacturer functionNotes
A1TRIGGER
A2TRIGGER GND
A3Not assigned in source
A4Not assigned in source
B1DIN 1 (Hall onLY)
B2DIN 2 (Hall only)
B3SENSOR GND
B4SENSOR GND
C1CLT
C2IAT
C3AIN 3 (0-5V)
C4AIN 4 (0-5V)
D1GPO 8/TACHO660ohm pullup
D2TPS
D3GND Shield
D4SENSOR GND
E1GPO 3
E2+5V sensor supply(peak 0.5A, max 150mA)
E3CAN LRead important note below if you encounter issues with CAN communications!
E4CAN HRead important note below if you encounter issues with CAN communications!
F1IGN 1
F2IGN 2
F3IGN 3
F4IGN 4
G1GPO 2
G2GPO 1
G3INJ 1
G4ENGINE GND
H1INJ 2
H2INJ 3
H3INJ 4
H4+12V (ECU power supply)

Consult the full diagram for wiring, grounds, supply fuses, driver limits, connector orientation and remaining positions. Sensor grounds and power grounds have different purposes; follow the matching manual.

MaxxECU reports that approximately the first 100 MINI harnesses delivered in 2019 had CAN H and CAN L swapped in harness labelling; ECU positions remain E4 CAN H and E3 CAN L. Verify the actual loom against the manufacturer’s harness notice.

Software and further documents

Sources reviewed 17 November 2026.

Directly applicable articles