Removed text is struck through; added text is highlighted.
What the filter is
A diesel particulate filter is a wall-flow trap in the exhaust. The brick is a honeycomb of small channels. Half of them are plugged at the inlet face and half at the outlet face, in a checkerboard. Exhaust enters an open inlet channel, has nowhere to go at the far end, and is forced through the porous wall into a neighbouring outlet channel. The gas leaves. The soot stays on the wall and in the pores.
That is the whole job of the hardware. Burning the soot back off is regeneration, and it is a control-system job described on DPF regeneration. The solid residue that will not burn is ash. The control unit’s estimate of how full the brick is, which is not the same thing as the pressure reading, is the load model.
A petrol particulate filter on a direct-injection engine is the same wall-flow idea in a hotter exhaust. This section is the diesel filter. Sensor faults, aborted cycles and the warning lamp are on particulate filter faults. Why the soot is formed in the first place is on petrol and diesel emissions.
The pages
Substrates and coatings: cordierite, silicon carbide, aluminium titanate, metal structures, and the washcoat that makes soot burn at a lower temperature.
PAT fluid and fuel-borne catalysts: the additive metered into the diesel on Peugeot, Citroën and related engines, the Eolys generations, and why they must not be mixed.
Soot and ash: what burns in a regeneration and what is left in the channels afterwards.
Load models: pressure-only, soot-only, and separate ash and soot. Some calibrations leave ash monitoring switched off.
Regeneration: passive oxidation, an active burn the control unit starts, and a workshop regeneration.
Cleaning: how ash is actually taken out of a brick, and what a bottled cleaner does not do.
What sits around the brick
The can is a steel shell with mats that hold the brick and take up expansion. Upstream there is usually an oxidation catalyst, either in its own can or coated on the front of the filter. That catalyst turns some of the nitric oxide in the exhaust into nitrogen dioxide, and it lights any fuel that a regeneration has added. Temperature sensors sit ahead of the filter and often behind it. A pressure sensor reads the drop across the brick, either as one differential sensor or as two absolute sensors subtracted in the control unit. The hoses on that sensor are part of the measurement. A hose full of water or soot reports a filter that is not the filter on the car.
Engines that use a fuel-borne catalyst have a second tank, or a pouch, and a dosing pump that puts a measured quantity of additive into the fuel when the tank is filled. That circuit is separate from AdBlue. AdBlue is injected into the exhaust for the NOx catalyst, described on selective catalytic reduction. PAT fluid goes into the diesel.
A full filter is two different problems
Soot is carbon. A completed regeneration oxidises it and the pressure drop falls. Ash is the incombustible remainder from the oil, from worn metal, and from the fuel-borne catalyst itself. It packs at the closed ends of the inlet channels, steals volume, and leaves a pressure drop that a regeneration cannot remove. A control unit that models only soot will eventually treat that leftover pressure as soot, and it will try to burn something that is not there. A control unit that models ash separately will keep regenerating for soot and will call for a clean or a new filter when the ash mass, or the pressure that remains after a good burn, reaches its limit.
Common DPF problems and checks
A DPF warning, frequent regenerations, loss of power or high exhaust restriction can have more than one cause. Record the warning, fault codes, engine and exhaust temperatures, calculated soot and ash loads and the test conditions before replacing a part. Particulate filter faults gives further diagnosis.
Common issuePossible signsChecks that help
Soot accumulation or regeneration repeatedly interruptedFilter warning, more frequent regeneration or reduced performance.Check driving and regeneration history, engine temperature, faults, injector and airflow operation, and whether the vehicle meets the manufacturer’s regeneration conditions. Excess soot can also arise from a combustion fault.
Ash or other non-combustible depositsRestriction or rising pressure drop that persists after a properly completed regeneration.Consider service history, oil specification, soot and ash estimates and measurements at the specified conditions. Regeneration oxidises soot but does not remove accumulated ash. Assess the manufacturer’s approved cleaning or replacement options. US EPA: DPF operation and maintenance.
