Scope: Water/methanol injection (WMI) for a Simos 18 vehicle is an aftermarket system. This page describes documented controller features and tuning considerations, not a claim that the original Simos ECU automatically controls injection or detects a WMI failure. Confirm the actual ECU software, controller firmware, wiring, sensors, installation and calibration. The examples below do not establish universal OEM WMI map names, nozzle sizes, flow targets or ignition and boost values.
System and tuning relationship
A separate controller can command a pump or solenoid based on engine conditions, while one or more nozzles deliver water/methanol into the air path. AEM describes WMI as charge cooling and knock suppression in its 30-3020 failsafe instructions; results depend on the mixture, distribution, air path and operating conditions. WMI is not interchangeable with ethanol percentage in the petrol tank, and its knock benefit is not a universal pump-octane rating.
Establish a suitable base-fuel calibration and no-WMI operating envelope with the actual hardware and fuel. If a separate WMI-dependent calibration requests additional torque, boost or timing, it needs an effective, verified response to missing or incorrect delivery. A driver-selectable low-output map may be useful, but its mere existence does not make the switch automatic or guarantee that it takes effect quickly enough. Verify what the installed tune changes and how it responds to a fault.
Controller and map-switch examples
The Syvecs WMI Controller manual lists a Simos 18 CAN receive preset with signals including RPM, manifold pressure, pedal and throttle position, drive-mode selection, actual and demanded torque, and temperatures. Availability depends on controller firmware and vehicle; validate live values and units. Receipt of engine data by a WMI controller does not establish that the Simos ECU receives WMI flow or accepts a fault or torque-limit message.
Syvecs describes controller-specific WMISelect selection of base-duty maps and limp settings; WMIState, WMIFinal and WMILimp are controller state, final output and protection indicators. Its manual lists configurable low level, current, pressure and flow checks, when the relevant sensor is assigned and the check enabled. It describes configured CAN or output warnings and notes that messages must match the receiving system. These names belong to that controller, not proven Simos OEM maps. Syvecs manual, pages 20–22.
THANAS's MQB Simos 18 map-switching description lists “Water-Methanol Injection Disabled” as one example slot for a particular flex-fuel configuration. The tuner says the maps are individually calibrated. Its listing does not establish a flow-triggered automatic fallback, nor does it describe every available Simos patch.
Flow monitoring and fault response
A pump command, electrical current, tank level, line pressure and actual delivered flow answer different questions. A full tank or operating pump does not prove that each nozzle is delivering the intended mixture. A single upstream flow measurement can detect some system-level deviations but does not by itself prove equal delivery to every cylinder or the liquid's composition.
As an example, the AEM 30-3020 injection monitor compares measured flow against configurable high and low boundaries relative to injection command, and can activate alarm outputs. AEM lists possible external responses such as a warning or map change. Those outputs require compatible wiring and a receiving control strategy: the generic device instructions do not prove native Simos 18 support or automatic map switching on a particular car.
The AEM 30-3302 V2 controller manual describes a progressive pressure-based control with Start PSI and Full PSI settings, plus a Boost-Safe output for specified armed low-fluid or controller-fault conditions. These are settings and behavior of that specific product, not Simos 18 calibration names; a controller's built-in low-fluid or electrical fault detection is not automatically equivalent to a separate nozzle-flow monitor.
Verification and logging
- Document the WMI hardware, fluid and base fuel, ECU software, selected engine calibration, controller firmware, enable conditions and fault-response path. Confirm the actual units and whether pressures are absolute or relative to ambient.
- Record WMI enable state, command, available line pressure, flow, tank level and fault output alongside RPM, load, manifold pressure and target, measured and target lambda, final ignition, per-cylinder knock correction and air/coolant temperatures. A modelled charge-temperature channel is not necessarily a physical sensor at the nozzle. Sampling and channel availability vary.
- Have the installer test the intended response using the equipment manufacturer's procedure under controlled conditions: warning, signal reception, selected ECU strategy and the resulting engine limits should all be verified. Consider low fluid, loss of flow, sensor/cable faults and controller power or communication loss. A fault indication alone is not evidence that the ECU adopted a protective calibration.
- Compare repeatable logs within the confirmed no-WMI envelope and investigate leaks, clogging, delivery inconsistency or poor fuel before further calibration changes. A wideband reading alone does not prove equal distribution or adequate knock margin on all cylinders.
- Follow the exact system's instructions for fluid, components, storage and service. Methanol is toxic and flammable; prevent unintended liquid delivery or siphoning into a stopped engine. AEM's specific kit instructions require its pump test with the nozzle disconnected from the engine. Product and local road-use restrictions vary.
Related: switchable maps · bigger turbo tuning · fuel octane and knock adaptation · ethanol and flex fuel · knock detection and control.
Sources
- Syvecs WMI controller installation and calibration manual, October 2026: stated Simos 18 CAN receive preset, controller signals and configurable protection. Verify the specific installed firmware.
- AEM 30-3020 Water/Methanol Failsafe instructions: flow monitoring and configurable alarm outputs; generic product documentation.
- AEM 30-3302 V2 WMI kit instructions: generic controller, service and safety instructions, independent mirror.
- THANAS MQB Simos 18 map-switching description: tuner-specific example of map-slot purposes.