Lambda target and feedback
Lambda expresses air–fuel ratio relative to stoichiometry for the actual fuel: 1 is stoichiometric, below 1 is richer and above 1 leaner. The ECU coordinates a target from several requests and conditions; upstream sensor feedback, controller correction and learned adaptation are separate from that target. AFR displays may use an assumed stoichiometric ratio, so confirm the tool's scaling and fuel before comparing AFR numbers.
The factory-related names below are research examples from the community SC8S5031_C_OEM Simos 18.1 cross-reference, not a universal definition. Match ECU, ASW, CAL, engine, injection equipment, mode and A2L; verify selectors, axes, units and scaling before editing. Array suffixes and representable ranges do not establish the active branch or a recommended value.
Base and coordinated lambda maps
ip_lamb_bas[0]is a basic lambda setpoint indexed by engine speedn_32and predicted cylinder air massm_air_cyl_predin mg/stroke.ip_lamb_bas_hpdi[0]andip_lamb_bas_mpi[0]are separate HPDI and MPI base setpoints with the same input types in this reference. Check the active selection and hardware; a defined MPI map does not prove port injectors are fitted. LASP base setpoint.ip_lamb_fl_spand the intake-temperature-selectedip_lamb_fl_sp_tiaare full-load enrichment contributions against rpm and elapsed full-load timet_fl.c_tia_thd_lamb_fl_spandc_tia_hys_lamb_fl_spconcern temperature branch selection;ip_lamb_inc_flandip_lamb_dec_flare rate limits, not the full-load target maps. TQDR full-load enrichment.ip_lamb_sp_tqiis a torque-related lambda map against rpm and indicated torque setpointtqi_sp_mafin Nm.id_rng_lamb_sp_tqi_actandid_rng_lamb_sp_tqi_deacdefine activation/deactivation ranges, whileip_lgrd_lamb_sp_tqilimits change rate. They are different from the requested lambda itself. TQDR torque-based setpoint.ip_lamb_sp_castis a single-injection cold-after-start setpoint versus coolant at starttco_stand post-start cycle countcyc_cast;ip_lamb_sp_cast_mplhandip_lamb_sp_cast_ststare separate multiple-injection and stop-start branches. LASP coordination.ip_fac_lamb_wupis a basic warm-up lambda factor indexed by rpm and predicted air mass, andip_lamb_bas_add_ast[1]is an after-start correction against accumulated air mass and start-related coolant temperature. They are not the final target. LASP application reference.
Other temperature, catalyst and component-protection requests may influence the coordinated target. Observe the actual target and active mode; a single table edit or a base-map cell does not prove what lambda is commanded.
Eurodyne Maestro definition caution
The Simos Wiki Eurodyne table notes warn that the axes shown for the Maestro “Basic Lambda vs Airmass DI” tables were incorrectly labelled in the author’s example. The page does not provide enough detail to establish a corrected axis mapping for every software version. Check the matching definition, axis values and active operating mode before editing, and compare the resulting commanded and measured lambda in logs. The source also distinguishes its full-load lambda table from the basic table; full-load operation should not be equated simply with accelerator-pedal position.
Feedback and controller maps
The LACO fuel-mass controller reference lists ip_fac_gain_p_lam, ip_fac_gain_i_lam and ip_fac_gain_d_lam as controller gains. Their axis descriptors are time-based and their input metadata is NO_INPUT_QUANTITY; the labels alone do not establish the runtime inputs. ip_fac_lam_max_not_stat_cdn and ip_fac_lam_min_not_stat_cdn limit controller output in nonstationary conditions. These are feedback controls and limits, not lambda target maps.
Runtime examples include fac_dif_lam_in[0] (controller difference) and fac_lam_i[0] (integral share); they are measurements, not calibrations. The SC8S5031 source describes fac_dif_lam_in as a richness-form controller difference using inverted target and measured lambda with downstream trim influence; it should not be assumed to equal a logger’s simple measured-minus-target lambda. The P, I and D gain-map axis references are labelled ldpm_t_dly_soi_lsl_pos_3_laco and ldpm_t1_lsl_up_3_laco in seconds, but both input fields are NO_INPUT_QUANTITY; confirm the actual transport and sensor-response inputs before interpreting the lookup. The LACO application reference describes stop and short-stop states. A general closed-loop flag can remain set during a short stop, so check the actual controller and sensor state. The acceleration-enrichment example includes a lambda-controller stop flag; do not assume feedback operates continuously in every transient or is always off at full load.
Product-specific controls and logs
EcuTek's EA888 RaceROM guide describes its own GDI Lambda Base Target, MPI Lambda base Target and full-load controls. These are product display names, not OEM A2L identifiers; support and interaction depend on the RaceROM feature and calibration. The simos.app Main Patch has a flex-fuel Lambda offset by rpm and load, applied with its ethanol scaling when the slot enables blending. An offset is not the final target, and its semantics should not be transferred to a different patch.
COBB's MQB monitor list identifies AFR as front-sensor derived and AFR Set Point as the target for listed vehicles. Log target and measured lambda/AFR with engine speed, load, injection mode, fuel pressure, controller state, trims, ignition, knock and temperatures as available. Consider sensor readiness, exhaust transport delay, leaks and fuel-cut state; air in the exhaust during fuel cut can appear lean without describing a firing cylinder's mixture.
Under load, compare target and measurement together with fuel delivery and correction; hitting target can still require substantial correction. Preserve sensor diagnostics, feedback and temperature protection, and evaluate the actual engine and fuel rather than copying a universal target.
Related: fuel trim and adaptation · acceleration enrichment · direct injection and fuel pressure · ethanol and flex fuel. References reviewed 17 November 2026.
For sensor location, heater calibration examples and diagnostic readiness, see Simos 18 oxygen sensors and heater diagnostics.
Example from a Simos 18.1 file comparison
Scope of example: A user-supplied comparison of a Simos 18.1 stock file, Stage 1 and Stage 1 pops-low, with a WinOLS CSV definition export. LTEditor identified box code 5G0906259E and software 111SC800H6G00000. The files and definitions are not publicly available, so this is a single, independently unverified file-comparison observation, not a recommended calibration. The source’s stock values matched supported byte and 16-bit entries after accounting for table transposition. Selection, runtime logic, operating conditions and checksum suitability were not independently established.
In this comparison, selected ip_lamb_bas[0] entries changed from approximately 1.000 to 0.850, and selected ip_lamb_sp_tqi entries from approximately 0.900 to 0.870. These are base and torque-related lookup values, respectively, not proof of the final coordinated target or measured mixture. Confirm the selected mode and compare commanded and actual lambda, fuel pressure and engine conditions.