Diesel injection pump test benches drive a removed pump under controlled conditions and measure its performance against a pump-specific test plan. They help a diesel specialist investigate delivery, pressure, leakage, timing or control problems and validate an authorised repair. The required equipment differs substantially between older inline or distributor pumps and modern common-rail high-pressure pumps.

How a test bench works

An electric drive turns the pump through a specified coupling and mounting fixture. The bench supplies filtered calibration fluid, controls speed and other conditions, and measures the output using the appropriate graduated vessels or electronic quantity-measurement system. Pump-specific adapters, safety guards, cooling, external lubrication and electronic control may also be required. A test plan defines the pump identification, direction of rotation, speeds, settings, supply conditions, measurement points and permitted tolerances. Bench design and measuring equipment vary: the Bosch EPS 815 manual lists separate mechanical and electronic measuring systems, pump sets and control equipment.

Conventional inline and distributor pumps

Traditional inline pumps meter fuel through separate pumping elements, while a distributor pump meters and routes fuel to the cylinders through its own internal mechanism. A suitable bench can compare delivery by outlet, measure output at specified speeds and controls, and check relevant functions such as mechanical governor behaviour, timing or advance, housing pressure, return and leakage. What can actually be measured depends on the pump, fixtures and test plan. Beacon 12PSB catalogue; Bosch diesel component overview.

A pump with unequal outlet quantities or an incorrect governor response warrants investigation under the applicable repair procedure; it does not by itself identify which internal part has failed. Electronically controlled distributor pumps may need dedicated control equipment and software. A basic mechanical bench cannot automatically drive or validate electronic controls simply because the pump can be mounted to it.

Common-rail high-pressure pumps

Common-rail pumps supply a pressurised rail rather than individually metering each cylinder in the same way as a conventional inline pump. A suitable bench uses rated connections, a guarded rail or pressure-control assembly, pump-specific coupling and control hardware to test delivery and other characteristics at defined speed, supply pressure, rail pressure and control settings. The pump may need an external lubrication supply or specific valve timing and synchronisation. A pressure reading alone is not a complete pump test: delivered quantity, control response, return and leakage, supply conditions and the particular test plan matter. Bosch EPS 708; Hartridge HB401.

On the vehicle, low rail pressure can also result from supply restriction, air ingress, excessive injector return, a control or pressure-sensor problem, wiring or contamination. Investigate the system before assuming that the pump has failed. A bench pass or fail applies only to the pump and conditions tested; it does not establish the condition of the vehicle's injectors, wiring, rail or fuel tank.

Measurements and reports

Delivery quantity or flow: record the specified units and interval, drive speed, inlet and back-pressure, fluid temperature and control setting. Compare against the exact pump's test-plan limits. Outlet balance and timing: applicable conventional pumps may be checked for delivery differences between outlets and the specified phasing or start of delivery. Use the correct measuring lines and setup; differences in the test rig can affect comparison. Pressure and return: inlet, housing, rail, lubrication or return measurements apply only where the plan calls for them. A rail rated for a higher pressure than the test bench's operating limit must not be treated as permission to exceed that limit. Control and governor response: use the prescribed load, speed and control signals. Some systems need a dedicated controller and synchronisation to operate a metering valve correctly. Sealing and contamination: assess external leakage and evidence of contamination through the specified procedure. Metal debris can affect the wider system; repair decisions must follow the vehicle and component manufacturer's instructions.

Record the pump manufacturer and full part number, serial identification, bench and measuring system, plan and software version, fluid, calibration status, test points, limits and results. Differences in calibration fluid, temperature, pressure and method can make results from different rigs unsuitable for direct comparison. A generic test is not automatically equivalent to a manufacturer-authorised repair test.

Bench makes, models and part numbers

These examples include older machines and current product families. Machine numbers, optional kits and software identifiers are distinguished below. Features depend on configuration, software, pump family and region; a historical catalogue listing does not by itself establish availability or current support.

