Tuning Wiki

An exhaust gas temperature sensor (EGT sensor or EGTS) measures temperature at a particular point in the exhaust so the engine or aftertreatment control system can protect components and manage emissions. Sensors may be fitted before or after a turbocharger, catalyst or particulate filter. Some SCR systems use temperature information to manage urea dosing and monitor aftertreatment. Their number, locations, electrical design and the ECU's response depend on the vehicle.

This guide covers production resistance sensors and thermocouples used by some aftermarket or motorsport systems, together with practical diagnosis. See also petrol and diesel emissions, DPF regeneration, petrol particulate filters, SCR and urea solution, and NOx sensor diagnosis.

What the measurement is used for

The ECU uses the temperature at a sensor's location along with its calibration and other information. A measured exhaust-gas temperature is not necessarily the temperature of every part of a catalyst, turbocharger, filter brick or cylinder. Some systems use models as well as measured values; check the scan-tool label and service information to tell a measured value from an estimate. HELLA: EGT sensor function and diagnosis; NTK: EGT sensors.

Position or functionHow temperature information can be usedInterpretation
Upstream of the turbochargerMonitors hot exhaust close to the engine; control strategies may protect exhaust-side components when temperatures are excessive.Gas temperature upstream differs from that downstream; neither alone establishes every component's temperature. Sensor fitment varies.
Before or after a catalystHelps assess operating conditions and protect components. Some systems adjust fuelling or other engine controls when needed.A cold catalyst may not yet convert efficiently. Compare temperatures only under the relevant test conditions; a universal inlet/outlet difference is not a catalyst-efficiency test.
Upstream or downstream of a particulate filterUsed with other sensor and model information to manage and monitor regeneration and avoid overheating on applicable systems.A temperature value does not itself measure soot mass or prove a filter is blocked. See DPF load models.
SCR aftertreatmentTemperature helps determine suitable conditions for dosing and conversion, and can support system monitoring.A sensor fault, a dosing fault and a NOx efficiency fault are different diagnostic questions; follow the actual system test.

The HELLA aftertreatment overview describes an example with several sensors; the exact sensor set and exhaust-component order on another vehicle may differ. Petrol engines can also use exhaust temperature information for protection or filter control. Do not assume every petrol particulate filter has the same sensors or regeneration procedure as a diesel DPF.

Sensor types and signals

Many production EGT sensors use a temperature-sensitive resistance element. The ECU commonly includes a reference circuit and measures a voltage influenced by that resistance, then applies its sensor-specific calibration to report temperature. The resistance curve, circuit arrangement, reference and scan-tool value are not interchangeable between part numbers. A resistance test is performed only using the vehicle or sensor maker's method and appropriate electrical isolation; never use an ohmmeter on a powered circuit. HELLA: EGT sensor construction.

  • NTC (negative temperature coefficient): resistance falls as the sensing element warms. A non-linear curve and the resistance at a given temperature depend on the sensor.
  • PTC (positive temperature coefficient): resistance rises as the element warms. The particular material and temperature-to-resistance curve depend on its design.
  • Thermocouple: some motorsport and aftermarket EGT probes use a junction of dissimilar metals and produce a small temperature-dependent voltage. The instrument or ECU must support the thermocouple type, polarity and reference-junction compensation. This is not the same measurement as a passive NTC or PTC sensor in a resistance-divider circuit. Bosch Motorsport, Thermocouple Probe TCP K, describes one Type K example.

Some sensor assemblies include signal-processing electronics rather than exposing a passive element directly. For example, PEX describes a Type N thermocouple assembly with PWM or SENT output. Use the exact sensor and controller documentation; do not apply a resistance test intended for a passive two-wire sensor to an electronic-output assembly.

NTK gives illustrative values for particular sensor families, not universal specifications. A PTC, NTC or thermocouple probe that fits a thread or connector must not be assumed electrically equivalent. No generic wire colours, ECU pins, resistance values or voltage direction apply to every vehicle. Even with the same resistance type, the voltage at the ECU can rise or fall according to the circuit and wiring; use its diagram and specified temperature table.

Sensor position and live data

Use the vehicle's system diagram to identify the sensor physically. Scan-tool labels such as bank, sensor number, upstream, pre-turbo or post-filter are only useful when their definitions for that engine are known. A vehicle may have multiple probes with similar connectors or different lengths. Confirm the part number, location, lead routing and genuine sensor-specific diagnostic description before disconnecting or replacing a part.

On a fully cooled vehicle left long enough for temperatures to settle, compare readings with the environment and relevant temperature sensors as directed by the maker. On start-up, assess response and plausibility under the documented conditions. Heat soak, aftertreatment activity, exhaust leaks, probe position, sensor response time and engine load can cause differences between sensors; a scan value may also be substituted or unavailable during a fault. A fixed extreme or minus value may be a controller's fallback or display convention, but its meaning is not universal. HELLA's Passat example illustrates a fault value for one vehicle.

