Scope: start, after-start and warm-up

Cold cranking, the transition to running, post-start fuelling and catalyst heating are related but distinct. Their activation, combustion mode, fuel split and idle request depend on ECU software, engine, transmission, fuel and hardware. The map examples below come from the community SC8S5031_C_OEM Simos 18.1 field reference; verify the exact ASW, CAL, definition, axes, scaling and branch selectors before applying them to a file. A name or data range is not a recommended value.

On its documented CHHB/CHHA EA888 examples, Volkswagen SSP 522 describes a catalyst-heating phase with direct-injection events, ignition and air-path settings chosen for warm-up. EcuTek's Simos 18.1 combustion-mode guide reports a particular development vehicle using modes 27 then 16 after a cold start before entering mode 0; another calibration need not follow that sequence. These are mode identifiers, not map names or proof that every engine has port injection.

Start fuel mass and ignition maps

The FMSP start-fuel reference describes separate operating-mode tables. These are fuel-mass quantities or corrections, not lambda targets:

  • ip_mff_st_h_1_s and ip_mff_st_h_2_s: base values for named high-pressure start modes, with engine speed n and coolant temperature tco axes and output in mg/stroke.
  • ip_mff_st_l_1, ip_mff_st_l_1_h, ip_mff_st_l_1_mpi and ip_mff_st_l_2_mpi: separate low-pressure-start or MPI-related mode definitions. Check the exact mode, injection equipment and dimensions in the target definition; a map's presence does not establish that the branch is used.
  • ip_fac_cst_fup_l is a low-pressure-start fuel correction associated with fuel pressure and start coolant temperature. ip_fac_cst_map is a correction using ambient and measured manifold pressure. These factors act within the start calculation rather than replacing injector calibration.

The IGSP start-ignition reference lists ip_iga_st_h_prs and ip_iga_st_l_prs as basic high- and low-pressure-start ignition maps, both indexed by rpm and coolant temperature. ip_iga_st_stst_h_prs[3] is a separate stop-start-related array. Basic angle is not necessarily final delivered ignition timing.

Cranking transition and adaptation context

The SC8S5031 start-fuel reference lists ip_fac_deac_mff_st_h_prs and ip_fac_deac_mff_st_l_prs as separate high- and low-pressure-start cranking fuel deactivation factors, with start cycle count cyc_st and coolant tco axes. fac_deac_mff_st is a runtime value, not a calibration map. A cycle-indexed transition is not a fixed number of seconds; validate cycle definitions, selected pressure-start state and the changeover to post-start fuel on the exact ECU.

ip_fac_cst_mff_ad is described as a start-fuel correction based on lambda adaptation. Its axis is labelled percent and refers to lambda adaptation in the axis name, but the input is NO_INPUT_QUANTITY, and copied narrative on the source page is inconsistent. Confirm the lookup and adaptation availability before attributing a start-fuel correction to a specific learned trim. For ethanol-related interpolation, default-start and alternative-fuel after-start and warm-up names, see Simos 18 ethanol and flex fuel.

Post-start and warm-up fuelling

In the cold post-start reference, ip_add_mff_cast_ini and automatic-transmission variant ip_add_mff_cast_ini_at initialise a post-start enrichment factor at the start-to-running transition. Their axes are intake-manifold air temperature tia_im and coolant tco. ip_add_mff_deac_cast is its fade factor against corrected after-start cycle count cyc_cast_cor and coolant. ip_add_mff_cast_cha is a charger-related enrichment factor indexed by engine rpm and intake-manifold pressure; _afu variants are alternative-fuel paths whose selection must be verified.

The separate warm-up correction reference lists ip_fac_mff_tco_wup, a deactivation factor with current coolant tco and start-related coolant tco_st_cur axes, and ip_fac_mff_tco_maf_int_ast_wup, another fade factor against integrated air mass and start-related coolant. Their combined role is described by that reference; neither map alone is the measured or commanded lambda. Fuel-quality and alternative-fuel branches also require matching mode and configuration.

Catalyst-heating idle and status

The EXTC heating-idle reference lists ip_n_sp_is_ch_mt, ip_n_sp_is_ch_dri[2] and ip_n_sp_is_ch_gb[2] as after-start catalyst-heating idle-speed setpoint maps. The published axes are current coolant tco and coolant at start tco_st; the transmission and drive-position branches differ. ip_n_sp_is_ch_ofs is an rpm offset, while id_n_sp_is_ch_ast_act is a time/starting-temperature activation map, not an rpm target. Confirm the applicable selector and interaction with the idle-control setpoint.

EXTC coordination identifies temperature and ambient-pressure conditions and runtime fields including t_ast_cor_ch and lv_ch_set_off. A higher post-start idle or late ignition alone does not prove the catalyst-heating phase is active. Changes to heating can alter warm-up emissions and readiness; preserve the relevant monitoring and protections.

The EXTC torque-based heating reference separately names ip_fac_tq_add_min_ch_is and ip_fac_tq_add_min_ch as minimum heating torque-reserve correction factors at idle and out of idle. Both are indexed by engine rpm n_32 and torque request tqi_req_tra; they are factors, not idle rpm targets or ignition angles.

For equipped applications, see secondary-air injection control and diagnosis for the separate pump, valve, flow model and monitoring paths.

Diagnose and validate

Capture a true temperature-soaked start, noting soak, ambient, coolant and intake temperatures, battery voltage, fuel/blend, transmission state and hardware. Compare cranking, first firing, post-start and warmed operation separately. Where the correct logger supports them, record rpm and target, fuel rail actual and target, injection mode and pulse widths, ignition, lambda target and measured lambda, trims, misfires, and catalyst-heating status. Sensor readiness and closed-loop availability vary during the first moments; do not interpret an early lambda or trim value without checking its validity.

Check leaks, fuel-pressure delivery, injector scaling, sensor plausibility and combustion faults before attributing a cold-start problem to enrichment tables. Repeat tests across representative temperatures and fuel blends; warm idle or a full-load pull does not validate cold start.

Transient fuelling guides: acceleration enrichment · deceleration fuel cut.

For the distinct automatic stop/start and interrupted-stop recovery paths, see start-stop control and restart.

For protective lambda and torque paths at high exhaust temperatures, see Simos 18 catalyst overheating protection.

Owner report: cold-start hesitation on a modified Golf R

A 2016 Golf R owner described worsening cold-start roughness and hesitation on a car with a Garrett G25-660, aftermarket intake manifold and MPI. The reported codes were P050A00 (cold-start idle-air control performance) and P2096 (post-catalyst fuel trim too lean); the owner said a smoke test found no leak and no misfires were shown on their scan tool. The owner and tuner discussed possible causes, but no confirmed resolution or exact ECU software appears in the thread. A negative smoke test and absent displayed misfires do not establish sensor, fuel, throttle or manifold health, and the two codes do not prove one cause. Record cold-soak conditions, the relevant downstream and upstream sensor data, and actuator, fuel-pressure and injection-mode states before making a change.

Related: idle control · combustion modes and fuel split · direct injection and fuel pressure · ethanol and flex fuel · ignition timing. References reviewed 17 November 2026.