Scope and hardware
Secondary-air injection (SAI) supplies fresh air to the exhaust during selected warm-up conditions to help catalyst heating and emissions control. It is separate from intake-boost control and fuel-tank purge. Audi's SSP 920243, engine-overview table, lists secondary air on its documented North American 1.8 and 2.0 litre EA888 Gen3 examples. Fitment, routing, sensor type and pump/valve hardware vary by engine, market and software: an ECU-family name or a field in a definition does not prove that a particular car has SAI.
A Gen3 EA888 Audi repair manual identifies a secondary-air pump V101, inlet valve N112 and pressure sensor G609 on its documented applications. Verify actual component fitment and the current vehicle-specific repair information. A pump noise at cold start alone does not prove the valve opened, that flow reached the exhaust or that the monitor passed.
The calibration examples below are research leads from the community SC8S5031_C_OEM Simos 18.1 cross-reference, not a verified definition for all Simos 18 files. Match the ASW/CAL, A2L, scaling, branch selectors and physical equipment before drawing conclusions. Ranges shown in a definition are representable ranges, not target settings.
Pump and valve activation
The SAIR control-coordination reference distinguishes catalyst-heating activation from diagnostic activation:
c_tco_sa_act_min_chandc_tco_sa_act_max_chare minimum and maximum engine-temperature conditions for catalyst-heating activation;c_tco_sa_act_min_diagandc_tco_sa_act_max_diagare separate diagnosis conditions. Do not assume one pair governs every request.ip_t_sap_act_min_chandip_t_sap_act_max_chdescribe minimum and maximum pump activation time for catalyst heating in seconds against coolant temperature at starttco_st.c_t_sap_act_minandc_t_sav_act_maxare separate pump/valve duration scalars; selection and interactions require verification.c_taa_sa_sys_actis a minimum ambient-temperature condition. Other inputs and interlocks also apply. A single temperature or time parameter is not the complete control logic.
Air-flow model and lambda
The SAIR flow-model reference describes ip_saf_mdl as a secondary-air mass-flow model in kg/h, indexed by predicted cylinder air m_air_cyl_pred in mg/stroke and engine speed n in rpm. ip_saf_cor_amp corrects the model for ambient pressure amp in hPa; ip_saf_cor_vb corrects for voltage vb in volts. ip_saf_cor_tam is labelled an ambient-temperature correction, but its axis metadata identifies taa while its narrative mentions both TAM and TAA; verify the active input on the matched calibration.
saf_kgh_mdl and saf_kgh_mdl_clc are listed runtime model values, not direct proof of a physical flow measurement. A plausible estimate does not rule out a disconnected hose, blocked passage, failed pump or leaking valve.
The separate SAIR catalyst-heating reference lists ip_lamb_sawup and ip_lamb_sawup_is as a basic lambda correction for catalyst heating and an idle-specific version, respectively, with m_air_cyl_pred and n_32 axes. ip_lamb_add_sawup adds a correction against after-start time t_ast in seconds and coolant temperature tco. c_lamb_sa_ch_min and c_lamb_sa_ch_max describe combustion-lambda limits for this path. Check the whole selected calculation and actual oxygen-sensor readiness before interpreting any one value as the delivered lambda or changing the warm-up calibration.
Monitoring and diagnosis
The SAIR system-monitoring reference includes pressure-model comparisons for different test phases and blocked-tube or leak conditions. SAIR pressure-diagnosis fields include prs_sa_fil_diag_mdl_pha_1, a filtered model pressure for the measurement phase, and phase and stability flags. These are runtime signals rather than maps; compare sensor and model at the correct locations and phase, and confirm logger support and whether the vehicle actually has the required sensor.
Record the stored code and freeze-frame, readiness and whether a monitor actually ran. Note soak time, coolant and ambient temperatures and battery voltage; when supported, compare requested pump/valve states, actual electrical behaviour and measured SAI pressure against the appropriate diagnostic phase and expected model. Inspect hoses, connectors, the valve, pump and exhaust passage with the manufacturer's current procedure. An incomplete monitor is not automatically a component failure, and a passed electrical output test is not proof of sufficient air flow.
As a general diagnostic starting point, Ross-Tech's P0411 reference lists several possible causes, including pump, valve, hoses and electrical components. Code text and test procedures depend on application. Avoid changing monitor thresholds or disabling fault reporting to conceal a hardware problem.
Community example after intake work
In a 2020 GTI owner's discussion, a P0491 insufficient-flow complaint recurred following an aftermarket intake installation and subsequent addition of a secondary-air filter; tightening and realignment did not resolve the recurring code. The exact ECU software and cause were not established in the thread. It is an example of why the complete secondary-air route should be checked after intake work, not evidence that the filter or any single part caused that vehicle's fault.
Related: cold start tuning · catalyst overheating protection · lambda control · misfire detection. References reviewed 17 November 2026.