System and scope
The evaporative-emissions system stores fuel vapour in an activated-charcoal canister and meters purge flow into the engine when conditions permit. The ECU-controlled canister purge solenoid is commonly identified as N80 on the documented Volkswagen application; it is not the mechanical crankcase pressure regulator. Some EA888 Gen3 plumbing joins the canister connection at the oil-separator assembly, so trace the actual hoses and check valves rather than assuming the two systems are physically independent. Volkswagen SSP 522 and SSP 820533 describe particular EA888 Gen3 applications.
The map names below are research examples from the community SC8S5031_C_OEM Simos 18.1 EVAC cross-reference. Confirm the exact ECU, ASW, CAL, engine, hardware, valve, flow path, pressure convention, units and branch selectors. A calibration label, map range or duty command alone does not prove actual flow, vapour composition or a universal setting.
Flow requests and valve characterisation
ip_flow_cpsis the fully open purge-solenoid flow characteristic, kg/h against purge-valve pressureprs_cpsin hPa. The pressure is associated with the valve flow calculation; verify the target definition's differential and sign convention. EVAC flow setpoints.ip_flow_cps_homis labelled the MIN_PURGE flow setpoint for homogeneous stoichiometric operation; the same reference's narrative describes it as a maximum flow in that state. Confirm the calculation and active conditions;ip_flow_max_cpsis a MAX_PURGE setpoint. In this reference both use engine rpmn_32and the air-mass setpointmaf_sp_tqi_cp_itin mg/stroke, with kg/h outputs. These are different operating states, not direct N80 PWM tables.ip_ratio_fuel_max_cp_homlimits the purge fuel-flow fraction relative to total fuel flow for homogeneous stoichiometric operation, against the same rpm and air-mass inputs. It is not a lambda target.ip_ratio_fuel_vap_pred_crcv_cpis a separate crankcase-vapour-related correction; verify its selection on the target. EVAC flow reference.ip_cppwm_his the higher-resolution purge-valve characteristic for the documented frequency, output in PWM percent against corrected flowflow_cor_cpsin kg/h andprs_cpsin hPa.ip_cppwm_vb_add_1is a battery-voltage additive duty correction andip_cppwm_cor_frqa frequency-related PWM correction. They characterise a valve/control path, not a universal commanded duty. EVAC valve control.ip_flow_inc_cpandip_flow_inc_fast_cpare normal and fast purge-opening flow increments in kg/h. The stated axes aremff_sp_cpin mg/stroke and rpm; the source prose also mentions kg/h for an input, so confirm the target A2L and lookup. EVAC control.
Operating-mode limits, valve frequency and transport delay
In the SC8S5031 EVAC flow-setpoint reference, ip_flow_max_open_cps limits purge flow during RAMP_OPEN and RAMP_OPEN_FAST, in kg/h against engine speed and maf_sp_tqi_cp_it in mg/stroke. Its narrative associates the limit with retaining idle-control authority. The separately listed ip_flow_max_open_cps_2, ip_flow_max_cps_2 and ip_ratio_fuel_max_cp_hom_2 relate to the documented state_opm_eng_cp = 1 second-mode path. The extracted example shows one breakpoint per axis for these _2 maps; that does not establish the size or activation of other variants. Check the matched definition, selector and hardware before assuming a second table is active.
ip_ratio_fuel_max_cp_cor is a coolant-temperature-indexed correction to the maximum purge-fuel calculation in that same reference. Its description discusses managing valve opening during extended warm-up. This is distinct from the rpm/air-mass maximum purge-fuel ratio and is not a coolant-temperature enable switch or a universal warm-up setting.
The valve-control cross-reference describes c_cppwm_frq_1 and c_cppwm_frq_2 as output frequencies in Hz. c_n_frq_1_cps, c_n_frq_2_cps and c_n_frq_hys_cps are rpm thresholds and hysteresis associated with switching frequency; c_cppwm_frq_1_cps, c_cppwm_frq_2_cps and c_cppwm_frq_hys_cps are corresponding duty-related thresholds. Frequency switching and ip_cppwm_cor_frq depend on the configured path and valve response. Do not infer a validated frequency or flow from these field names alone.
