Factory control and logged pressure
Scope: These are EA888 Simos 18 examples, mainly 18.1. Exact ECU hardware, engine, transmission, software, calibration and patches determine whether a function or definition applies. Community labels are research leads: confirm the target A2L, axes, units, scaling, selectors and logs. Neither listed names nor file ranges are recommended settings.
Boost control follows an air and torque request, while compressor and turbine models and feedback participate in control and protection. Simos Wiki describes pressure upstream of the throttle (PUT), manifold pressure and electronic wastegate position in its EA888 example. Confirm the installed actuator and sensors: other hardware or a patch can change the path.
Names in a community definition
The bri3d a2l2xdf community definition list labels ip_fac_bpa_sp[0] and ip_fac_bpa_sp[1] wastegate position feedforward VVL 0/1. The SC8S5031 community cross-reference describes a boost-pressure actuator setpoint with factor inputs and an adaptive correction. Community XDF index labels can differ from the A2L entry; verify the active selector and axes, rather than assuming every file uses the same array index.
ip_put_sp is a pressure-upstream-throttle setpoint label in that community family. A particular SC8S5031 reference lists rpm and manifold pressure setpoint as its axes. ip_ad_fac_bpa_sp is described as an adaptive correction in the community adaptation reference; this is not a generic new base table to copy.
Factory pre-control and adaptation: a specific software example
In the SC8S5031 turbine-control cross-reference, ip_fac_bpa_sp[1] has factor inputs fac_1_put_ad and fac_2_put_ad. They are not generically rpm and requested boost. The same page's map label and axis label disagree about which VVL index they describe; verify the target definition and actual selector rather than assigning an index from the caption.
The related ip_fac_bpa_sp_amp_ofs is described as a correction indexed by ambient pressure and wastegate-flow setpoint. ip_ad_fac_bpa_sp is a separate adaptive correction; the adaptation reference shows factor and wastegate-flow inputs and describes saved adaptation in this example. ctr_put_ad, lv_fac_put_ad_act and lv_inh_put_ad are runtime counter/status or inhibit signals, not base calibration maps. Record adaptation and operating conditions before diagnosing a learned correction; do not reset it blindly.
Pressure setpoint stages and actuator output
The SC8S5031 pressure-setpoint reference defines ip_put_sp against engine speed and manifold-pressure setpoint prs_im_sp, with hPa output. This is a regular candidate request, not measured boost or necessarily the final target. ip_put_sp_fil_inc_2 is a filtered-pressure increment map against protection-filtered setpoint put_sp_fil_prot and ambient pressure, also outputting hPa. put_sp_rgl, put_sp_fil and put_sp_fil_prot are runtime stages, not calibration tables. Compare the relevant stage to the final target and actual pressure, with consistent absolute/gauge references.
The turbine-control reference describes ip_posn_sp_bpa_max as a maximum regular actuator-position request versus engine speed and air mass per stroke; it is not the measured actuator position or a physical stop. ip_posn_sp_bpa_rgl_conv converts the regular pressure-control factor into an actuator-position request, with additional selection possible in the documented strategy. fac_pow_put_ctl_opl and fac_pow_put_ctl_rgl are runtime open-loop and regular control values, not maps or actual actuator feedback.
For the outer pressure controller's ip_fac_pow_put_ctl_i and ip_fac_pow_put_ctl_p_d families, the application reference lists pressure-deviation put_dif_put_ctl and pressure-increment put_inc_mmv inputs in hPa. It identifies cuboids; confirm the remaining dimension and selection in the matching ASW. ip_crlc_put_dif_put_ctl is a pressure-difference filtering calibration, not a proportional or integral gain. Verify extracted captions and units before interpreting any table.
On supported MQB vehicles, COBB distinguishes Turbine Actuator Base Value, Turbine Actuator Final Value, proportional and integral terms, and raw request. These are product-specific control outputs; compare them with actual position feedback where available and verify polarity, sampling and scaling. A controller term at zero while the controller is inactive does not alone establish a fault.
Pressure controller versus actuator-position controller
The SC8S5031 boost-pressure-control reference lists fac_pow_put_ctl_i and fac_pow_put_ctl_p_d as runtime integral and combined proportional/derivative contributions, plus lv_put_ctl_act for controller activity. These are measurements, not gain tables. Their availability and naming depend on the logger and software; a zero integral contribution during a shift or fast torque intervention does not alone demonstrate a fault.
For the outer controller, the separate SC8S5031 application cross-reference lists ip_fac_pow_put_ctl_i and ip_fac_pow_put_ctl_p_d as calibration families for integral and combined proportional/derivative contributions, with ip_fac_pow_put_ctl_i_stat and ip_fac_pow_put_ctl_p_d_stat as stationary-operation counterparts. The index identifies them as cuboids and exposes pressure-deviation and pressure-increment inputs; do not assume those are the complete axes in another ASW. Their names should not be conflated with the runtime contributions above or used as a universal tuning recipe.
By contrast, the actuator-position controller reference describes ip_fac_kp_bpa_ctl_cor_neg and ip_fac_kp_bpa_ctl_cor_pos as correction maps for the actuator position controller's amplification. Their inputs concern position and position deviation in the cited definition. They are not automatically the outer boost-pressure PID gains. First establish whether the commanded actuator position is achieved before attributing pressure error to the position controller.
The SC8S5031 actuator sensor reference lists posn_bpa_raw, posn_bpa_sae and vp_bpa_bas as raw position, SAE representation and position-system voltage measurements. The position-control reference also lists posn_fil_bpa as filtered position. Compare these with the commanded position only if the ECU and logger expose them, with correct scaling and actuator polarity. Do not transfer a voltage setting from a different turbo or actuator.
Two patches, different behaviour
The VehiCAL boost patch says it changes the ip_fac_bpa pre-control axes from intake/exhaust factors to rpm and boost setpoint while retaining PID feedback. Its axes and table must be calibrated for the application.
Separately, the simos.app Easy Wastegate guide documents Wastegate Position Feedforward VVL 0 and Wastegate Position Feedforward VVL 1 maps with rpm and requested-boost axes, in a different control approach. Do not assume VehiCAL's PID description applies to Easy Wastegate or vice versa. The linked Easy Wastegate guide describes its Y axis as relative boost in hPa; verify the installed patch version, pressure reference, scaling and logger before using it.
On changed hardware, stock-model turbo-speed and compressor-temperature estimates can be misleading. Changing associated limits without an alternative means of protecting the actual hardware can remove protection; keep physical limits and measurement in view.
EcuTek RaceROM separately documents an optional simplified pre-linearisation based on engine speed and PUT setpoint, replacing its described factory turbine-model lookup for that feature. This is feature- and version-specific; do not assume the same pressure axes or control behaviour as the other patches.
Diagnose before adjusting
Compare the corresponding pressure target/actual, wastegate setpoint and measured position, rpm, valve-lift state, throttle, actuator limits, adaptations and interventions. Check for a mechanical restriction or leak and verify the sensor range. In a turbo-swap thread, copying another calibration's maps did not by itself solve the reported behaviour; the cause remained uncertain.
For MAP and upstream-throttle sensor scaling, pressure references and validation, see Simos 18 MAP and boost pressure sensors.
For compressor speed, surge, temperature and coordinated limits, see the separate Simos 18 turbocharger protection guide.
Detailed air-path guides: air charge modelling · throttle control.
Related guides: bigger turbos · wastegate and boost control · fuel-system and MPI upgrades · ethanol and flex fuel · torque model and DSG · ignition and knock · launch control · rolling anti-lag.
References reviewed 17 November 2026. Forum accounts are reported observations, not independently verified fixes.