Applicability: Engineering identifiers below are examples from the community SC8S5031_C_OEM Simos 18.1 cross-reference unless a product or different software is named. Definitions are research leads, not universal calibration values: match the ECU hardware, ASW, A2L, indexing, units, axes, scaling, signs and actual configuration. The community extraction can contain mismatched descriptions or indices. SC8S5031 reference.

Base, reference and final angles

Base ignition is one input to the final timing calculation. The reference or best-torque angle is part of the torque and ignition-efficiency model; it is not automatically the actual commanded spark. Knock, temperature, combustion mode, torque interventions and installed patches can change the final angle. Selectors for intake flap, valve lift and cam position mean a familiar table may not be active in the operating point being investigated. See the EcuTek EA888 guide and the community A2L-to-XDF groupings.

Basic and reference calibration examples

ip_iga_bas_ivvt_vvl_port_h and ip_iga_bas_ivvt_vvl_port_l are community-listed basic ignition families; ip_iga_ref_ivvt_vvl_port_h and ip_iga_ref_ivvt_vvl_port_l are reference-angle families. Verify the selected flap, valve-lift and cam indexes. These group names do not establish that an individual cell is the final timing output. ip_iga_bas_afl_cbk_sel[0][1] and ip_iga_bas_afr_cbk_sel[0][1] are example lean/rich basic-angle maps, with engine speed and cylinder air mass axes and crank-angle output in the published instance. Their indices are not universal load or WOT selectors. Basic ignition angle calculation. ip_fac_iga_bas is an interpolation factor for the lean/rich basic-angle relationship, with lambda ratio and cylinder air mass as inputs in the example. ip_lamb_iga_afl is a lambda-related interpolation reference map and c_lamb_iga_afr a rich-reference calibration. The source extraction is inconsistent about the lambda signal feeding this path, so confirm the matching implementation before treating it as measured or commanded lambda. lamb_ratio and iga_bas_cbk_sel[0][1] are runtime measurements. Basic ignition reference. ip_iga_ref_sel[1] is a reference-angle example versus speed and cylinder air mass; ip_iga_ref_lamb is a reference-angle lambda-setpoint correction. Neither alone establishes delivered spark. Reference ignition calculation.

The reference presents the basic-angle blend as IGA_BAS = IGA_BAS_AFR + (IGA_BAS_AFL − IGA_BAS_AFR) × IP_FAC_IGA_BAS. In that documented relationship, a factor of 0 selects the rich-reference angle and 1 selects the lean-reference angle; intermediate values interpolate. The extracted lambda input narrative conflicts, and other corrections and selections follow, so the equation is not proof of the final cylinder spark or of which table is active on another ECU. SC8S5031 basic-angle calculation.

Temperature corrections

The SC8S5031 temperature-correction reference identifies ip_iga_bas_temp_n_32 against engine speed and selected intake-air temperature tia_iga_cor_sel_cbk[0]; the source does not make that signal a direct physical sensor reading, and ip_iga_bas_temp_tco_cor against speed and coolant temperature. ip_iga_bas_temp_neg_fac and ip_iga_bas_temp_pos_fac are weighting maps using speed and cylinder air mass in the example. The corresponding reference-angle maps include ip_iga_ref_temp_n_32 and ip_iga_ref_temp_tco_cor; iga_bas_temp[0] and iga_ref_temp[0] are measurements. Do not assume each correction acts directly or alone on final spark; verify sign and selection in the matching definition.

Tool-specific views and logging

For its supported MQB applications, COBB calls the normal full-load base maps Ignition Timing Port Flaps Low, and its light-load examples Ignition Timing Port Flaps High; its displayed axes are airflow per stroke and engine speed. Final Ignition Angle Correction IAT/CAT, Switch for Charge Air Source and Ignition Angle Correction Combustion mode 0-7 are COBB display names, not a guaranteed translation to one OEM map. COBB describes its CAT as modelled and IAT as measured; check the selected source on the actual configuration.

EcuTek RaceROM documents per-mode lift and no-lift ignition tables that replace a subset of OEM tables when its feature is used; OEM idle and closed-flap maps remain relevant in its described setup. RaceROM values are base setpoints, with knock and other corrections still applied. Feature and version determine the active path.

