Tuning Wiki

Injector catalogue › Petrol injectors › ASNU testing

Testing guides: Port injectors | GDI injectors | Results and flow calculations | Cleaning and refitting.

A bench figure is useful only with the conditions that produced it. An ASNU report should let another technician identify the injector, reproduce the test and tell a before-clean result from an after-clean result. The measurements below are examples of how to report and compare results, not acceptance limits.

What each test tells you

TestRecordWhat it cannot establish alone
ElectricalApplicable resistance/inductance, temperature and any circuit faultCorrect spray, sealing or delivery
LeakPressure, hold time, nozzle observation and external fixture conditionDelivery during commanded injection or sealing at untested pressures
SprayPattern, individual streams, pulse setting and comparison referenceExact fuel mass or in-cylinder behaviour at all operating conditions
Dynamic / pulsedVolume or mass, duration or firing count, pulse and driver settingsStatic maximum flow or behaviour at other pulse widths
Static, if applicableContinuous-open flow, fluid, pressure and measurement timeShort-pulse linearity, offset or safe operation on every driver

ASNU's Remote Control Software can save settings and results, convert measured volume to flow and display voltage-dependent offset on supported equipment. The Digital Flow Kit offers configurable targets, pressure and temperature measurement and digital reports on compatible machines. Record any software conversion and its assumptions alongside the original reading.

From observation to next check

Observation on the benchPossible explanationNext useful check
One solenoid reads open circuitCoil, terminals or test lead may be openPower down and check at the injector terminals with the correct method and specification; inspect the connector.
Fluid appears around an inlet or adapterBench seal, incorrect fixture or injector body leakDepressurise, identify the leak location and correct the fixture before interpreting nozzle leakage.
Fresh droplets form at a closed nozzleContamination or damage at the metering seat is possibleRepeat the specified leak test after ruling out residual wetting; service only as permitted and retest.
A stream is missing, a jet forms or spray is asymmetricRestriction, damage, unsuitable drive or an intentional patternCheck the test settings and expected pattern for the same part; compare with a known-good injector.
Static flows are similar but one pulsed result differsOpening behaviour, drive, pressure or short-pulse response may differRepeat under the same recorded conditions and inspect the electrical and spray results.
Every injector reads lowCommon fluid, pressure, duration, electrical setting, fixture or reference mismatch is possibleCheck the equipment and specification before condemning the set.

These are diagnostic leads, not automatic diagnoses. ASNU lists leak, flow, spray and electrical functions; Llandow Tuning records before-and-after results where the service permits.

Convert a timed tube reading

Average delivered volume rate (cc/min) = volume collected in mL × 60 ÷ time in seconds. One mL equals one cc. For example, 100 mL collected in 30 seconds is 200 cc/min for that test condition. If the injector was pulsing, 200 cc/min is the average rate over the test interval, not its continuous-open rating. Do not simply divide by duty cycle to claim static flow: opening and closing delays and short-pulse non-linearity affect the result.

If a bench reports the actual count of commanded injections for that channel, average volume per injection = collected volume ÷ injection count. For example, 97 mL over 3,000 injections is approximately 0.0323 mL, or 32.3 mm³, per commanded injection. This is an illustrative calculation; use the bench's actual count and account for its measurement resolution.

Compare a matched set

Imagine four equivalent injectors producing 100, 98, 96 and 94 mL in the same timed, pulsed test. Their mean is 97 mL. Two commonly used descriptions of spread are different:

  • Range as a percentage of the mean: (100 − 94) ÷ 97 × 100 = approximately 6.2%.
  • Largest deviation from the mean: 3 ÷ 97 × 100 = approximately 3.1%.

Both describe the same measurements. State the formula and the reference rather than writing “3.1% matched” without explanation. A target can be the set mean or an independently specified value; those answer different questions. A closely matched set can still be uniformly low, leaking or have the wrong spray. Repeat an unexpected result, check the fixture and, after safely depressurising, investigate whether the reading follows the injector or the test channel.

Before and after

Compare identical pressure, fluid, temperature, drive and duration. If a cleaned injector's volume rises but its nozzle still leaks or the spray remains abnormal, the flow improvement does not erase the fault. If it changes only at short pulses, report that separately. If the maker provides a limit for the exact part and test, use it; otherwise record the observation as unverified against a specification. There is no universal percentage in this guide that makes every petrol injector pass.

Pressure and fluid conversions

For comparable static flow of the same liquid through an injector under the assumptions in Bosch's EV injection-valve information, Q₂ = Q₁ × √(ΔP₂ ÷ ΔP₁). ΔP is the pressure difference across the injector. As an estimate, 300 cc/min at 3 bar becomes about 346 cc/min at 4 bar. This does not supply short-pulse, dead-time or spray data and should not be used to certify GDI behaviour at operating pressure.

Mass flow and volume flow also depend on the test fluid's density and temperature. For example, Bosch's document gives different conversion densities for n-heptane and gasoline; using the wrong one makes unlike figures appear comparable. Keep the measured liquid and any converted fuel value labelled. ASNU software can convert FlowRite readings using its own fuel settings; preserve the original reading too.

Suggested report fields

  • Vehicle/engine, injector manufacturer and full part number, individual ID, original cylinder and applicable index or calibration code.
  • Bench model, relevant driver and adapters, test fluid, temperature, pressure difference, method and units.
  • Leak-test duration and result; spray observations; electrical checks where applicable; pulse width, frequency, duty, firing count and/or test time.
  • Individual pre-service and post-service readings, any calculated mean/spread and formula, service parts fitted, limitations, and the part-specific acceptance source if available.

Sources