Injector cleaning and flow-testing machines let a workshop assess removed injectors under controlled conditions and, where appropriate, clean and retest them. Petrol port-injection benches commonly combine a test rail, regulated test-fluid supply, injector driver, graduated collection tubes and an ultrasonic bath. Specialist gasoline direct injection (GDI) and diesel common-rail injectors require compatible fixtures, drive electronics and test procedures. A machine's connector or a marketing claim of “universal” coverage is not proof that it supports a particular injector.
What a machine can test
- Leakage: with a compatible injector closed and pressurised, inspect for leakage using the specified test method and acceptance limits. Leakage may be at a nozzle or external seal; location matters.
- Static flow: flow under a specified sustained opening, pressure and test-fluid condition, where this test is approved for that injector. Do not hold an unknown injector open continuously: drive limits differ.
- Dynamic flow and balance: compare delivered volume or mass at stated pressure, pulse width, repetition rate and duration. Repeatability and a matching set do not establish that all injectors meet specification. Results at one operating point do not establish behaviour at all others.
- Spray observation: a suitable guarded, illuminated test chamber can help reveal gross asymmetry, dribbling or blocked outlets. An atmospheric, low-pressure visual pattern is not a complete reproduction of spray and atomisation in a running engine.
- Electrical condition: some machines check solenoid resistance or drive response. Resistance alone cannot prove correct opening, insulation under operating conditions or delivery; piezo injectors need their own approved test methods.
Compare results with the injector-specific test plan where available. Record injector identity and cylinder position, test fluid and temperature, differential pressure where relevant, voltage or drive profile, pulse width, rate, duration, quantity, and leakage criteria. Express measured volume in mL and time in minutes to calculate mL/min where appropriate; a pulsed delivery rate is specific to its duty cycle and must not be presented as static flow. Conversion to mass flow requires the density of the actual test fluid and documented conditions. Differences in fluid, pressure and injector dead time make results from unlike tests unsuitable for direct comparison. ASNU Digital Flow Kit; InjectorRx test process.
Cleaning methods and limitations
Ultrasonic baths use cavitation in an approved cleaning solution; some systems pulse suitable injectors during a controlled cleaning cycle. Forward flushing and, where expressly supported for the injector, reverse flushing may remove contamination. Test first, then clean only if the injector manufacturer and equipment procedure permit the fluid, temperature, immersion depth, drive signal and duration. Do not assume all injectors, piezo assemblies, filters or coatings tolerate ultrasonic cleaning or reverse flow. Replace seals, filters or caps only when the component is serviceable and the correct parts and procedure are available. ASNU warns that chemical cleaners can damage its injectors; use the instructions for the specific injector rather than a generic solvent recommendation. ASNU injector fitting instructions.
Repeat the same leakage and flow tests after service and retain before-and-after results. Cleaning cannot repair a damaged coil, cracked body, worn seat or damaged nozzle; replace or refer components that do not meet the applicable limits. Cleaning equipment attached to a vehicle can deliver cleaning fluid through an installed fuel system, but it does not individually measure injector flow or replace a bench report.
Petrol PFI, GDI and diesel: different equipment
Petrol port-fuel injectors are commonly compared on low-pressure multi-position benches. A GDI-compatible machine needs the appropriate driver, connections, seals and fixture for the specific solenoid or piezo injector. ASNU describes its Classic GDI as a comparative test at up to 10 bar: its results should not be described as a full-pressure simulation of the engine's GDI system. ASNU offers a GDI/FSI adapter box for older Classic machines; piezo support is a separate adapter consideration.
Diesel common-rail benches are specialist high-pressure systems with enclosed test chambers, controlled test oil, dedicated injector drive, return-flow measurement and injector-specific test plans. They are distinct from petrol cleaning benches and mechanical hand-operated nozzle testers. Coverage, calibration, licences and capabilities to generate correction codes depend on the machine, software, authorisation and injector family. An apparent pass on a generic test does not establish OEM approval or a valid correction code. Bosch EPS 205; Hartridge Sabre CRi Master.
Machines, models and part numbers
The following are documented examples, including older equipment. A model name identifies a machine; other numbers below are explicitly identified as accessories or variants. Specifications, mains supply, test-plan coverage and available updates differ by version and market. Historical listing alone does not prove discontinuation.
- ASNU Classic GDI: petrol injector diagnostic and servicing system with up to eight injectors, leak-down checks, flow and spray observation and ultrasonic cleaning. Its optional Digital Flow Kit adds software control, saving and reporting. The 2022 accessory catalogue identifies ASNU 631 as an upgrade kit needed for certain older machines when using specified remote-control software; 631 is an upgrade part, not a machine model.