When comparing logs, use matching fuel, ethanol content, load, rpm, temperatures, gear and valve-lift/flap/combustion mode. COBB's monitor definitions distinguish Ignition Table Output, temperature and combustion-mode corrections, Ignition Timing Final and per-cylinder timing. Its COBB Spark Reduction describes custom-feature reduction, not a substitute for cylinder knock-retard channels. Timing that does not improve measured torque can increase cylinder stress without useful gain; zero observed knock correction is not proof of adequate margin. Use controlled evaluation and preserve protective controls.

Detailed valve-train guides: camshaft timing · valve lift tuning.

For coil charge time, voltage correction and replacement-coil checks, see Simos 18 ignition coil dwell control.

Related: ignition and knock overview · ignition timing · knock detection and control · tuning and log diagnosis · ethanol and flex fuel.

Eurodyne octane slider and proposed ethanol inputThe Simos Wiki custom-features notes describe one Eurodyne implementation in which custom code uses an enabled octane slider and adjustable limits to interpolate between two basic timing lookups; with the slider disabled, the author describes selection of the low table. This is a description of a particular aftermarket feature, not a universal stock Simos strategy or proof of final spark. Confirm the installed ASW and feature version and log final ignition and knock correction.The same page labels its idea of replacing the slider input with an alternative-fuel signal a proposal, and notes that it would override the existing slider and require assessment of its interface. It is not evidence that a released feature exists or that a particular ECU measures ethanol. The source’s separate table notes describe the adjustable limits differently; resolve the discrepancy for the actual software rather than assuming either explanation applies to every version.

Rendered revisions

Open each version to inspect formatting, tables and photographs.

Revision 4: Simos 18 ignition timing

Applicability: Engineering identifiers below are examples from the community SC8S5031_C_OEM Simos 18.1 cross-reference unless a product or different software is named. Definitions are research leads, not universal calibration values: match the ECU hardware, ASW, A2L, indexing, units, axes, scaling, signs and actual configuration. The community extraction can contain mismatched descriptions or indices. SC8S5031 reference.

Base, reference and final angles

Base ignition is one input to the final timing calculation. The reference or best-torque angle is part of the torque and ignition-efficiency model; it is not automatically the actual commanded spark. Knock, temperature, combustion mode, torque interventions and installed patches can change the final angle. Selectors for intake flap, valve lift and cam position mean a familiar table may not be active in the operating point being investigated. See the EcuTek EA888 guide and the community A2L-to-XDF groupings.

Basic and reference calibration examples

  • ip_iga_bas_ivvt_vvl_port_h and ip_iga_bas_ivvt_vvl_port_l are community-listed basic ignition families; ip_iga_ref_ivvt_vvl_port_h and ip_iga_ref_ivvt_vvl_port_l are reference-angle families. Verify the selected flap, valve-lift and cam indexes. These group names do not establish that an individual cell is the final timing output.
  • ip_iga_bas_afl_cbk_sel[0][1] and ip_iga_bas_afr_cbk_sel[0][1] are example lean/rich basic-angle maps, with engine speed and cylinder air mass axes and crank-angle output in the published instance. Their indices are not universal load or WOT selectors. Basic ignition angle calculation.
  • ip_fac_iga_bas is an interpolation factor for the lean/rich basic-angle relationship, with lambda ratio and cylinder air mass as inputs in the example. ip_lamb_iga_afl is a lambda-related interpolation reference map and c_lamb_iga_afr a rich-reference calibration. The source extraction is inconsistent about the lambda signal feeding this path, so confirm the matching implementation before treating it as measured or commanded lambda. lamb_ratio and iga_bas_cbk_sel[0][1] are runtime measurements. Basic ignition reference.
  • ip_iga_ref_sel[1] is a reference-angle example versus speed and cylinder air mass; ip_iga_ref_lamb is a reference-angle lambda-setpoint correction. Neither alone establishes delivered spark. Reference ignition calculation.

The reference presents the basic-angle blend as IGA_BAS = IGA_BAS_AFR + (IGA_BAS_AFL − IGA_BAS_AFR) × IP_FAC_IGA_BAS. In that documented relationship, a factor of 0 selects the rich-reference angle and 1 selects the lean-reference angle; intermediate values interpolate. The extracted lambda input narrative conflicts, and other corrections and selections follow, so the equation is not proof of the final cylinder spark or of which table is active on another ECU. SC8S5031 basic-angle calculation.