EVAC control also lists ip_t_dly_cp for the gas-transfer delay from purge valve to lambda sensor, indexed by maf_kgh_thr_cp in kg/h and map_cp_it in hPa. The source describes its representation as measured delay divided by the 100 ms filter recurrence; it is not necessarily a value in seconds. The extraction also mentions a selector for using this map, so establish which delay path is active before interpreting a delayed lambda response.
Purge ramp behaviour and mixture feedback
The SC8S5031 EVAC cross-reference distinguishes the purge-flow ramp from the valve's PWM characteristic. ip_flow_cps_inc is an increment used during MAX_PURGE, indexed by mff_sp_cp in mg/stroke and engine speed. ip_flow_dec_cp describes a RAMP_CLOSE decrement, with mff_sp_mv_kgh_cp in kg/h on its axis and a kg/h output. The source relates the closing slope to avoiding an exhaust-lambda disturbance. Confirm the execution period and scaling before treating either increment as a rate per second.
ip_flow_fac_cp is a purge-opening ramp correction indexed by cl, the canister-load-related model value. ip_flow_fac_lam_dif_maxp_cp, ip_flow_fac_lam_dif_ro_cp and ip_flow_fac_lam_dif_rof_cp are separately labelled lambda-deviation corrections for maximum-purge, opening and fast-opening states. The extraction has conflicting narrative for the RO table, so verify the call site, active state, axes and sign on the matched software. These are research leads for transient behaviour, not universal values or a reason to suppress diagnostics.
Vapour load, lambda and injection
Canister vapour can contribute fuel as well as gas flow, so purge state and canister loading matter when interpreting lambda and trims. In the EVAC load reference, ip_cl_crlc is a canister-load filter coefficient indexed by cylinder airflow maf_cyl_cp_it in kg/h; cl_mmv is a runtime filtered load estimate. Neither is a directly measured vapour composition or a generic fuel trim.
The separate EVAC injection-correction reference describes ip_crlc_mff_buf_cp as a fuel-buffer/manifold dilution filter coefficient versus maf_cyl_cp_it and throttle-to-manifold pressure quotient pq_thr_im. mff_add_cyl_cp_cbk[0] is a calculated canister-fuel contribution, not an injector calibration or direct measured flow. The flow, concentration estimate, manifold delay and fuel compensation must be interpreted together.
Canister-load filtering during purge transitions
The SC8S5031 load-model cross-reference describes ip_cl_crlc_ini as an initial filter-coefficient curve against cl_mmv, and ip_nr_step_cl as controlling the transition toward the normal ip_cl_crlc coefficient. The extraction mentions both RAMP_OPEN and entry into MAX_PURGE for initialisation, so verify the state and selection in the matched software. These curves govern how a model responds; they are not measurements of canister vapour concentration.
ip_fac_lam_grd_mmv_maxp_cp, ip_fac_lam_grd_mmv_ro_cp and ip_fac_lam_grd_mmv_rof_cp are state-specific reduction-factor maps for MAX_PURGE, RAMP_OPEN and RAMP_OPEN_FAST. In the cited definition their inputs are fac_lam_dif_cp and fac_lam_grd_mmv, both expressed as percentages. The narrative connects lambda deviation and dynamics to canister-load filtering; it also has mismatched adjacent table captions, so confirm each lookup and selector. These are not the similarly named ip_flow_fac_lam_dif_* purge-flow corrections or lambda target tables.
The same reference lists ip_flow_min_cl_clc_cp and ip_flow_min_cl_clc_ramp_cp as flow limits for canister-load calculation, with maf_cyl_cp_it in kg/h as the axis and kg/h output. The latter is described for opening and fast-opening ramps. In logs, compare purge state, available flow request and cl_mmv with lambda and its response over time; do not infer that a transient trim change alone proves the filter maps need alteration. Map names and axes are specific to this documented example.
Functional check versus normal purge
The SC8S5031 EVAM functional-check reference lists ip_flow_sp_cps_cha_mod_diagcps and ip_flow_sp_cps_not_cha_diagcps as separate charged and non-charged diagnostic conversions from purge-valve PWM setpoint and prs_dif_amp_map_diagcps pressure difference in hPa to flow setpoint in kg/h. These are diagnostic-path conversions, not the normal purge command or proof of physical flow. The runtime state_cps_diagcps represents the valve-stimulation state, while flow_sp_cps_diagcps is its requested flow. Activation depends on conditions; an inactive or incomplete test does not prove the valve or plumbing are healthy. Confirm pressure sign, diagnostic state enumeration and logger support for the matched software.
