Tuning Wiki

This is a historical revision. Read the current page or return to its history.

Page organisation in this revision
Page type
Reference hub
Subject
Engine ECU
Parent
Simos
Applies to
No ECU-specific applicability
Tool groups
None
Manufacturers
None

Simos 10 is a Continental petrol engine-management family used on Volkswagen Group vehicles. Volkswagen's Self-Study Programme 443 identifies Simos 10 on the turbocharged 1.2 TSI CBZB. Programming and logging suppliers list further applications and suffixes, but their catalogues are tool-coverage statements, not complete fitment records. Identify the ECU and its exact software before choosing a definition or procedure.

Documented application and identification

VW Self-Study Programme 443 describes the CBZB, a 1,197 cm³ four-cylinder petrol engine with two valves per cylinder, direct injection and a turbocharger. The documented version is rated at 77 kW and uses Continental Simos 10; the programme does not specify a Simos 10 suffix. Audi SSP 485 also identifies Simos 10 for its CBZA A1 and CBZB A3 examples, without specifying a suffix. See also the wiki's EA111 four-cylinder engine reference.

A 2021 Alientech driver announcement lists Simos 10 coverage for selected 1.2 TSI/TFSI vehicles from Audi, SEAT, Škoda and Volkswagen. Separately, Microtronik's Simos 10.12 listing gives Volkswagen examples for its product. These listings do not establish the ECU in every vehicle with the same badge or engine size.

Some programming catalogues disagree about applications, including a separate 2.0 TFSI listing. The CBZB example is supported by VW's own documentation; that does not resolve every conflicting catalogue entry. Check the controller label and diagnostic identification, including hardware, software and calibration identifiers, rather than assigning a suffix from the model or engine code alone. The Alientech DataLogger listing names several separate Simos 10 suffixes for logging; it is not a flashing or fitment guarantee.

Air, boost and fuel on the CBZB

On the engine described in SSP 443, an electrically operated charge-pressure actuator V465 moves the turbocharger wastegate, with position feedback from G581. The ECU derives a required charge-pressure target from the torque request, and adjusts the wastegate when actual and requested pressure differ. This is not the same control arrangement as the pneumatic N75-based system described for the earlier comparison engine. These statements are specific to the CBZB system in the programme, not a claim about every Simos 10 installation.

The documented system uses charge-pressure and intake-manifold pressure sensors with temperature measurements, plus ambient pressure. VW describes the manifold pressure and temperature signals as inputs to calculating air mass downstream of the charge-air cooler. Charge-air cooling is liquid-cooled, with a separate cooling circuit. High intake temperature can cause charge pressure to be reduced for component protection. See SSP 443, air supply and engine management.

SSP 443 also describes direct injection with two injection events during catalyst heating and under specified operating conditions up to 3,000 rpm. These are normal operating strategies on that example, not evidence that injection settings can be transferred unchanged to another ECU or calibration.

See Simos 10 1.2 TSI charge pressure and wastegate diagnosis for the documented sensor locations, actuator feedback, logging and replacement-turbo considerations.

For the separate charge-cooling circuit, V50 pump, G299 and G42 temperature signals, see Simos 10 1.2 TSI charge-air cooling and temperature logs.

Calibration and diagnosis

Start with a healthy baseline: read fault codes and investigate intake leaks, cooling-system or charge-cooling problems, fuel delivery, ignition faults and wastegate actuator or position-feedback issues before changing a calibration. A torque or boost request is a target; compare it with the reported result and investigate the active cause of a mismatch rather than assuming a particular limiter is responsible.

Where supported by the identified ECU and logger, compare requested and actual charge pressure, wastegate command and position, throttle, lambda target and actual, fuel-pressure target and actual, ignition timing and knock correction, temperatures and torque or load intervention. Confirm whether pressure is absolute or relative, whether a value is measured or calculated, and the channel's units and sampling rate. Check map axes, scaling and function against a definition for the exact software; Simos 18 addresses and control assumptions must not be copied across.

The rehosted Dimsport Simos 10.x tuning example lists abbreviated map groups and numerical changes for selected 1.2 TSI applications. It is a third-party upload, and the examples have not been validated here against a specific ECU software and hardware setup. Treat the abbreviations and suggested increases as leads for investigation, not as identified maps or universal safe settings. The Alientech driver announcement discusses Simos 10 and 18 together, so its shared list of map features does not by itself establish that each feature exists on every Simos 10 file.

Reading, writing and recovery

Diagnostic logging, a virtual read, a physical read, calibration editing and writing are different capabilities. Microtronik describes particular OBD operations in its own Simos 10.12 product listing; that does not prove another suffix or tool has the same coverage. Match the supplier's current protocol to the exact ECU and software, confirm checksum handling, supply and recovery arrangements, and keep the original read in the format the selected tool can restore.

Sources