Temperature corrections

The SC8S5031 temperature-correction reference identifies ip_iga_bas_temp_n_32 against engine speed and selected intake-air temperature tia_iga_cor_sel_cbk[0]; the source does not make that signal a direct physical sensor reading, and ip_iga_bas_temp_tco_cor against speed and coolant temperature. ip_iga_bas_temp_neg_fac and ip_iga_bas_temp_pos_fac are weighting maps using speed and cylinder air mass in the example. The corresponding reference-angle maps include ip_iga_ref_temp_n_32 and ip_iga_ref_temp_tco_cor; iga_bas_temp[0] and iga_ref_temp[0] are measurements. Do not assume each correction acts directly or alone on final spark; verify sign and selection in the matching definition.

Tool-specific views and logging

For its supported MQB applications, COBB calls the normal full-load base maps Ignition Timing Port Flaps Low, and its light-load examples Ignition Timing Port Flaps High; its displayed axes are airflow per stroke and engine speed. Final Ignition Angle Correction IAT/CAT, Switch for Charge Air Source and Ignition Angle Correction Combustion mode 0-7 are COBB display names, not a guaranteed translation to one OEM map. COBB describes its CAT as modelled and IAT as measured; check the selected source on the actual configuration.

EcuTek RaceROM documents per-mode lift and no-lift ignition tables that replace a subset of OEM tables when its feature is used; OEM idle and closed-flap maps remain relevant in its described setup. RaceROM values are base setpoints, with knock and other corrections still applied. Feature and version determine the active path.

When comparing logs, use matching fuel, ethanol content, load, rpm, temperatures, gear and valve-lift/flap/combustion mode. COBB's monitor definitions distinguish Ignition Table Output, temperature and combustion-mode corrections, Ignition Timing Final and per-cylinder timing. Its COBB Spark Reduction describes custom-feature reduction, not a substitute for cylinder knock-retard channels. Timing that does not improve measured torque can increase cylinder stress without useful gain; zero observed knock correction is not proof of adequate margin. Use controlled evaluation and preserve protective controls.

Detailed valve-train guides: camshaft timing · valve lift tuning.

For coil charge time, voltage correction and replacement-coil checks, see Simos 18 ignition coil dwell control.

Related: ignition and knock overview · ignition timing · knock detection and control · tuning and log diagnosis · ethanol and flex fuel.

Revision 5: Simos 18 ignition timing

Applicability: Engineering identifiers below are examples from the community SC8S5031_C_OEM Simos 18.1 cross-reference unless a product or different software is named. Definitions are research leads, not universal calibration values: match the ECU hardware, ASW, A2L, indexing, units, axes, scaling, signs and actual configuration. The community extraction can contain mismatched descriptions or indices. SC8S5031 reference.

Base, reference and final angles

Base ignition is one input to the final timing calculation. The reference or best-torque angle is part of the torque and ignition-efficiency model; it is not automatically the actual commanded spark. Knock, temperature, combustion mode, torque interventions and installed patches can change the final angle. Selectors for intake flap, valve lift and cam position mean a familiar table may not be active in the operating point being investigated. See the EcuTek EA888 guide and the community A2L-to-XDF groupings.

Basic and reference calibration examples

  • ip_iga_bas_ivvt_vvl_port_h and ip_iga_bas_ivvt_vvl_port_l are community-listed basic ignition families; ip_iga_ref_ivvt_vvl_port_h and ip_iga_ref_ivvt_vvl_port_l are reference-angle families. Verify the selected flap, valve-lift and cam indexes. These group names do not establish that an individual cell is the final timing output.
  • ip_iga_bas_afl_cbk_sel[0][1] and ip_iga_bas_afr_cbk_sel[0][1] are example lean/rich basic-angle maps, with engine speed and cylinder air mass axes and crank-angle output in the published instance. Their indices are not universal load or WOT selectors. Basic ignition angle calculation.
  • ip_fac_iga_bas is an interpolation factor for the lean/rich basic-angle relationship, with lambda ratio and cylinder air mass as inputs in the example. ip_lamb_iga_afl is a lambda-related interpolation reference map and c_lamb_iga_afr a rich-reference calibration. The source extraction is inconsistent about the lambda signal feeding this path, so confirm the matching implementation before treating it as measured or commanded lambda. lamb_ratio and iga_bas_cbk_sel[0][1] are runtime measurements. Basic ignition reference.
  • ip_iga_ref_sel[1] is a reference-angle example versus speed and cylinder air mass; ip_iga_ref_lamb is a reference-angle lambda-setpoint correction. Neither alone establishes delivered spark. Reference ignition calculation.