Bosch EPS 815 — 0 683 815 001 / 002 / 003: universal diesel component bench. A Bosch equipment catalogue lists 400 V, 200–240 V and 440–500 V versions respectively. The Bosch manual documents conventional, electronically controlled and common-rail test options. KMA 802, 0 683 802 001, is an electronic quantity-measurement system; VPM 844, 1 687 002 844, is a VP29/30/44 tester set; CRS 845H, 1 687 002 845, is a common-rail tester set. These are accessories, not interchangeable bench model numbers. Bosch EPS 625: conventional pump test bench for supported inline and distributor pumps. Bosch's diesel overview lists examples of mechanical and electronic governor applications. Verify the pump set and measuring equipment included with a used unit; do not assume common-rail capability. Bosch EPS 708 — 0 683 708 020 / 0 683 708 001: common-rail pump and injector bench. Bosch identifies these as 400 V versions with and without integrated cooling; other voltages have separate numbers. Bosch quotes testing up to 2,200 bar for the specified configuration. The separate pump kits include 1 687 010 346 for CP1/CP3, 1 687 010 390 for CP4 and 1 687 010 183 for specified third-party CP pumps. Hartridge AVM2-PC: modular pump and injector test platform supporting conventional rotary and inline pumps, common rail and other systems with appropriate application equipment. Authorised and all-makes functions depend on hardware and licence. HB401 is an automatic pressure-control upgrade, not the bench model. Hartridge AVM2-PC 3000 bar upgrade: a separate upgrade package for supported newer pump programmes. Listed components include HB435 guard enclosure, HB430 pump controller and HB429 automatic pressure controller. Do not attribute its 3,000 bar capability to an unmodified AVM2-PC. Hartridge CRp-PC: earlier common-rail pump test platform. The 2019 CRp-VDO documentation identifies A247A601 as a test-plan package and A247A600 as its associated application; valid software and licensing are required. These are software identifiers, not bench part numbers. Carbon Zapp MTBR-X: modular diesel and petrol component test system with common-rail pump test capability. Its product catalogue lists MTBRX-A, CZ-008713 as air-cooled and MTBRX-W, CZ-008783 as water-cooled, with a quoted 2,800 bar maximum for those configurations. The manufacturer brochure identifies synchronised control for specified pump families; confirm the exact hardware, test plans and authorisation. Beacon 12PSB and 12PSB-E: conventional diesel pump test-bench family. Beacon's catalogue describes delivery comparison, governor and distributor-pump checks for 12PSB; its 12PSB-E page identifies a mechanical-pump application. These model designations are used across a broader market: verify the actual manufacturer, electrical supply, included equipment and rated capability.

Workflow and selecting equipment

Identify the pump using its full manufacturer number and inspect the vehicle for supply faults, leakage, air and contamination. Preserve the relationship between the complaint and the test requested. Before installation, confirm the exact test plan, drive coupling, direction, guards, pump adapters, control electronics, calibration fluid and any external lubrication. Ensure software, licences and technician training cover the pump. Run the prescribed sequence and compare every applicable measurement against the specified limits. If the pump requires adjustment or repair, use the manufacturer's instructions and the appropriate authorised process; retest after work. Document results, restore the vehicle using its service procedure and investigate the full fuel system where contamination or metal debris is present. Confirm the original symptom is resolved.

When evaluating a used bench, check its measuring-system calibration, coupling and guard condition, pump-specific kits, compatible test plans, software support, required supply voltage, cooling, lubrication and spares. Compare speed, torque, flow and pressure capabilities under the intended test conditions; a maximum pressure figure alone does not prove adequate coverage or accuracy.

Safety

High-pressure fuel or calibration fluid can penetrate skin. Never loosen or tighten a pressurised connection or search for leaks with a hand. Use the specified guards, rated components and machine-specific shutdown and depressurisation procedure. Suspected fluid injection requires immediate emergency medical attention.Rotating couplings and shafts can cause serious injury. Install approved guards and interlocks, secure the pump correctly and isolate the drive before changing fixtures. Respect the bench's direction, speed and torque limits.Use approved test fluid, ventilation, eye protection and spill controls; manage waste and contamination in accordance with the equipment instructions. High-voltage control circuits and mains supplies require appropriate electrical precautions and trained personnel.

Related pages

Diesel injector test benches · Fuel pressure testers · Injector cleaning and flow testing machines · On-board and off-board diagnostics

See also: Automotive diesel injector nozzle and pop testers for mechanical nozzle checks, equipment and documented part numbers.See also: Automotive diesel fuel pressure and rail pressure test kits for supply-side and common-rail measurement methods, equipment and safety.See also: Automotive diesel fuel contamination and water-in-fuel testers for sampling, screening methods, equipment and diagnostic limits.See also: Automotive diesel fuel transfer pumps and priming tools for low-pressure supply, bleeding and transfer equipment and diagnostic uses.