Pressure sensor, pipes or wiring faultyImplausible pressure readings, a fault code or abnormal regeneration decisions.Inspect blocked, split or leaking hoses and take-offs, electrical supply and sensor response. Compare readings with the correct conditions and procedure: high pressure by itself does not establish that the filter is blocked. DPF differential pressure sensors; HELLA: Touareg example.
Temperature sensor or heating strategy faultRegeneration may be inhibited or interrupted on an affected system.Check the sensor and wiring, actual operating state and the specified test. See exhaust gas temperature sensors.
Damaged filter substrate, exhaust leak or high soot downstreamNoise, exhaust leak or filter-efficiency fault; low restriction is not proof of an intact filter.Inspect the exhaust and use the vehicle-specific efficiency and sensor procedures. A downstream particulate matter sensor, where fitted, monitors a different property from the pressure sensor.
Fuel-borne additive system, where fittedAn additive warning or regeneration fault can accompany low additive level or dosing and circuit faults.Identify the system and approved fluid, then check the specific fault and refill procedure; an additive refill does not clean ash from the filter. PAT fluid and fuel-borne catalysts.
Use the correct vehicle procedure before attempting regeneration. The exhaust becomes very hot; do not repeatedly force regeneration to hide a sensor, engine or filter fault. Clearing a fault code or resetting a load estimate does not clean the filter. HSE: vehicle exhaust emissions.
Open each version to inspect formatting, tables and photographs.
Revision 3: Diesel particulate filters
What the filter is
A diesel particulate filter is a wall-flow trap in the exhaust. The brick is a honeycomb of small channels. Half of them are plugged at the inlet face and half at the outlet face, in a checkerboard. Exhaust enters an open inlet channel, has nowhere to go at the far end, and is forced through the porous wall into a neighbouring outlet channel. The gas leaves. The soot stays on the wall and in the pores.
That is the whole job of the hardware. Burning the soot back off is regeneration, and it is a control-system job described on DPF regeneration. The solid residue that will not burn is ash. The control unit’s estimate of how full the brick is, which is not the same thing as the pressure reading, is the load model.
A petrol particulate filter on a direct-injection engine is the same wall-flow idea in a hotter exhaust. This section is the diesel filter. Sensor faults, aborted cycles and the warning lamp are on particulate filter faults. Why the soot is formed in the first place is on petrol and diesel emissions.
The pages
- Substrates and coatings: cordierite, silicon carbide, aluminium titanate, metal structures, and the washcoat that makes soot burn at a lower temperature.
- PAT fluid and fuel-borne catalysts: the additive metered into the diesel on Peugeot, Citroën and related engines, the Eolys generations, and why they must not be mixed.
- Soot and ash: what burns in a regeneration and what is left in the channels afterwards.
- Load models: pressure-only, soot-only, and separate ash and soot. Some calibrations leave ash monitoring switched off.
- Regeneration: passive oxidation, an active burn the control unit starts, and a workshop regeneration.
- Cleaning: how ash is actually taken out of a brick, and what a bottled cleaner does not do.
What sits around the brick
The can is a steel shell with mats that hold the brick and take up expansion. Upstream there is usually an oxidation catalyst, either in its own can or coated on the front of the filter. That catalyst turns some of the nitric oxide in the exhaust into nitrogen dioxide, and it lights any fuel that a regeneration has added. Temperature sensors sit ahead of the filter and often behind it. A pressure sensor reads the drop across the brick, either as one differential sensor or as two absolute sensors subtracted in the control unit. The hoses on that sensor are part of the measurement. A hose full of water or soot reports a filter that is not the filter on the car.
Engines that use a fuel-borne catalyst have a second tank, or a pouch, and a dosing pump that puts a measured quantity of additive into the fuel when the tank is filled. That circuit is separate from AdBlue. AdBlue is injected into the exhaust for the NOx catalyst, described on selective catalytic reduction. PAT fluid goes into the diesel.