The reference presents the basic-angle blend as IGA_BAS = IGA_BAS_AFR + (IGA_BAS_AFL − IGA_BAS_AFR) × IP_FAC_IGA_BAS. In that documented relationship, a factor of 0 selects the rich-reference angle and 1 selects the lean-reference angle; intermediate values interpolate. The extracted lambda input narrative conflicts, and other corrections and selections follow, so the equation is not proof of the final cylinder spark or of which table is active on another ECU. SC8S5031 basic-angle calculation.

Temperature corrections

The SC8S5031 temperature-correction reference identifies ip_iga_bas_temp_n_32 against engine speed and selected intake-air temperature tia_iga_cor_sel_cbk[0]; the source does not make that signal a direct physical sensor reading, and ip_iga_bas_temp_tco_cor against speed and coolant temperature. ip_iga_bas_temp_neg_fac and ip_iga_bas_temp_pos_fac are weighting maps using speed and cylinder air mass in the example. The corresponding reference-angle maps include ip_iga_ref_temp_n_32 and ip_iga_ref_temp_tco_cor; iga_bas_temp[0] and iga_ref_temp[0] are measurements. Do not assume each correction acts directly or alone on final spark; verify sign and selection in the matching definition.

Tool-specific views and logging

For its supported MQB applications, COBB calls the normal full-load base maps Ignition Timing Port Flaps Low, and its light-load examples Ignition Timing Port Flaps High; its displayed axes are airflow per stroke and engine speed. Final Ignition Angle Correction IAT/CAT, Switch for Charge Air Source and Ignition Angle Correction Combustion mode 0-7 are COBB display names, not a guaranteed translation to one OEM map. COBB describes its CAT as modelled and IAT as measured; check the selected source on the actual configuration.

EcuTek RaceROM documents per-mode lift and no-lift ignition tables that replace a subset of OEM tables when its feature is used; OEM idle and closed-flap maps remain relevant in its described setup. RaceROM values are base setpoints, with knock and other corrections still applied. Feature and version determine the active path.

When comparing logs, use matching fuel, ethanol content, load, rpm, temperatures, gear and valve-lift/flap/combustion mode. COBB's monitor definitions distinguish Ignition Table Output, temperature and combustion-mode corrections, Ignition Timing Final and per-cylinder timing. Its COBB Spark Reduction describes custom-feature reduction, not a substitute for cylinder knock-retard channels. Timing that does not improve measured torque can increase cylinder stress without useful gain; zero observed knock correction is not proof of adequate margin. Use controlled evaluation and preserve protective controls.

Detailed valve-train guides: camshaft timing · valve lift tuning.

For coil charge time, voltage correction and replacement-coil checks, see Simos 18 ignition coil dwell control.

Related: ignition and knock overview · ignition timing · knock detection and control · tuning and log diagnosis · ethanol and flex fuel.

Eurodyne octane slider and proposed ethanol input

The Simos Wiki custom-features notes describe one Eurodyne implementation in which custom code uses an enabled octane slider and adjustable limits to interpolate between two basic timing lookups; with the slider disabled, the author describes selection of the low table. This is a description of a particular aftermarket feature, not a universal stock Simos strategy or proof of final spark. Confirm the installed ASW and feature version and log final ignition and knock correction.

The same page labels its idea of replacing the slider input with an alternative-fuel signal a proposal, and notes that it would override the existing slider and require assessment of its interface. It is not evidence that a released feature exists or that a particular ECU measures ethanol. The source’s separate table notes describe the adjustable limits differently; resolve the discrepancy for the actual software rather than assuming either explanation applies to every version.