Rendered revisions

Open each version to inspect formatting, tables and photographs.

Revision 1: Automotive diesel injection pump test benches

Diesel injection pump test benches drive a removed pump under controlled conditions and measure its performance against a pump-specific test plan. They help a diesel specialist investigate delivery, pressure, leakage, timing or control problems and validate an authorised repair. The required equipment differs substantially between older inline or distributor pumps and modern common-rail high-pressure pumps.

How a test bench works

An electric drive turns the pump through a specified coupling and mounting fixture. The bench supplies filtered calibration fluid, controls speed and other conditions, and measures the output using the appropriate graduated vessels or electronic quantity-measurement system. Pump-specific adapters, safety guards, cooling, external lubrication and electronic control may also be required. A test plan defines the pump identification, direction of rotation, speeds, settings, supply conditions, measurement points and permitted tolerances. Bench design and measuring equipment vary: the Bosch EPS 815 manual lists separate mechanical and electronic measuring systems, pump sets and control equipment.

Conventional inline and distributor pumps

Traditional inline pumps meter fuel through separate pumping elements, while a distributor pump meters and routes fuel to the cylinders through its own internal mechanism. A suitable bench can compare delivery by outlet, measure output at specified speeds and controls, and check relevant functions such as mechanical governor behaviour, timing or advance, housing pressure, return and leakage. What can actually be measured depends on the pump, fixtures and test plan. Beacon 12PSB catalogue; Bosch diesel component overview.

A pump with unequal outlet quantities or an incorrect governor response warrants investigation under the applicable repair procedure; it does not by itself identify which internal part has failed. Electronically controlled distributor pumps may need dedicated control equipment and software. A basic mechanical bench cannot automatically drive or validate electronic controls simply because the pump can be mounted to it.

Common-rail high-pressure pumps

Common-rail pumps supply a pressurised rail rather than individually metering each cylinder in the same way as a conventional inline pump. A suitable bench uses rated connections, a guarded rail or pressure-control assembly, pump-specific coupling and control hardware to test delivery and other characteristics at defined speed, supply pressure, rail pressure and control settings. The pump may need an external lubrication supply or specific valve timing and synchronisation. A pressure reading alone is not a complete pump test: delivered quantity, control response, return and leakage, supply conditions and the particular test plan matter. Bosch EPS 708; Hartridge HB401.

On the vehicle, low rail pressure can also result from supply restriction, air ingress, excessive injector return, a control or pressure-sensor problem, wiring or contamination. Investigate the system before assuming that the pump has failed. A bench pass or fail applies only to the pump and conditions tested; it does not establish the condition of the vehicle's injectors, wiring, rail or fuel tank.

Measurements and reports

  • Delivery quantity or flow: record the specified units and interval, drive speed, inlet and back-pressure, fluid temperature and control setting. Compare against the exact pump's test-plan limits.
  • Outlet balance and timing: applicable conventional pumps may be checked for delivery differences between outlets and the specified phasing or start of delivery. Use the correct measuring lines and setup; differences in the test rig can affect comparison.
  • Pressure and return: inlet, housing, rail, lubrication or return measurements apply only where the plan calls for them. A rail rated for a higher pressure than the test bench's operating limit must not be treated as permission to exceed that limit.
  • Control and governor response: use the prescribed load, speed and control signals. Some systems need a dedicated controller and synchronisation to operate a metering valve correctly.
  • Sealing and contamination: assess external leakage and evidence of contamination through the specified procedure. Metal debris can affect the wider system; repair decisions must follow the vehicle and component manufacturer's instructions.

Record the pump manufacturer and full part number, serial identification, bench and measuring system, plan and software version, fluid, calibration status, test points, limits and results. Differences in calibration fluid, temperature, pressure and method can make results from different rigs unsuitable for direct comparison. A generic test is not automatically equivalent to a manufacturer-authorised repair test.

Bench makes, models and part numbers

These examples include older machines and current product families. Machine numbers, optional kits and software identifiers are distinguished below. Features depend on configuration, software, pump family and region; a historical catalogue listing does not by itself establish availability or current support.

