MoTeC L180 (MoTeC part #18047) is an enclosed motorsport data logger without an integrated driver display. The information here is specific to the cited part; check the label, hardware revision, options and vehicle protocol before connection.

Specifications and options
- Enclosed logger without an integrated display; 250 MB internal recording and rates up to 1,000 samples per second.
- The manufacturer describes USB logging as an upgrade that increases internal memory to 500 MB; verify enabled options on the specific #18047 unit.
- Four configurable CAN buses, RS232, ten analogue voltage inputs and four temperature inputs as standard, with more via the 44 I/O upgrade. Power supply is specified as 6–32 V DC.
Connector and pinout
79-way (mating connector #68086): the table below follows the manufacturer’s pinout for part #18047. Check cavity numbering and the manufacturer's connector view; the functional map is not a physical connector-face drawing. Blank cells retain the source's unspecified function; do not assign them by assumption. Inputs marked as optional need the appropriate enabled upgrade.
| Pin | Name | Function |
|---|---|---|
| 1 | AV15 | Analogue Voltage Input 15 (with 44 I/O upgrade) |
| 2 | AV16 | Analogue Voltage Input 16 (with 44 I/O upgrade) |
| 3 | AV17 | Analogue Voltage Input 17 (with 44 I/O upgrade) |
| 4 | AV18 | Analogue Voltage Input 18 (with 44 I/O upgrade) |
| 5 | AV19 | Analogue Voltage Input 19 (with 44 I/O upgrade) |
| 6 | 0V | Sensor 0 V |
| 7 | BAT- | Battery Negative |
| 8 | BAT+ | Battery Positive |
| 9 | AUX1 | Auxiliary Output 1 |
| 10 | AUX2 | Auxiliary Output 2 |
| 11 | AUX3 | Auxiliary Output 3 |
| 12 | AUX4 | Auxiliary Output 4 |
| 13 | AUX5 | Auxiliary Output 5 |
| 14 | AUX6 | Auxiliary Output 6 |
| 15 | RS232-2 TX | RS232-2 Transmit Output |
| 16 | RS232-2 RX | RS232-2 Receive Input |
| 17 | 0V | Sensor 0 V |
| 18 | 5V | Sensor 5 V |
| 19 | AV7 | Analogue Voltage Input 7 |
| 20 | AV8 | Analogue Voltage Input 8 |
| 21 | AV9 | Analogue Voltage Input 9 |
| 22 | AV10 | Analogue Voltage Input 10 |
| 23 | AV11 | Analogue Voltage Input 11 (with 44 I/O upgrade) |
| 24 | AV12 | Analogue Voltage Input 12 (with 44 I/O upgrade) |
| 25 | AV13 | Analogue Voltage Input 13 (with 44 I/O upgrade) |
| 26 | AV14 | Analogue Voltage Input 14 (with 44 I/O upgrade) |
| 27 | 0V | Sensor 0 V |
| 28 | 5V | Sensor 5 V |
| 29 | Reserved | |
| 30 | Reserved | |
| 31 | Reserved | |
| 32 | Reserved | |
| 33 | 0V | Sensor 0 V |
| 34 | AT1 | Analogue Temp Input 1 |
| 35 | AT2 | Analogue Temp Input 2 |
| 36 | AT3 | Analogue Temp Input 3 |
| 37 | AT4 | Analogue Temp Input 4 |
| 38 | AT5 | Analogue Temp Input 5 (with 44 I/O upgrade) |
| 39 | AT6 | Analogue Temp Input 6 (with 44 I/O upgrade) |
| 40 | 0V | Sensor 0 V |
| 41 | AT7 | Analogue Temp Input 7 (with 44 I/O upgrade) |
| 42 | AT8 | Analogue Temp Input 8 (with 44 I/O upgrade) |
| 43 | 0V | Sensor 0 V |
| 44 | 5V | Sensor 5 V |
| 45 | AV1 | Analogue Voltage Input 1 |
| 46 | AV2 | Analogue Voltage Input 2 |
| 47 | AV3 | Analogue Voltage Input 3 |
| 48 | AV4 | Analogue Voltage Input 4 |
| 49 | AV5 | Analogue Voltage Input 5 |
| 50 | AV6 | Analogue Voltage Input 6 |
| 51 | 0V | Sensor 0 V |
| 52 | DIG1 | Digital Input 1 |
| 53 | DIG2 | Digital Input 2 |
| 54 | DIG3 | Digital Input 3 |
| 55 | DIG4 | Digital Input 4 |
| 56 | 0V | Sensor 0 V |
| 57 | SW1 | Switch Input 1 |
| 58 | SW2 | Switch Input 2 |
| 59 | CAN4L | CAN 4 Low |
| 60 | CAN4H | CAN 4 High |
| 61 | 0V | Sensor 0 V |
| 62 | 8V | Sensor 8 V |
| 63 | SPD1 | Speed Input 1 |
| 64 | SPD2 | Speed Input 2 |
| 65 | SPD3 | Speed Input 3 |
| 66 | SPD4 | Speed Input 4 |
| 67 | E-TX+ | Ethernet Transmit + |
| 68 | E-TX- | Ethernet Transmit - |
| 69 | AV20 | Analogue Voltage Input 20 (with 44 I/O upgrade) |
| 70 | RS232-1 TX | RS232 Transmit Output |
| 71 | CAN3L | CAN 3 Low |
| 72 | CAN3H | CAN 3 High |
| 73 | CAN1L | CAN 1 Low |
| 74 | CAN1H | CAN 1 High |
| 75 | CAN2L | CAN 2 Low / RS232 Ground Input |
| 76 | CAN2H | CAN 2 High / RS232 Receive Input |
| 77 | E-RX+ | Ethernet Receive + |
| 78 | E-RX- | Ethernet Receive - |
| 79 | RS232-1 RX | RS232 Receive Input |
Wiring and configuration
Use the correct connector, power and sensor return for this unit. Match CAN high and low to a compatible, correctly configured network and check existing termination. ECU channels, sensors and lap timing depend on the specific hardware, protocol, configuration and licensed options. Use manufacturer instructions for wire gauge, supply protection and continuity checks; do not connect vehicle battery voltage to a sensor reference output.
MoTeC i2 supports reviewing recorded data; Pro analysis and T2 telemetry require the applicable upgrades. A telemetry licence alone does not provide a radio or cellular connection. See the MoTeC manufacturer guide for family comparisons and references.
Data analysis software

The L180 records data for later analysis; the exact memory, logging and Pro Analysis options depend on the unit and licence. MoTeC i2 reviews recorded channels in graphs and reports; i2 Pro features depend on the device upgrade or applicable software licence. See the manufacturer model and analysis comparison and i2 software and licence information.
Retrieve a recording with the compatible MoTeC device manager, then open it in i2 to compare channels and laps when suitable position data has been recorded. Download MoTeC software from the official downloads library; see the MoTeC manufacturer guide for the Standard and Pro options.