- ASNU Junior: petrol injector testing and servicing system for up to six cylinders, with motorcycle injectors among its intended applications. Confirm fixture and driver compatibility.
- LAUNCH CNC-603A, part no. CNC-603A-1036001: six-cylinder cleaner and tester in the 2022 UK catalogue, combining ultrasonic cleaning, leak testing, flow comparison and spray observation. This catalogue describes a 220 V / 50 Hz configuration; confirm the unit's nameplate and application.
- LAUNCH CNC605+ / X-605 Plus: six-injector cleaner/tester with EFI, GDI and piezo operating modes as described in the CNC605+ manual; X-605 Plus product information. The manual limits its on-vehicle cleaning function to EFI mode. Verify the exact model revision, adapters and covered injector types.
- AUTOOL CT150: four-position petrol injector tester and cleaner with ultrasonic cleaning and flow/leak tests. A 2022 CT150 manual documents an earlier version; verify GDI and piezo compatibility for the actual unit instead of assuming it.
- AUTOOL CT400: six-position GDI-labelled cleaner/tester with an ultrasonic tank and multiple test modes. The product page contains inconsistent model wording; confirm the specific revision, supported drive profiles and injector list with the supplier.
- Bosch EPS 205: automatic diesel common-rail injector and nozzle-holder test bench. Bosch lists 0 683 803 205 for the 400 V three-phase version and 0 683 803 206 for 200 V three-phase; its equipment brochure describes pressure generation up to 1,800 bar and test-data support. The correct adapters and coverage remain injector-specific.
- Bosch EPS 708: specialist diesel common-rail injector and pump bench. The same Bosch brochure lists 0 683 708 020 as a 400 V, three-phase version with cooling and 0 683 708 021 as a 200–240 V version with cooling; other variants differ. Bosch describes test pressure up to 2,200 bar.
- Bosch DCI 200, 0 683 225 001: single-injector common-rail bench. Bosch's equipment catalogue lists separately supplied injector adapter kits and software coverage; confirm current licences and exact injector applicability.
- Hartridge Sabre CRi Master and CRi Expert: common-rail injector test benches; the Master was introduced in 2017. HJ084 is an Expert upgrade kit, not the bench model number; Hartridge specifies qualified installation and additional capabilities. Software, test plans and any credits or licences must be checked.
- OTC 7448 and 7448A: an older 7448 manual documents an on-vehicle fuel-injector cleaning canister; 7448A is a later rail-cleaning canister. These are cleaning tools, not flow-testing benches.
Practical workflow and choosing equipment
- Identify the injector by part number, system and cylinder position; consult the vehicle and injector service information before removal. Confirm the machine, test plan, driver, adapters and seals are approved for that exact injector.
- Inspect the bench, guards, hoses, filters, collection devices and test fluid. Check calibration, maintenance and environmental requirements. Document the injector's condition and run the applicable pre-clean tests.
- Clean only with a permitted process. Keep contaminants out; observe injector-specific restrictions on immersion, pulsing, reverse flushing, filter replacement and disassembly.
- Repeat the same controlled tests, compare with the specified limits, record before-and-after values and identify anything unresolved. Check replacement seal requirements, injector coding or adaptation instructions, and refit according to the vehicle procedure.
When selecting equipment, check test-fluid compatibility, measurement uncertainty and repeatability, pressure range and regulation, maximum and minimum measurable flow, electrical drive and injector coverage, adapter availability, maintenance, mains requirements and continuing software support. A quoted maximum pressure or number of tubes alone does not establish accuracy or support for every injector.
Safety
- Fuel and test fluids may be flammable or hazardous. Use only approved fluids, ventilation, protective equipment and a suitable guarded work area; control ignition sources, spills and waste according to the applicable instructions.
- High-pressure diesel test oil can penetrate skin. Never open a pressurised connection or search for leaks by hand; follow the machine's shutdown, depressurisation and enclosure procedures. Suspected injection injury requires immediate emergency medical attention.
- GDI and diesel drivers can produce hazardous voltages; some piezo systems can retain charge. Use only approved connections and the prescribed isolation and discharge procedures. Never attach a generic 12 V pulser or ordinary noid light to an unknown injector.
- Never operate with missing guards, damaged lines or unsuitable fixtures. Injector removal and refitting require the vehicle's fuel-pressure relief procedure and, where specified, new seals and special fitting tools.
Related pages
Injector testers and noid lights · Petrol injector cleaning and refitting · Fuel pressure testers · Petrol injectors · Delphi common-rail injector numbers
See also: Automotive diesel injector test benches for diesel injector testing, coding, equipment and diagnostic limitations.
See also: Automotive diesel injection pump test benches for conventional and common-rail pump testing, equipment and diagnostic limitations.