CP3 is a Bosch three-plunger radial common-rail high-pressure pump. Its metering unit controls fuel entering the pumping elements, while the rail, pressure sensor, pressure-control hardware and DDE work together to meet the requested pressure. Pump output depends on shaft speed, inlet conditions, pressure, temperature and wear: an advertised pump size or power rating does not determine installed fuel delivery. Bosch common-rail catalogue.

Identification: Record the complete Bosch 0 445 … number and the vehicle/VIN, engine, drive, mounting and metering valve. Similar CP3 family labels do not establish interchangeability. Verify rotation, mounting, drive coupling, inlet, return, electrical control and rail-pressure limits against the part-specific catalogue and installer. BMW identifies Bosch 0 445 010 194 as the CP3 16/3 pump for the US M57TU2 TOP, without establishing that all markets or engines have the same pump. BMW engineering information.

Design and variants

The eccentric-driven radial layout compresses diesel in three pumping elements. Depending on the exact version, a supply or gear pump may be integrated or a separate supply arrangement used. The suction-side metering unit meters fuel before compression; the common-rail system stores the compressed fuel for injection. The pump, regulator, sensor, injector and rail form a matched system: installing a different pump does not automatically change permitted rail pressure or injection quantity.

Example typeDocumented Bosch numberWhat the example establishes
CP3S3 R700 445 010 045; 0 445 010 126Bosch training lists both as BMW R70 types; application and fitment still require part-number checks.
CP3S3 R900 445 010 073Bosch training lists this BMW example as R90/30; do not assume all R90 versions have the same interfaces.
CP3S3 R950 445 010 074; 0 445 010 108BMW R95 examples in the training parts list; R95 is distinct from R90.
CP3S3 R1100 445 010 043; 0 445 010 110Volvo examples, not evidence of direct M57 fitment.

Examples from the Bosch CP3 training and parts list. Its suffixes and components vary even within one family. R70, R90 and R110 are identification designations, not a universal horsepower or pressure rating. CP3 R70 · CP3 R90.

Audi / Volkswagen R90 examples

Bosch's training list identifies Audi 0 445 010 090 and 0 445 010 125 as CR/CP3S3/R90/20-789S. A diesel specialist lists 0 445 010 125 for specified Audi A4 B7 3.0 TDI BKN and A6 C6 3.0 TDI BMK applications, among others. These are examples; verify the exact part number and vehicle, and do not assume an Audi pump directly fits an M57. Bosch training list; specialist application list; R90 guide.

Upgrades

Options include a verified larger-displacement single pump, a modified pump tested by a diesel specialist, or a second pump with a matching controller and drive. These are complete system changes: compare tested flow at relevant pressure and pump speed, inlet and return capacity, electrical metering, rail stability and mechanical fit. Injector capacity and injection duration remain separate limits. A second pump needs appropriate belt drive, brackets, high-pressure fittings, low-pressure supply and control strategy; see the Santjer M57 dual-pump example, whose fitment is limited to the stated North American 335d layout.

Diagnosis and installation

Log requested and actual rail pressure under repeatable load and look at associated fuel-metering and rail-pressure faults. Before condemning a pump, check low-pressure supply and filter, air entry, restrictions, electrical supply and metering control, injector return leakage and rail pressure-control components. A fall in rail pressure is a system symptom, not proof of a failed pump.

Common-rail fuel can remain at very high pressure after shutdown. Use the vehicle-specific depressurisation and clean-work procedures, approved high-pressure lines and specified tightening/replacement instructions. Never loosen a live high-pressure connection to find a leak or use hands to check for leaks. After a pump failure, assess contamination throughout the fuel system and follow the manufacturer's repair and cleaning plan.

See fuelling faults, common-rail supply pumps and the M57 twin-turbo guide.