A full filter is two different problems
Soot is carbon. A completed regeneration oxidises it and the pressure drop falls. Ash is the incombustible remainder from the oil, from worn metal, and from the fuel-borne catalyst itself. It packs at the closed ends of the inlet channels, steals volume, and leaves a pressure drop that a regeneration cannot remove. A control unit that models only soot will eventually treat that leftover pressure as soot, and it will try to burn something that is not there. A control unit that models ash separately will keep regenerating for soot and will call for a clean or a new filter when the ash mass, or the pressure that remains after a good burn, reaches its limit.
Common DPF problems and checks
A DPF warning, frequent regenerations, loss of power or high exhaust restriction can have more than one cause. Record the warning, fault codes, engine and exhaust temperatures, calculated soot and ash loads and the test conditions before replacing a part. Particulate filter faults gives further diagnosis.
| Common issue | Possible signs | Checks that help |
| Soot accumulation or regeneration repeatedly interrupted | Filter warning, more frequent regeneration or reduced performance. | Check driving and regeneration history, engine temperature, faults, injector and airflow operation, and whether the vehicle meets the manufacturer’s regeneration conditions. Excess soot can also arise from a combustion fault. |
| Ash or other non-combustible deposits | Restriction or rising pressure drop that persists after a properly completed regeneration. | Consider service history, oil specification, soot and ash estimates and measurements at the specified conditions. Regeneration oxidises soot but does not remove accumulated ash. Assess the manufacturer’s approved cleaning or replacement options. US EPA: DPF operation and maintenance. |
| Pressure sensor, pipes or wiring faulty | Implausible pressure readings, a fault code or abnormal regeneration decisions. | Inspect blocked, split or leaking hoses and take-offs, electrical supply and sensor response. Compare readings with the correct conditions and procedure: high pressure by itself does not establish that the filter is blocked. DPF differential pressure sensors; HELLA: Touareg example. |
| Temperature sensor or heating strategy fault | Regeneration may be inhibited or interrupted on an affected system. | Check the sensor and wiring, actual operating state and the specified test. See exhaust gas temperature sensors. |
| Damaged filter substrate, exhaust leak or high soot downstream | Noise, exhaust leak or filter-efficiency fault; low restriction is not proof of an intact filter. | Inspect the exhaust and use the vehicle-specific efficiency and sensor procedures. A downstream particulate matter sensor, where fitted, monitors a different property from the pressure sensor. |
| Fuel-borne additive system, where fitted | An additive warning or regeneration fault can accompany low additive level or dosing and circuit faults. | Identify the system and approved fluid, then check the specific fault and refill procedure; an additive refill does not clean ash from the filter. PAT fluid and fuel-borne catalysts. |
Use the correct vehicle procedure before attempting regeneration. The exhaust becomes very hot; do not repeatedly force regeneration to hide a sensor, engine or filter fault. Clearing a fault code or resetting a load estimate does not clean the filter. HSE: vehicle exhaust emissions.
Revision 3: Diesel particulate filters
What the filter is
A diesel particulate filter is a wall-flow trap in the exhaust. The brick is a honeycomb of small channels. Half of them are plugged at the inlet face and half at the outlet face, in a checkerboard. Exhaust enters an open inlet channel, has nowhere to go at the far end, and is forced through the porous wall into a neighbouring outlet channel. The gas leaves. The soot stays on the wall and in the pores.
That is the whole job of the hardware. Burning the soot back off is regeneration, and it is a control-system job described on DPF regeneration. The solid residue that will not burn is ash. The control unit’s estimate of how full the brick is, which is not the same thing as the pressure reading, is the load model.
A petrol particulate filter on a direct-injection engine is the same wall-flow idea in a hotter exhaust. This section is the diesel filter. Sensor faults, aborted cycles and the warning lamp are on particulate filter faults. Why the soot is formed in the first place is on petrol and diesel emissions.
The pages
- Substrates and coatings: cordierite, silicon carbide, aluminium titanate, metal structures, and the washcoat that makes soot burn at a lower temperature.
- PAT fluid and fuel-borne catalysts: the additive metered into the diesel on Peugeot, Citroën and related engines, the Eolys generations, and why they must not be mixed.
- Soot and ash: what burns in a regeneration and what is left in the channels afterwards.