The EVAM functional-check definition also names c_fac_lam_lim_dif_diagcps_1 and c_fac_lam_lim_dif_diagcps_2 as lambda-controller-difference diagnostic thresholds for aspiration and venturi purge lines respectively. They are diagnostic scalars, not fuel or purge-flow targets. Their presence in this definition does not prove both paths are fitted or the diagnostic is active on every vehicle; trace the actual plumbing and confirm the applicable software and diagnostic state.
Logging and diagnosis
Where available, record lv_cp_ena (purge enabled), lv_cp_act or request/state, cppwm, requested/target flow, cl_mmv, lambda target and actual, trims, rpm, air charge and manifold pressure. These runtime variables are not maps. An enabled flag is not proof the valve opened; commanded duty is not a flow or concentration measurement, and a changing trim alone does not prove a purge fault.
Idle-speed coordination: The community SC8S5031 ENSC reference describes n_sp_is_cp_req as a purge-related idle speed request in rpm and lv_n_sp_is_cp_req as its request flag. Its description relates the request to the filtered canister-load estimate cl_mmv. These are runtime signals, not calibration maps, and a request is not the final coordinated target or measured rpm. Where supported, compare them with purge state, estimated load, final idle target, actual rpm and lambda before attributing an idle change to the basic idle map. Confirm signal availability and active logic on the matched ECU.
Volkswagen bulletin V201602 / 2034072 covers N80 diagnosis on its listed 2009–2017 gasoline Volkswagen models except Routan. It lists several possible codes, including P0441; a code is a diagnostic starting point, not proof of a failed valve. Follow the applicable current service procedure for the actual vehicle, including hose, valve, electrical and leak checks.
Before changing fuel or air modelling for purge-related drivability, verify the correct plumbing, check valves and pressure sources, leaks, actuator behaviour, sensor state and active purge conditions. Preserve emissions control and fault monitoring; a purge-flow table is not a substitute for repairing a stuck or leaking component.
Diagnostic examples
Volkswagen's ODIS Service VOS-19-20 identifies a historical diagnostic-plan issue for P00FE00 on its listed 2013–2019 Golf AU vehicles: the fault concerns a restricted purge-vapour line, and the described checks include N80, the J909 tank leak-detection module and wiring. Check the current vehicle-specific plan and equipment; restriction and leak codes are different faults, and this document does not establish the ECU version of every listed Golf.
In Volkswagen's 20UF recall, a seal failure in the in-tank suction jet pump can allow liquid fuel into EVAP and leakage through the canister on affected vehicles. This pump is distinct from any intake-side vacuum jet arrangement. Check vehicle identification and campaign eligibility rather than assuming all Mk7 vehicles are affected; liquid fuel leakage needs prompt professional attention.
Two owner reports show how EVAP-related and fuel-supply symptoms can overlap; neither includes a controlled diagnosis or identified ECU software. A Stratified-tuned GTI had a repeatable brief full-throttle hesitation near 3,200 rpm, a fuel smell and a rise in logged HPFP effective pump volume from about 89 to 92% near the event; fuel delivery was suspected, but the observation alone does not establish starvation, and the hesitation was later reported to have stopped after a suction-jet-pump recall repair (initial report, later update). This does not prove the cause of other hesitations or that the vehicle fell under a particular campaign code. COBB describes its MQB HPFP effective pump volume monitor as modelled, not a direct measurement of pump flow. Check campaign eligibility and relevant fault evidence, including low- and high-side fuel-pressure target and actual, and lambda, using the applicable service procedure.
A 2015 Golf R with a warm-restart symptom was first attributed to N80 and hose replacement, then to the fuel cap, and the symptom later returned before a new fuel pump appeared to resolve it (owner report). The changing account illustrates why a short-lived improvement after one repair is not proof of an EVAP fault.
Not established
The actual cause of the owner-reported hesitation and warm-restart symptoms, and the ECU software on those vehicles, are not established.
Related: crankcase ventilation · lambda control · fuel trim · idle control · air charge. References reviewed 17 November 2026.