An infrared thermometer reads an external surface and depends on emissivity, reflection, distance and line of sight. A metal exhaust casing can be at a different temperature from exhaust gas or the sensing tip and changes with thermal lag; an infrared reading is not a direct substitute for the sensor or a calibrated reference probe.

Regeneration and aftertreatment

A DPF traps soot. In active regeneration the engine management system raises exhaust temperature under suitable conditions so soot can oxidise; temperature feedback is one input to the strategy. Soot loading, ash loading, exhaust flow, pressure measurements and sensor health must be considered together. A failed sensor may prevent, interrupt or alter regeneration on a particular vehicle; repeated short trips or an underlying combustion problem can also contribute to filter loading. Follow the system's fault procedure rather than forcing a burn because a temperature reading looks low. DPF regeneration; HELLA aftertreatment diagnostics.

A petrol particulate filter has its own temperature, oxygen and regeneration requirements. Some filters regenerate mainly in ordinary operation; active measures vary by engine. An EGT sensor's existence or location does not prove that the vehicle uses a particular regeneration method. An SCR system uses exhaust conditions including temperature when controlling reductant dosing where fitted. Consult the system diagram and manufacturer instructions.

Symptoms and possible causes

ObservationPossible causes or effects to investigate
Stored temperature-sensor circuit or plausibility codeOpen circuit, short, damaged connector, wiring, incorrect part or sensing element fault; interpret the code and affected sensor with the vehicle documentation.
Implausible, fixed or slowly changing live valueFailed element, poor connection, harness damage, ECU substitute value, incorrect calibration or other system conditions. A scan value alone does not identify which part failed.
Regeneration warning, increased fuel use or restricted powerA temperature fault can affect control, but filter loading, pressure lines, fuel injection and other faults can produce similar symptoms. Check the entire aftertreatment system.
Actual excessive exhaust heatMixture, injection, combustion or aftertreatment faults can create excessive temperatures and damage a sensor or other components. Diagnose the reason for heat before fitting a replacement.
Damage after exhaust workIncorrect sensor position, stretched harness, crushed connector or a leak can affect operation. Check routing and the specific component replaced.

HELLA lists wiring damage, vibration, faulty electrical supply and excessive temperature among possible causes; warning lamps and loss of performance are possible symptoms, not proof of the sensor being defective. HELLA: symptoms and causes.

Workshop diagnostic sequence

  1. Identify the system: record vehicle, engine, sensor location, part number, faults, freeze-frame data, operating state and relevant bulletins. Check whether the live value is measured, calculated, unavailable or a substituted value.
  2. Inspect the installation: with components safely cool, check the probe, exhaust joints, connector and harness for leaks, heat damage, chafing, water ingress, corrosion, loose connections and strain. Identify recent exhaust or sensor work.
  3. Compare temperatures: under the manufacturer's stated cold-soak and warm-up conditions, compare relevant live values and their response. Account for the different positions and real temperature changes; do not impose a fixed difference or a universal warm-up time.
  4. Check the circuit: follow the wiring diagram and specified procedures for supply, reference, ground, continuity and signal. On a disconnected passive resistance sensor, compare resistance at a known temperature against the correct table and look for an interrupted or implausible response as directed. Do not probe or power an unknown element using a generic procedure. A thermocouple needs an appropriate measuring input and a different test.
  5. Investigate the wider fault: check related DPF pressure and load data, exhaust leaks, regeneration state, dosing and engine faults as applicable. A temperature fault code is evidence of a monitored condition, not an automatic instruction to replace the sensor.
  6. Repair and verify: use the correct position-specific part, route and secure the cable away from heat and moving components, use the specified torque and thread treatment, and restore connections. Check fault status and live data under the prescribed test or drive conditions. Perform adaptations only when the vehicle procedure requires them.

Hot exhaust parts and regeneration can cause burns or fires. Allow adequate cooling, keep combustible materials clear, use suitable exhaust extraction for running tests and follow the manufacturer's safety and regeneration instructions. Do not initiate a forced regeneration solely to diagnose a sensor; first check the fault, preconditions and workshop procedure. HSE: vehicle exhaust emissions.

Emissions testing and UK MOT

An EGT sensor reports temperature for vehicle control; it does not measure NOx, oxygen, smoke opacity or particle number. A gas analyser, smoke meter or particle counter answers a different measurement question. See emissions testing equipment and lambda sensor diagnosis.

The DVSA MOT manual, section 8 describes applicable emissions, equipment and malfunction-indicator checks. Do not assume a routine MOT includes a dedicated EGT sensor accuracy or temperature-response test. A tailpipe pass is not proof that an EGT sensor is accurate throughout the driving cycle.

Sources and related reading