Tuning Wiki
Browse MoTeC

MoTeC L180 (MoTeC part #18047) is an enclosed motorsport data logger without an integrated driver display. The information here is specific to the cited part; check the label, hardware revision, options and vehicle protocol before connection.

MoTeC L180 product photograph
Representative MoTeC L180 family unit; the pictured label reads 18040-09001, while this article describes part #18047. Image: MoTeC, reproduced with permission. Manufacturer product page and specifications.

Specifications and options

  • Enclosed logger without an integrated display; 250 MB internal recording and rates up to 1,000 samples per second.
  • The manufacturer describes USB logging as an upgrade that increases internal memory to 500 MB; verify enabled options on the specific #18047 unit.
  • Four configurable CAN buses, RS232, ten analogue voltage inputs and four temperature inputs as standard, with more via the 44 I/O upgrade. Power supply is specified as 6–32 V DC.

Connector and pinout

79-way (mating connector #68086): the table below follows the manufacturer’s pinout for part #18047. Check cavity numbering and the manufacturer's connector view; the functional map is not a physical connector-face drawing. Blank cells retain the source's unspecified function; do not assign them by assumption. Inputs marked as optional need the appropriate enabled upgrade.

PinNameFunction
1AV15Analogue Voltage Input 15 (with 44 I/O upgrade)
2AV16Analogue Voltage Input 16 (with 44 I/O upgrade)
3AV17Analogue Voltage Input 17 (with 44 I/O upgrade)
4AV18Analogue Voltage Input 18 (with 44 I/O upgrade)
5AV19Analogue Voltage Input 19 (with 44 I/O upgrade)
60VSensor 0 V
7BAT-Battery Negative
8BAT+Battery Positive
9AUX1Auxiliary Output 1
10AUX2Auxiliary Output 2
11AUX3Auxiliary Output 3
12AUX4Auxiliary Output 4
13AUX5Auxiliary Output 5
14AUX6Auxiliary Output 6
15RS232-2 TXRS232-2 Transmit Output
16RS232-2 RXRS232-2 Receive Input
170VSensor 0 V
185VSensor 5 V
19AV7Analogue Voltage Input 7
20AV8Analogue Voltage Input 8
21AV9Analogue Voltage Input 9
22AV10Analogue Voltage Input 10
23AV11Analogue Voltage Input 11 (with 44 I/O upgrade)
24AV12Analogue Voltage Input 12 (with 44 I/O upgrade)
25AV13Analogue Voltage Input 13 (with 44 I/O upgrade)
26AV14Analogue Voltage Input 14 (with 44 I/O upgrade)
270VSensor 0 V
285VSensor 5 V
29Reserved
30Reserved
31Reserved
32Reserved
330VSensor 0 V
34AT1Analogue Temp Input 1
35AT2Analogue Temp Input 2
36AT3Analogue Temp Input 3
37AT4Analogue Temp Input 4
38AT5Analogue Temp Input 5 (with 44 I/O upgrade)
39AT6Analogue Temp Input 6 (with 44 I/O upgrade)
400VSensor 0 V
41AT7Analogue Temp Input 7 (with 44 I/O upgrade)
42AT8Analogue Temp Input 8 (with 44 I/O upgrade)
430VSensor 0 V
445VSensor 5 V
45AV1Analogue Voltage Input 1
46AV2Analogue Voltage Input 2
47AV3Analogue Voltage Input 3
48AV4Analogue Voltage Input 4
49AV5Analogue Voltage Input 5
50AV6Analogue Voltage Input 6
510VSensor 0 V
52DIG1Digital Input 1
53DIG2Digital Input 2
54DIG3Digital Input 3
55DIG4Digital Input 4
560VSensor 0 V
57SW1Switch Input 1
58SW2Switch Input 2
59CAN4LCAN 4 Low
60CAN4HCAN 4 High
610VSensor 0 V
628VSensor 8 V
63SPD1Speed Input 1
64SPD2Speed Input 2
65SPD3Speed Input 3
66SPD4Speed Input 4
67E-TX+Ethernet Transmit +
68E-TX-Ethernet Transmit -
69AV20Analogue Voltage Input 20 (with 44 I/O upgrade)
70RS232-1 TXRS232 Transmit Output
71CAN3LCAN 3 Low
72CAN3HCAN 3 High
73CAN1LCAN 1 Low
74CAN1HCAN 1 High
75CAN2LCAN 2 Low / RS232 Ground Input
76CAN2HCAN 2 High / RS232 Receive Input
77E-RX+Ethernet Receive +
78E-RX-Ethernet Receive -
79RS232-1 RXRS232 Receive Input

Wiring and configuration

MoTeC L180 simplified power and CAN wiring
Power and CAN example, functional schematic rather than connector geometry. Original Tuning Wiki illustration based on the MoTeC product pinout; verify the actual harness and matching ECU.

Use the correct connector, power and sensor return for this unit. Match CAN high and low to a compatible, correctly configured network and check existing termination. ECU channels, sensors and lap timing depend on the specific hardware, protocol, configuration and licensed options. Use manufacturer instructions for wire gauge, supply protection and continuity checks; do not connect vehicle battery voltage to a sensor reference output.

MoTeC i2 supports reviewing recorded data; Pro analysis and T2 telemetry require the applicable upgrades. A telemetry licence alone does not provide a radio or cellular connection. See the MoTeC manufacturer guide for family comparisons and references.

Data analysis software

MoTeC i2 data analysis with channel traces and gauges
MoTeC i2 data analysis showing channel traces and gauges. Image: MoTeC, reproduced with permission; manufacturer image.

The L180 records data for later analysis; the exact memory, logging and Pro Analysis options depend on the unit and licence. MoTeC i2 reviews recorded channels in graphs and reports; i2 Pro features depend on the device upgrade or applicable software licence. See the manufacturer model and analysis comparison and i2 software and licence information.

Retrieve a recording with the compatible MoTeC device manager, then open it in i2 to compare channels and laps when suitable position data has been recorded. Download MoTeC software from the official downloads library; see the MoTeC manufacturer guide for the Standard and Pro options.