  • Bosch EPS 815 — 0 683 815 001 / 002 / 003: universal diesel component bench. A Bosch equipment catalogue lists 400 V, 200–240 V and 440–500 V versions respectively. The Bosch manual documents conventional, electronically controlled and common-rail test options. KMA 802, 0 683 802 001, is an electronic quantity-measurement system; VPM 844, 1 687 002 844, is a VP29/30/44 tester set; CRS 845H, 1 687 002 845, is a common-rail tester set. These are accessories, not interchangeable bench model numbers.
  • Bosch EPS 625: conventional pump test bench for supported inline and distributor pumps. Bosch's diesel overview lists examples of mechanical and electronic governor applications. Verify the pump set and measuring equipment included with a used unit; do not assume common-rail capability.
  • Bosch EPS 708 — 0 683 708 020 / 0 683 708 001: common-rail pump and injector bench. Bosch identifies these as 400 V versions with and without integrated cooling; other voltages have separate numbers. Bosch quotes testing up to 2,200 bar for the specified configuration. The separate pump kits include 1 687 010 346 for CP1/CP3, 1 687 010 390 for CP4 and 1 687 010 183 for specified third-party CP pumps.
  • Hartridge AVM2-PC: modular pump and injector test platform supporting conventional rotary and inline pumps, common rail and other systems with appropriate application equipment. Authorised and all-makes functions depend on hardware and licence. HB401 is an automatic pressure-control upgrade, not the bench model.
  • Hartridge AVM2-PC 3000 bar upgrade: a separate upgrade package for supported newer pump programmes. Listed components include HB435 guard enclosure, HB430 pump controller and HB429 automatic pressure controller. Do not attribute its 3,000 bar capability to an unmodified AVM2-PC.
  • Hartridge CRp-PC: earlier common-rail pump test platform. The 2019 CRp-VDO documentation identifies A247A601 as a test-plan package and A247A600 as its associated application; valid software and licensing are required. These are software identifiers, not bench part numbers.
  • Carbon Zapp MTBR-X: modular diesel and petrol component test system with common-rail pump test capability. Its product catalogue lists MTBRX-A, CZ-008713 as air-cooled and MTBRX-W, CZ-008783 as water-cooled, with a quoted 2,800 bar maximum for those configurations. The manufacturer brochure identifies synchronised control for specified pump families; confirm the exact hardware, test plans and authorisation.
  • Beacon 12PSB and 12PSB-E: conventional diesel pump test-bench family. Beacon's catalogue describes delivery comparison, governor and distributor-pump checks for 12PSB; its 12PSB-E page identifies a mechanical-pump application. These model designations are used across a broader market: verify the actual manufacturer, electrical supply, included equipment and rated capability.

Workflow and selecting equipment

  1. Identify the pump using its full manufacturer number and inspect the vehicle for supply faults, leakage, air and contamination. Preserve the relationship between the complaint and the test requested.
  2. Before installation, confirm the exact test plan, drive coupling, direction, guards, pump adapters, control electronics, calibration fluid and any external lubrication. Ensure software, licences and technician training cover the pump.
  3. Run the prescribed sequence and compare every applicable measurement against the specified limits. If the pump requires adjustment or repair, use the manufacturer's instructions and the appropriate authorised process; retest after work.
  4. Document results, restore the vehicle using its service procedure and investigate the full fuel system where contamination or metal debris is present. Confirm the original symptom is resolved.

When evaluating a used bench, check its measuring-system calibration, coupling and guard condition, pump-specific kits, compatible test plans, software support, required supply voltage, cooling, lubrication and spares. Compare speed, torque, flow and pressure capabilities under the intended test conditions; a maximum pressure figure alone does not prove adequate coverage or accuracy.

Safety

  • High-pressure fuel or calibration fluid can penetrate skin. Never loosen or tighten a pressurised connection or search for leaks with a hand. Use the specified guards, rated components and machine-specific shutdown and depressurisation procedure. Suspected fluid injection requires immediate emergency medical attention.
  • Rotating couplings and shafts can cause serious injury. Install approved guards and interlocks, secure the pump correctly and isolate the drive before changing fixtures. Respect the bench's direction, speed and torque limits.
  • Use approved test fluid, ventilation, eye protection and spill controls; manage waste and contamination in accordance with the equipment instructions. High-voltage control circuits and mains supplies require appropriate electrical precautions and trained personnel.