- Load models: pressure-only, soot-only, and separate ash and soot. Some calibrations leave ash monitoring switched off.
- Regeneration: passive oxidation, an active burn the control unit starts, and a workshop regeneration.
- Cleaning: how ash is actually taken out of a brick, and what a bottled cleaner does not do.
What sits around the brick
The can is a steel shell with mats that hold the brick and take up expansion. Upstream there is usually an oxidation catalyst, either in its own can or coated on the front of the filter. That catalyst turns some of the nitric oxide in the exhaust into nitrogen dioxide, and it lights any fuel that a regeneration has added. Temperature sensors sit ahead of the filter and often behind it. A pressure sensor reads the drop across the brick, either as one differential sensor or as two absolute sensors subtracted in the control unit. The hoses on that sensor are part of the measurement. A hose full of water or soot reports a filter that is not the filter on the car.
Engines that use a fuel-borne catalyst have a second tank, or a pouch, and a dosing pump that puts a measured quantity of additive into the fuel when the tank is filled. That circuit is separate from AdBlue. AdBlue is injected into the exhaust for the NOx catalyst, described on selective catalytic reduction. PAT fluid goes into the diesel.
A full filter is two different problems
Soot is carbon. A completed regeneration oxidises it and the pressure drop falls. Ash is the incombustible remainder from the oil, from worn metal, and from the fuel-borne catalyst itself. It packs at the closed ends of the inlet channels, steals volume, and leaves a pressure drop that a regeneration cannot remove. A control unit that models only soot will eventually treat that leftover pressure as soot, and it will try to burn something that is not there. A control unit that models ash separately will keep regenerating for soot and will call for a clean or a new filter when the ash mass, or the pressure that remains after a good burn, reaches its limit.
Common DPF problems and checks
A DPF warning, frequent regenerations, loss of power or high exhaust restriction can have more than one cause. Record the warning, fault codes, engine and exhaust temperatures, calculated soot and ash loads and the test conditions before replacing a part. Particulate filter faults gives further diagnosis.
| Common issue | Possible signs | Checks that help |
| Soot accumulation or regeneration repeatedly interrupted | Filter warning, more frequent regeneration or reduced performance. | Check driving and regeneration history, engine temperature, faults, injector and airflow operation, and whether the vehicle meets the manufacturer’s regeneration conditions. Excess soot can also arise from a combustion fault. |
| Ash or other non-combustible deposits | Restriction or rising pressure drop that persists after a properly completed regeneration. | Consider service history, oil specification, soot and ash estimates and measurements at the specified conditions. Regeneration oxidises soot but does not remove accumulated ash. Assess the manufacturer’s approved cleaning or replacement options. US EPA: DPF operation and maintenance. |
| Pressure sensor, pipes or wiring faulty | Implausible pressure readings, a fault code or abnormal regeneration decisions. | Inspect blocked, split or leaking hoses and take-offs, electrical supply and sensor response. Compare readings with the correct conditions and procedure: high pressure by itself does not establish that the filter is blocked. DPF differential pressure sensors; HELLA: Touareg example. |
| Temperature sensor or heating strategy fault | Regeneration may be inhibited or interrupted on an affected system. | Check the sensor and wiring, actual operating state and the specified test. See exhaust gas temperature sensors. |
| Damaged filter substrate, exhaust leak or high soot downstream | Noise, exhaust leak or filter-efficiency fault; low restriction is not proof of an intact filter. | Inspect the exhaust and use the vehicle-specific efficiency and sensor procedures. A downstream particulate matter sensor, where fitted, monitors a different property from the pressure sensor. |
| Fuel-borne additive system, where fitted | An additive warning or regeneration fault can accompany low additive level or dosing and circuit faults. | Identify the system and approved fluid, then check the specific fault and refill procedure; an additive refill does not clean ash from the filter. PAT fluid and fuel-borne catalysts. |
Use the correct vehicle procedure before attempting regeneration. The exhaust becomes very hot; do not repeatedly force regeneration to hide a sensor, engine or filter fault. Clearing a fault code or resetting a load estimate does not clean the filter. HSE: vehicle exhaust emissions.