ROTOTEST supplies hub-coupled powertrain dynamometers for vehicle development. Its Energy systems use controlled electrical machines, allowing appropriate configurations to absorb or supply power at the hubs.

History
ROTOTEST's history says it was founded in Sweden in January 1988, installed its first APG product in 1991 and introduced the VPA-RX in 2007. It dates the regenerative Energy line to 2008, the high-dynamic controller to 2018, and TOYO Corporation's acquisition to 2023.
Systems and operation
- APG and VPA-RX: earlier historical examples identified by the manufacturer. The ROTOTEST VPA-RX88 4WD datasheet specifies hydraulic multi-gear pumps, a common hydraulic rail and a fast control valve, plus a hub torque transducer and speed sensor. It is a hydraulic absorption system, distinct from the later Energy electrical machines.
- HUBDYNO 1005: a historical portable hydraulic hub system. A 2014 report on SuperFlow’s US distribution describes paired hub units, hydraulic connections and hydraulic-fluid cooling; a 2016 test-cell description identifies its load type as hydraulic. These are dated examples; do not assume a model is currently offered or that all ROTOTEST machines use the same absorber.
- Energy 500-250 4WD: a cited two-axle configuration for road-load simulation; the manufacturer lists differing axle capabilities.
- Energy 230-CP and 300-NVH: climate-protected and low-noise variants described by TOYO's ROTOTEST range.
An Energy hub unit connects to a driven wheel hub after wheel removal. Its four-quadrant electrical drive can apply motoring or absorbing torque in either rotational direction where the installed system supports it. It can simulate vehicle inertia and road load; the gearbox and final drive remain part of the vehicle. The manufacturer describes an integrated hub torque transducer. See electric dynamometers.
Controller and data software
The Energy 4WD datasheet names the HDC high-dynamic controller. The manufacturer's system description names DynoVision for operation and Datmon for measurement and reporting. Energy configurations include drives, electrical cabinets and a real-time controller; options and the permitted operating envelope depend on the particular system.
Part of Dynamometers and the manufacturers and suppliers directory. The products below are selected examples, not a complete catalogue; specifications, software and availability vary with generation and configuration.
Related guide: Hydraulic hub dynamometers: operation and models.