Scope. The examples below come from the community SC8S5031_C_OEM Simos 18.1 cross-reference. Confirm exact ECU software, hardware, array indices, units, active selectors and model inputs before applying a definition. The source's copied descriptions can conflict. This is an explanation of protective logic, not a recommendation to change or suppress it.
How protection can intervene
The SC8S5031 lambda-based and torque-based catalyst overheating prevention references describe separate control paths. The first uses activation and controller temperatures to calculate a protective lambda request, with defined bounds and rate factors. The second describes a power/indicated-torque limitation when its conditions are met. Active request selection and whether any particular path runs depend on the target calibration and operating state. Modelled temperature is not proof of actual catalyst temperature.
High exhaust heat can follow from load, combustion conditions and time as well as a fault; a lambda correction, ignition intervention or lower torque request must be interpreted in context. An altered exhaust or turbo can change the relationship between engine operation and component temperature. Do not infer a safe universal EGT or catalyst temperature from a log or from these map names. See exhaust gas temperature modelling.
Example lambda protection definitions
The SC8S5031 EXTC reference includes:
c_temp_cop_act_thd[1]: catalyst-overheating controller activation temperature;c_temp_cop_ctl_sp[1]is its controller temperature setpoint. They have separate functions and are not necessarily physical sensor readings.c_fac_lamb_cop_dec[1]andc_fac_lamb_cop_inc[1]: controller factors for decreasing or increasing the protective lambda contribution in the documented conditions.c_lamb_cop_pasis a passive lambda value, not an ordinary full-load target.ip_lamb_cop_minandip_lamb_cop_pctlare respectively minimum and pre-control lambda maps for the overheating path. The first uses speed and ignition-efficiencyeff_iga_av; the second uses speed and predicted cylinder air mass in mg/stroke. Validate axis inputs and selection in the target.id_lamb_cor_cop_pctlis a gear-dependent pre-control correction curve in this reference. Alternative-fuel entries also exist, but the names do not establish the fuel or switching strategy of another car.temp_cop_act[0][1]andtemp_cop_ctl[0][1]are runtime activation and control temperatures;lamb_ohp[0]is a runtime overheating-prevention lambda output. These are signals, not editable maps or proof that a physical sensor is fitted.
Power intervention and diagnosis
In the torque-based reference, c_teg_min_pow_cop and c_lamb_min_pow_cop are temperature and lambda thresholds associated with activating power limitation. c_pow_cop_delta is a power-limit ramp rate in kW/s; c_pow_cop_min is the minimum indicated power during the defined reduction. lv_tqi_cop, pow_max_cop and tqi_max_ohp are runtime request/limit signals. They are not dyno-measured power or a general proof of overheating.
- Identify the actual engine, ECU and calibration, catalyst and exhaust hardware, faults, fuel and relevant sensor or model source. Capture operating conditions and how long the load was applied.
- Where available, compare requested and actual lambda, engine speed, load, ignition, relevant temperature channels and the active torque limitation. The COBB MQB monitor list describes
EGT Upstream Turboas modelled and documents a product-specific torque-limitation source bit for high exhaust temperature. Availability and meaning vary by software and tool. - Investigate fuel delivery, mixture, misfires, exhaust restrictions, temperature inputs, cooling and hardware changes with the appropriate service information before changing calibrations. A temperature intervention can be a symptom rather than a faulty limit.
- Retain the protective and diagnostic mechanisms and validate at representative duration and conditions. Disablement or an unsupported higher threshold can leave the catalyst or other exhaust components inadequately protected.
Related: exhaust gas temperature modelling · turbocharger protection · lambda control · misfire detection.
Example from a Simos 18.1 file comparison
Scope of example: A user-supplied comparison of a Simos 18.1 stock file, Stage 1 and Stage 1 pops-low, with a WinOLS CSV definition export. LTEditor identified box code 5G0906259E and software 111SC800H6G00000. The files and definitions are not publicly available, so this is a single, independently unverified file-comparison observation, not a recommended calibration. The source’s stock values matched supported byte and 16-bit entries after accounting for table transposition. Selection, runtime logic, operating conditions and checksum suitability were not independently established.
In this comparison, both c_temp_cop_act_thd[0/1] entries changed from approximately 940 to 1,100 °C. The label identifies controller activation thresholds, not necessarily physical catalyst temperature; the selected branch, other protections and actual thermal conditions remain unverified. Raising a threshold is not evidence that the component can tolerate it.