MoTeC L180 (MoTeC part #18047) is an enclosed motorsport data logger without an integrated driver display. The information here is specific to the cited part; check the label, hardware revision, options and vehicle protocol before connection.
Representative MoTeC L180 family unit; the pictured label reads 18040-09001, while this article describes part #18047. Image: MoTeC, reproduced with permission. Manufacturer product page and specifications.
Specifications and options
Enclosed logger without an integrated display; 250 MB internal recording and rates up to 1,000 samples per second.The manufacturer describes USB logging as an upgrade that increases internal memory to 500 MB; verify enabled options on the specific #18047 unit.Four configurable CAN buses, RS232, ten analogue voltage inputs and four temperature inputs as standard, with more via the 44 I/O upgrade. Power supply is specified as 6–32 V DC.
Connector and pinout
79-way (mating connector #68086): the table below follows the manufacturer’s pinout for part #18047. Check cavity numbering and the manufacturer's connector view; the functional map is not a physical connector-face drawing. Blank cells retain the source's unspecified function; do not assign them by assumption. Inputs marked as optional need the appropriate enabled upgrade.
Power and CAN example, functional schematic rather than connector geometry. Original Tuning Wiki illustration based on the MoTeC product pinout; verify the actual harness and matching ECU.
Use the correct connector, power and sensor return for this unit. Match CAN high and low to a compatible, correctly configured network and check existing termination. ECU channels, sensors and lap timing depend on the specific hardware, protocol, configuration and licensed options. Use manufacturer instructions for wire gauge, supply protection and continuity checks; do not connect vehicle battery voltage to a sensor reference output.
MoTeC i2 supports reviewing recorded data; Pro analysis and T2 telemetry require the applicable upgrades. A telemetry licence alone does not provide a radio or cellular connection. See the MoTeC manufacturer guide for family comparisons and references.
Data analysis softwareMoTeC i2 data analysis showing channel traces and gauges. Image: MoTeC, reproduced with permission; manufacturer image.The L180 records data for later analysis; the exact memory, logging and Pro Analysis options depend on the unit and licence. MoTeC i2 reviews recorded channels in graphs and reports; i2 Pro features depend on the device upgrade or applicable software licence. See the manufacturer model and analysis comparison and i2 software and licence information.Retrieve a recording with the compatible MoTeC device manager, then open it in i2 to compare channels and laps when suitable position data has been recorded. Download MoTeC software from the official downloads library; see the MoTeC manufacturer guide for the Standard and Pro options.
Rendered revisions
Open each version to inspect formatting, tables and photographs.
Revision 2: MoTeC L180
MoTeC L180 (MoTeC part #18047) is an enclosed motorsport data logger without an integrated driver display. The information here is specific to the cited part; check the label, hardware revision, options and vehicle protocol before connection.
Representative MoTeC L180 family unit; the pictured label reads 18040-09001, while this article describes part #18047. Image: MoTeC, reproduced with permission. Manufacturer product page and specifications.
Specifications and options
Enclosed logger without an integrated display; 250 MB internal recording and rates up to 1,000 samples per second.
The manufacturer describes USB logging as an upgrade that increases internal memory to 500 MB; verify enabled options on the specific #18047 unit.
Four configurable CAN buses, RS232, ten analogue voltage inputs and four temperature inputs as standard, with more via the 44 I/O upgrade. Power supply is specified as 6–32 V DC.
Connector and pinout
79-way (mating connector #68086): the table below follows the manufacturer’s pinout for part #18047. Check cavity numbering and the manufacturer's connector view; the functional map is not a physical connector-face drawing. Blank cells retain the source's unspecified function; do not assign them by assumption. Inputs marked as optional need the appropriate enabled upgrade.
