A port injector delivers fuel into the intake manifold or port. On an ASNU bench the useful result is a record for each injector: whether it seals when closed, what its spray looks like, and how much fluid it delivers under stated static and pulsed conditions. The procedure below is a practical sequence, not a substitute for the instructions for the machine, injector and fuel rail in front of you. Llandow Tuning's ASNU service description gives an example of a test, service and retest workflow.
1. Identify the set and establish the test
- Record the manufacturer number, complete suffix, quantity and customer complaint. Mark each injector by its original cylinder and keep that identity on every reading. Photograph any damage before cleaning.
- Check whether it is top feed, side feed, mechanical or electronic and select the correct ASNU rail, blocks, seals and retaining hardware. This page's electrical and pulsed-flow steps apply to compatible electronic port injectors; a mechanical injector needs its own procedure.
- Identify the connector and the manufacturer's solenoid/driver requirements. A connector shape alone does not establish impedance or permissible current. Confirm the exact bench model and test mode.
- Agree the intended test fluid, pressure, duration, temperature and pulse settings. ASNU specifies FlowRite for its test circuit; its ultrasonic-bath fluid is a different product. Follow the instructions for the actual equipment. Record what is measured and what is converted.
ASNU equipment information lists top/side feed fixtures, leak checks, static and dynamic modes and, on the Classic GDI, inductance and selectable firing. ASNU's fluid information identifies FlowRite and Bio-Clean separately.
2. Inspect and check electrically
Clean loose external dirt without pushing it into the inlet. Inspect the body, connector, terminals, inlet screen, lower cap, nozzle and sealing grooves. A cracked body, damaged terminal or missing material needs investigation before applying pressure. Keep the tips protected and do not scrape the metering surface.
With power removed, use the applicable injector and bench procedure to check the solenoid circuit. Record resistance with temperature where meaningful and compare with the same part's specification. ASNU's Classic GDI also offers an inductance check; a difference can identify a suspect coil or connection, but a normal reading does not prove hydraulic sealing, opening speed or a good spray. Do not apply these solenoid checks or a direct battery feed to a piezo injector as though it were a port solenoid.
3. Mount, prime and check for leakage
Secure the injector set in the supported rail and test fixture. Connect the matching harness; check that each bench channel corresponds to the marked injector and receiving tube. Use the machine's priming procedure and set only the pressure specified for this test. Inspect the bench connections for leakage before interpreting the injectors.
In the leak test the injector is closed while the test circuit is pressurised. Observe each nozzle for new leakage during the prescribed period and record it against that injector. A wet nozzle or fluid left from a preceding run needs to be distinguished from fresh leakage. A leak at an adapter, inlet seal or hose is a fixture problem to resolve before calling the injector faulty. Never loosen a pressurised connection; follow the equipment's pressure-release procedure.
4. Observe the spray
Use the appropriate spray-viewing position and supported test mode. Run comparable pulse conditions for the same part number, observe one injector if the machine allows, and note a persistent solid jet, dribble, missing stream, uneven plume or delayed response. A twin-spray or multi-hole pattern can be intentional: compare against the correct injector design and a known-good reference, rather than assuming every injector should produce one cone. ASNU's single-injector selection helps isolate a suspicious pattern. Record the settings and photograph the display when the equipment and procedure permit.
5. Measure pulsed and, where suitable, static delivery
Use equal test conditions and the same duration or number of commanded injections. Observe pressure while the injectors are actually operating; if it changes, correct the setup according to the machine instructions and repeat the run. Record the liquid in each corresponding tube or the digital reading. Test at suitable short and longer pulses when supported: an injector that looks close to its neighbours at high delivery can still differ at idle-like short pulses.
Static flow is a continuous-open measurement when the injector, driver and test procedure allow it. It is not required or safe to assume that every GDI or mechanical injector accepts the same static test. Observe the specified time and drive limits. Do not substitute a direct battery connection for the correct test driver. Results and flow calculations explains the units and a worked example.
6. Service if appropriate, then repeat
Keep the initial record. If this injector design permits cleaning or replacement of service parts, follow the approved method and then repeat the same leak, spray and flow tests at the same recorded settings. Compare like with like and report any remaining defect. Do not describe a non-serviceable or still-leaking injector as repaired merely because its measured flow increased. See cleaning and refitting.
Sources
- Llandow Tuning: ASNU petrol injector testing and cleaning process.
- ASNU equipment technical information; ASNU test and ultrasonic fluids.
- Bosch Motorsport: injection-valve basic information — flow pressure and voltage-dependent opening delay.