Related pages

Diesel injector test benches · Fuel pressure testers · Injector cleaning and flow testing machines · On-board and off-board diagnostics

Revision 5: Automotive diesel injection pump test benches

Diesel injection pump test benches drive a removed pump under controlled conditions and measure its performance against a pump-specific test plan. They help a diesel specialist investigate delivery, pressure, leakage, timing or control problems and validate an authorised repair. The required equipment differs substantially between older inline or distributor pumps and modern common-rail high-pressure pumps.

How a test bench works

An electric drive turns the pump through a specified coupling and mounting fixture. The bench supplies filtered calibration fluid, controls speed and other conditions, and measures the output using the appropriate graduated vessels or electronic quantity-measurement system. Pump-specific adapters, safety guards, cooling, external lubrication and electronic control may also be required. A test plan defines the pump identification, direction of rotation, speeds, settings, supply conditions, measurement points and permitted tolerances. Bench design and measuring equipment vary: the Bosch EPS 815 manual lists separate mechanical and electronic measuring systems, pump sets and control equipment.

Conventional inline and distributor pumps

Traditional inline pumps meter fuel through separate pumping elements, while a distributor pump meters and routes fuel to the cylinders through its own internal mechanism. A suitable bench can compare delivery by outlet, measure output at specified speeds and controls, and check relevant functions such as mechanical governor behaviour, timing or advance, housing pressure, return and leakage. What can actually be measured depends on the pump, fixtures and test plan. Beacon 12PSB catalogue; Bosch diesel component overview.

A pump with unequal outlet quantities or an incorrect governor response warrants investigation under the applicable repair procedure; it does not by itself identify which internal part has failed. Electronically controlled distributor pumps may need dedicated control equipment and software. A basic mechanical bench cannot automatically drive or validate electronic controls simply because the pump can be mounted to it.

Common-rail high-pressure pumps

Common-rail pumps supply a pressurised rail rather than individually metering each cylinder in the same way as a conventional inline pump. A suitable bench uses rated connections, a guarded rail or pressure-control assembly, pump-specific coupling and control hardware to test delivery and other characteristics at defined speed, supply pressure, rail pressure and control settings. The pump may need an external lubrication supply or specific valve timing and synchronisation. A pressure reading alone is not a complete pump test: delivered quantity, control response, return and leakage, supply conditions and the particular test plan matter. Bosch EPS 708; Hartridge HB401.

On the vehicle, low rail pressure can also result from supply restriction, air ingress, excessive injector return, a control or pressure-sensor problem, wiring or contamination. Investigate the system before assuming that the pump has failed. A bench pass or fail applies only to the pump and conditions tested; it does not establish the condition of the vehicle's injectors, wiring, rail or fuel tank.

Measurements and reports

  • Delivery quantity or flow: record the specified units and interval, drive speed, inlet and back-pressure, fluid temperature and control setting. Compare against the exact pump's test-plan limits.
  • Outlet balance and timing: applicable conventional pumps may be checked for delivery differences between outlets and the specified phasing or start of delivery. Use the correct measuring lines and setup; differences in the test rig can affect comparison.
  • Pressure and return: inlet, housing, rail, lubrication or return measurements apply only where the plan calls for them. A rail rated for a higher pressure than the test bench's operating limit must not be treated as permission to exceed that limit.
  • Control and governor response: use the prescribed load, speed and control signals. Some systems need a dedicated controller and synchronisation to operate a metering valve correctly.
  • Sealing and contamination: assess external leakage and evidence of contamination through the specified procedure. Metal debris can affect the wider system; repair decisions must follow the vehicle and component manufacturer's instructions.

Record the pump manufacturer and full part number, serial identification, bench and measuring system, plan and software version, fluid, calibration status, test points, limits and results. Differences in calibration fluid, temperature, pressure and method can make results from different rigs unsuitable for direct comparison. A generic test is not automatically equivalent to a manufacturer-authorised repair test.

Bench makes, models and part numbers

These examples include older machines and current product families. Machine numbers, optional kits and software identifiers are distinguished below. Features depend on configuration, software, pump family and region; a historical catalogue listing does not by itself establish availability or current support.

