Tuning Wiki

Injector catalogue › Petrol injectors › ASNU testing

Testing guides: Port injectors | GDI injectors | Results and flow calculations | Cleaning and refitting.

Gasoline direct injection (GDI, FSI and related names) places the nozzle in the combustion chamber. The injector and its driver are not interchangeable with an ordinary port-injector circuit. ASNU's Classic GDI equipment allows spray, leakage and comparative delivery to be examined at a much lower pressure than the vehicle's high-pressure fuel system. ASNU's Classic GDI brochure and ASNU's low-pressure testing explanation describe that distinction.

Before removal and identification

Record the vehicle, engine, fault codes, affected cylinder, injector part number and index, and any individual adjustment code before removal. Misfire counts, fuel trims and pressure readings are diagnostic clues; they do not by themselves identify a failed injector. Follow the vehicle maker's instructions for depressurising both sides of the fuel system and removing injectors. High-pressure systems can retain pressure after shutdown. Use the specified puller and protect the delicate nozzle from bending or impact.

Mark the original cylinder. Determine whether the injector is solenoid or piezo, then select the matching ASNU fixture, seal adapters, lead and driver. Injector appearance, a similar plug or the word GDI is not sufficient identification. If equipment support for the exact part cannot be established, stop and obtain the correct procedure rather than trying an arbitrary drive.

Equipment and the electrical driver

The Classic GDI brochure lists sequential GDI operation, selected injector operation, peak-and-hold current control, and static and dynamic functions. It lists the Piezo Adapter Box as an option; the separate GDI/FSI Adapter Box supports compatible machines. Check actual hardware, firmware and adapter coverage before testing: a machine name alone does not establish support for every piezo or GDI part.

Use the current, voltage, pulse shape and timing specified for the injector and approved driver. Do not power a piezo injector directly from a battery or use an ordinary port-injector driver as a substitute. Follow the equipment instructions for electrical and insulation checks: ASNU provides a Megga Meter demonstration for GDI/piezo insulation. A successful electrical check does not establish delivery or sealing.

What ASNU's lower-pressure comparison can show

ASNU's Classic GDI brochure describes its bench as operating up to 10 bar, while the same document gives 75–200 bar for some vehicle systems. That is a statement about the machine and examples described in that brochure, not a setting to apply to another bench or injector. ASNU says low pressure can make certain seating and spray irregularities easier to see; it can support before/after and injector-to-injector comparison. The manufacturer's low-pressure paper explains its reasoning.

A low-pressure pass is not proof of correct operation at full vehicle rail pressure, temperature, combustion-chamber back-pressure or every pulse condition. Llandow Tuning notes that some GDI injectors can pass bench checks and still fail on the vehicle at higher pressure. If symptoms persist, use the vehicle and injector manufacturer's diagnostic procedure and an appropriate high-pressure test where specified. Do not extrapolate a low-pressure result to certify operation at rail pressure.

Carbon and damaged filter baskets

Llandow Tuning reports that, on some VAG GDI injectors it encounters, deteriorated filter baskets and carbon can complicate diagnosis. Cleaning deposits can change flow and reveal an existing internal fault; it does not by itself establish the cause or prove the injector will work at full on-car pressure. Record the original condition and any damaged or missing filter material, and follow the part-specific service decision. See Llandow's GDI testing notes and ASNU's HDEV injector service note.

Test in the appropriate ASNU fixture

  1. Clean the exterior sufficiently to prevent debris entering the machine; inspect the body, electrical connection and tip without damaging the metering surfaces.
  2. Mount each injector with its correct rail, fittings, securing hardware and electrical harness. Prime and use the supported test-fluid and pressure settings. Verify the fixture is sealed and each marked injector corresponds to its measuring channel.
  3. With the injector commanded closed, observe leakage during the prescribed test. Distinguish nozzle leakage from a wet tip left by a prior run or an external fixture leak. Record the pressure, duration and observation.
  4. In the permitted GDI drive mode, observe each spray pattern, including separate plumes and direction, under the stated pulse conditions. Compare equivalent part numbers against a known-good pattern where available. Some bench modes extend opening time to make the pattern visible; the visible shape is a diagnostic view, not a literal image of every in-cylinder event.
  5. Measure delivered volume or mass under the prescribed pulsed conditions and record the number of firings or time, fluid, pressure and driver settings. Compare like-for-like injectors; repeat after permitted servicing at the same settings. Static flow is used only when supported for that specific injector and procedure.

ASNU's Remote Control Software can record pulse width, peak and hold current, frequency/duty and measured flow on supported Classic GDI hardware. Its separate Digital Flow Kit adds digital measurement and reporting on compatible machines. Optional equipment and software capabilities are not assumed to be present on every bench.

After testing

Check the injector maker's approved cleaning and seal procedure. The Bosch Motorsport HDEV 5.2 datasheet specifically prohibits ultrasonic cleaning for that injector; it is not evidence that every other GDI injector has the same rule. Follow the correct nozzle-seal tool, sizing and replacement requirements, and enter or verify injector adjustment data if the vehicle requires it. For example, BMW's N63 training manual requires injector adjustment after replacement of its piezo injectors.

Sources