Pin
Name
Function
1
AV15
Analogue Voltage Input 15 (with 44 I/O upgrade)
2
AV16
Analogue Voltage Input 16 (with 44 I/O upgrade)
3
AV17
Analogue Voltage Input 17 (with 44 I/O upgrade)
4
AV18
Analogue Voltage Input 18 (with 44 I/O upgrade)
5
AV19
Analogue Voltage Input 19 (with 44 I/O upgrade)
6
0V
Sensor 0 V
7
BAT-
Battery Negative
8
BAT+
Battery Positive
9
AUX1
Auxiliary Output 1
10
AUX2
Auxiliary Output 2
11
AUX3
Auxiliary Output 3
12
AUX4
Auxiliary Output 4
13
AUX5
Auxiliary Output 5
14
AUX6
Auxiliary Output 6
15
RS232-2 TX
RS232-2 Transmit Output
16
RS232-2 RX
RS232-2 Receive Input
17
0V
Sensor 0 V
18
5V
Sensor 5 V
19
AV7
Analogue Voltage Input 7
20
AV8
Analogue Voltage Input 8
21
AV9
Analogue Voltage Input 9
22
AV10
Analogue Voltage Input 10
23
AV11
Analogue Voltage Input 11 (with 44 I/O upgrade)
24
AV12
Analogue Voltage Input 12 (with 44 I/O upgrade)
25
AV13
Analogue Voltage Input 13 (with 44 I/O upgrade)
26
AV14
Analogue Voltage Input 14 (with 44 I/O upgrade)
27
0V
Sensor 0 V
28
5V
Sensor 5 V
29
Reserved
30
Reserved
31
Reserved
32
Reserved
33
0V
Sensor 0 V
34
AT1
Analogue Temp Input 1
35
AT2
Analogue Temp Input 2
36
AT3
Analogue Temp Input 3
37
AT4
Analogue Temp Input 4
38
AT5
Analogue Temp Input 5 (with 44 I/O upgrade)
39
AT6
Analogue Temp Input 6 (with 44 I/O upgrade)
40
0V
Sensor 0 V
41
AT7
Analogue Temp Input 7 (with 44 I/O upgrade)
42
AT8
Analogue Temp Input 8 (with 44 I/O upgrade)
43
0V
Sensor 0 V
44
5V
Sensor 5 V
45
AV1
Analogue Voltage Input 1
46
AV2
Analogue Voltage Input 2
47
AV3
Analogue Voltage Input 3
48
AV4
Analogue Voltage Input 4
49
AV5
Analogue Voltage Input 5
50
AV6
Analogue Voltage Input 6
51
0V
Sensor 0 V
52
DIG1
Digital Input 1
53
DIG2
Digital Input 2
54
DIG3
Digital Input 3
55
DIG4
Digital Input 4
56
0V
Sensor 0 V
57
SW1
Switch Input 1
58
SW2
Switch Input 2
59
CAN4L
CAN 4 Low
60
CAN4H
CAN 4 High
61
0V
Sensor 0 V
62
8V
Sensor 8 V
63
SPD1
Speed Input 1
64
SPD2
Speed Input 2
65
SPD3
Speed Input 3
66
SPD4
Speed Input 4
67
E-TX+
Ethernet Transmit +
68
E-TX-
Ethernet Transmit -
69
AV20
Analogue Voltage Input 20 (with 44 I/O upgrade)
70
RS232-1 TX
RS232 Transmit Output
71
CAN3L
CAN 3 Low
72
CAN3H
CAN 3 High
73
CAN1L
CAN 1 Low
74
CAN1H
CAN 1 High
75
CAN2L
CAN 2 Low / RS232 Ground Input
76
CAN2H
CAN 2 High / RS232 Receive Input
77
E-RX+
Ethernet Receive +
78
E-RX-
Ethernet Receive -
79
RS232-1 RX
RS232 Receive Input
Wiring and configuration
Power and CAN example, functional schematic rather than connector geometry. Original Tuning Wiki illustration based on the MoTeC product pinout; verify the actual harness and matching ECU.
Use the correct connector, power and sensor return for this unit. Match CAN high and low to a compatible, correctly configured network and check existing termination. ECU channels, sensors and lap timing depend on the specific hardware, protocol, configuration and licensed options. Use manufacturer instructions for wire gauge, supply protection and continuity checks; do not connect vehicle battery voltage to a sensor reference output.
MoTeC i2 supports reviewing recorded data; Pro analysis and T2 telemetry require the applicable upgrades. A telemetry licence alone does not provide a radio or cellular connection. See the MoTeC manufacturer guide for family comparisons and references.
Revision 3: MoTeC L180
MoTeC L180 (MoTeC part #18047) is an enclosed motorsport data logger without an integrated driver display. The information here is specific to the cited part; check the label, hardware revision, options and vehicle protocol before connection.
Representative MoTeC L180 family unit; the pictured label reads 18040-09001, while this article describes part #18047. Image: MoTeC, reproduced with permission. Manufacturer product page and specifications.
Specifications and options
Enclosed logger without an integrated display; 250 MB internal recording and rates up to 1,000 samples per second.
The manufacturer describes USB logging as an upgrade that increases internal memory to 500 MB; verify enabled options on the specific #18047 unit.
Four configurable CAN buses, RS232, ten analogue voltage inputs and four temperature inputs as standard, with more via the 44 I/O upgrade. Power supply is specified as 6–32 V DC.
Connector and pinout
79-way (mating connector #68086): the table below follows the manufacturer’s pinout for part #18047. Check cavity numbering and the manufacturer's connector view; the functional map is not a physical connector-face drawing. Blank cells retain the source's unspecified function; do not assign them by assumption. Inputs marked as optional need the appropriate enabled upgrade.
