Injector catalogue › Diesel injectors › Diesel injector testing
Testing guides: On-vehicle checks | Common-rail bench testing | Equipment | Results and coding | Mechanical, unit and HEUI.
A common-rail bench test removes the injector from the vehicle, supplies controlled test fluid and pressure, drives the injector as specified, and measures its behaviour against a plan for the complete injector part number. It can test delivery at several operating points as well as return flow and sealing. A bench result describes the injector under those conditions; it does not prove the vehicle's pump, wiring, ECU or engine is fault-free.
1. Identify and prepare
Record the manufacturer's full number and suffix, original cylinder, serial number and existing correction or classification code, symptoms and previous vehicle-test data. Check for damaged bodies, nozzles, terminals or external contamination before proceeding. Protect open ports and tips with suitable clean caps. Select the test plan that matches the part and verify the bench's supported range, fixture, software version, driver and test fluid. If the number or plan is unavailable, identify the result as an investigative test rather than a pass against manufacturer specifications.
The bench uses a controlled test liquid, not an assumed automotive pump fuel. For example, Hartridge lists ISO 4113 calibration fluid for its CRi-Pro; the exact fluid, filtration, temperature and maintenance intervals come from the bench and test-plan instructions. Initial external cleaning must not damage the injector or erase evidence; do not assume internal cleaning or dismantling is authorised before the baseline.
2. Mount safely and check the setup
Trained personnel fit the specified clean clamps, high-pressure connection, return connections and electrical adapter in the bench's enclosed test area. The system must preserve any return back-pressure required by that injector. Confirm the chosen actuator and driver: a solenoid current profile is not a substitute for a piezo drive. Follow the equipment's prime, leak-check and interlock procedure; do not bypass guarding or open pressurised fittings. A suspected fluid-injection injury needs immediate emergency medical care. HSENI safety alert.
3. Run the selected test plan
Plans differ by injector and bench. Depending on the part and licensed procedure, the machine may measure the following at prescribed pressure, temperature, drive and duration:
| Test point | Purpose |
|---|---|
| Electrical / actuator | Check supported coil or piezo characteristics and drive response using the manufacturer's procedure. |
| Sealing / leakage | Assess relevant nozzle, body or internal leakage tests under the stated conditions; a return-flow value and a nozzle leak are not the same measurement. |
| Idle and part load | Measure metered delivery and return at selected lower quantities and pressures. |
| Pilot / short injection | Check a small commanded delivery and, if specified, the response needed for short injections. |
| Full load / maximum power | Measure the higher-delivery operating point and its associated return under the test plan. |
| Emissions / additional points | Assess additional selected injection conditions where the exact plan requires them. |
These labels are examples, not a mandated order or a universal list. Hartridge's Sabre CRi Expert brochure shows electrical, idle, pilot, maximum-power, emissions and static-leak steps for one example. A skipped or unsupported step must be shown as untested, not silently treated as a pass. A spray view, when the equipment supports it safely, complements measured results; a visual plume alone cannot validate the injector.
4. Separate delivery from return
Delivery is metered fluid leaving the nozzle into the test measurement system. Return is fluid leaving through the return connection. They are different paths and can have different units, limits and test conditions. Measure each according to the plan, record the pressure and actual operating point, and compare against its own limits. A correct-looking return does not prove nozzle delivery is correct, and equal outputs do not establish that all injectors are within specification.
5. Repair, retest and document
Where repair is approved for the exact design, a specialist may service it in the prescribed clean environment, use authorised parts and tools, and then repeat the full applicable plan. Where no supported repair exists or a body, actuator or other non-serviceable part is damaged, replacement may be required. In a Delphi case example, a repaired injector was retested on an authorised bench and assigned a new calibration code. This is an example, not permission to generate codes or dismantle every injector.
Keep the individual pre- and post-service printouts, failed or omitted steps, test plan and version, hardware, fluid and temperature, measured pressure, delivered and returned quantities, repair parts, and any generated code. The next page, results and coding, explains how to read them and transfer codes to the vehicle.