Pin
Name
Function
1
AV15
Analogue Voltage Input 15 (with 44 I/O upgrade)
2
AV16
Analogue Voltage Input 16 (with 44 I/O upgrade)
3
AV17
Analogue Voltage Input 17 (with 44 I/O upgrade)
4
AV18
Analogue Voltage Input 18 (with 44 I/O upgrade)
5
AV19
Analogue Voltage Input 19 (with 44 I/O upgrade)
6
0V
Sensor 0 V
7
BAT-
Battery Negative
8
BAT+
Battery Positive
9
AUX1
Auxiliary Output 1
10
AUX2
Auxiliary Output 2
11
AUX3
Auxiliary Output 3
12
AUX4
Auxiliary Output 4
13
AUX5
Auxiliary Output 5
14
AUX6
Auxiliary Output 6
15
RS232-2 TX
RS232-2 Transmit Output
16
RS232-2 RX
RS232-2 Receive Input
17
0V
Sensor 0 V
18
5V
Sensor 5 V
19
AV7
Analogue Voltage Input 7
20
AV8
Analogue Voltage Input 8
21
AV9
Analogue Voltage Input 9
22
AV10
Analogue Voltage Input 10
23
AV11
Analogue Voltage Input 11 (with 44 I/O upgrade)
24
AV12
Analogue Voltage Input 12 (with 44 I/O upgrade)
25
AV13
Analogue Voltage Input 13 (with 44 I/O upgrade)
26
AV14
Analogue Voltage Input 14 (with 44 I/O upgrade)
27
0V
Sensor 0 V
28
5V
Sensor 5 V
29
Reserved
30
Reserved
31
Reserved
32
Reserved
33
0V
Sensor 0 V
34
AT1
Analogue Temp Input 1
35
AT2
Analogue Temp Input 2
36
AT3
Analogue Temp Input 3
37
AT4
Analogue Temp Input 4
38
AT5
Analogue Temp Input 5 (with 44 I/O upgrade)
39
AT6
Analogue Temp Input 6 (with 44 I/O upgrade)
40
0V
Sensor 0 V
41
AT7
Analogue Temp Input 7 (with 44 I/O upgrade)
42
AT8
Analogue Temp Input 8 (with 44 I/O upgrade)
43
0V
Sensor 0 V
44
5V
Sensor 5 V
45
AV1
Analogue Voltage Input 1
46
AV2
Analogue Voltage Input 2
47
AV3
Analogue Voltage Input 3
48
AV4
Analogue Voltage Input 4
49
AV5
Analogue Voltage Input 5
50
AV6
Analogue Voltage Input 6
51
0V
Sensor 0 V
52
DIG1
Digital Input 1
53
DIG2
Digital Input 2
54
DIG3
Digital Input 3
55
DIG4
Digital Input 4
56
0V
Sensor 0 V
57
SW1
Switch Input 1
58
SW2
Switch Input 2
59
CAN4L
CAN 4 Low
60
CAN4H
CAN 4 High
61
0V
Sensor 0 V
62
8V
Sensor 8 V
63
SPD1
Speed Input 1
64
SPD2
Speed Input 2
65
SPD3
Speed Input 3
66
SPD4
Speed Input 4
67
E-TX+
Ethernet Transmit +
68
E-TX-
Ethernet Transmit -
69
AV20
Analogue Voltage Input 20 (with 44 I/O upgrade)
70
RS232-1 TX
RS232 Transmit Output
71
CAN3L
CAN 3 Low
72
CAN3H
CAN 3 High
73
CAN1L
CAN 1 Low
74
CAN1H
CAN 1 High
75
CAN2L
CAN 2 Low / RS232 Ground Input
76
CAN2H
CAN 2 High / RS232 Receive Input
77
E-RX+
Ethernet Receive +
78
E-RX-
Ethernet Receive -
79
RS232-1 RX
RS232 Receive Input
Wiring and configuration
Power and CAN example, functional schematic rather than connector geometry. Original Tuning Wiki illustration based on the MoTeC product pinout; verify the actual harness and matching ECU.
Use the correct connector, power and sensor return for this unit. Match CAN high and low to a compatible, correctly configured network and check existing termination. ECU channels, sensors and lap timing depend on the specific hardware, protocol, configuration and licensed options. Use manufacturer instructions for wire gauge, supply protection and continuity checks; do not connect vehicle battery voltage to a sensor reference output.
MoTeC i2 supports reviewing recorded data; Pro analysis and T2 telemetry require the applicable upgrades. A telemetry licence alone does not provide a radio or cellular connection. See the MoTeC manufacturer guide for family comparisons and references.
Data analysis software
MoTeC i2 data analysis showing channel traces and gauges. Image: MoTeC, reproduced with permission; manufacturer image.
The L180 records data for later analysis; the exact memory, logging and Pro Analysis options depend on the unit and licence. MoTeC i2 reviews recorded channels in graphs and reports; i2 Pro features depend on the device upgrade or applicable software licence. See the manufacturer model and analysis comparison and i2 software and licence information.