  • Bosch EPS 815 — 0 683 815 001 / 002 / 003: universal diesel component bench. A Bosch equipment catalogue lists 400 V, 200–240 V and 440–500 V versions respectively. The Bosch manual documents conventional, electronically controlled and common-rail test options. KMA 802, 0 683 802 001, is an electronic quantity-measurement system; VPM 844, 1 687 002 844, is a VP29/30/44 tester set; CRS 845H, 1 687 002 845, is a common-rail tester set. These are accessories, not interchangeable bench model numbers.
  • Bosch EPS 625: conventional pump test bench for supported inline and distributor pumps. Bosch's diesel overview lists examples of mechanical and electronic governor applications. Verify the pump set and measuring equipment included with a used unit; do not assume common-rail capability.
  • Bosch EPS 708 — 0 683 708 020 / 0 683 708 001: common-rail pump and injector bench. Bosch identifies these as 400 V versions with and without integrated cooling; other voltages have separate numbers. Bosch quotes testing up to 2,200 bar for the specified configuration. The separate pump kits include 1 687 010 346 for CP1/CP3, 1 687 010 390 for CP4 and 1 687 010 183 for specified third-party CP pumps.
  • Hartridge AVM2-PC: modular pump and injector test platform supporting conventional rotary and inline pumps, common rail and other systems with appropriate application equipment. Authorised and all-makes functions depend on hardware and licence. HB401 is an automatic pressure-control upgrade, not the bench model.
  • Hartridge AVM2-PC 3000 bar upgrade: a separate upgrade package for supported newer pump programmes. Listed components include HB435 guard enclosure, HB430 pump controller and HB429 automatic pressure controller. Do not attribute its 3,000 bar capability to an unmodified AVM2-PC.
  • Hartridge CRp-PC: earlier common-rail pump test platform. The 2019 CRp-VDO documentation identifies A247A601 as a test-plan package and A247A600 as its associated application; valid software and licensing are required. These are software identifiers, not bench part numbers.
  • Carbon Zapp MTBR-X: modular diesel and petrol component test system with common-rail pump test capability. Its product catalogue lists MTBRX-A, CZ-008713 as air-cooled and MTBRX-W, CZ-008783 as water-cooled, with a quoted 2,800 bar maximum for those configurations. The manufacturer brochure identifies synchronised control for specified pump families; confirm the exact hardware, test plans and authorisation.
  • Beacon 12PSB and 12PSB-E: conventional diesel pump test-bench family. Beacon's catalogue describes delivery comparison, governor and distributor-pump checks for 12PSB; its 12PSB-E page identifies a mechanical-pump application. These model designations are used across a broader market: verify the actual manufacturer, electrical supply, included equipment and rated capability.

Workflow and selecting equipment

  1. Identify the pump using its full manufacturer number and inspect the vehicle for supply faults, leakage, air and contamination. Preserve the relationship between the complaint and the test requested.
  2. Before installation, confirm the exact test plan, drive coupling, direction, guards, pump adapters, control electronics, calibration fluid and any external lubrication. Ensure software, licences and technician training cover the pump.
  3. Run the prescribed sequence and compare every applicable measurement against the specified limits. If the pump requires adjustment or repair, use the manufacturer's instructions and the appropriate authorised process; retest after work.
  4. Document results, restore the vehicle using its service procedure and investigate the full fuel system where contamination or metal debris is present. Confirm the original symptom is resolved.

When evaluating a used bench, check its measuring-system calibration, coupling and guard condition, pump-specific kits, compatible test plans, software support, required supply voltage, cooling, lubrication and spares. Compare speed, torque, flow and pressure capabilities under the intended test conditions; a maximum pressure figure alone does not prove adequate coverage or accuracy.

Safety

  • High-pressure fuel or calibration fluid can penetrate skin. Never loosen or tighten a pressurised connection or search for leaks with a hand. Use the specified guards, rated components and machine-specific shutdown and depressurisation procedure. Suspected fluid injection requires immediate emergency medical attention.
  • Rotating couplings and shafts can cause serious injury. Install approved guards and interlocks, secure the pump correctly and isolate the drive before changing fixtures. Respect the bench's direction, speed and torque limits.
  • Use approved test fluid, ventilation, eye protection and spill controls; manage waste and contamination in accordance with the equipment instructions. High-voltage control circuits and mains supplies require appropriate electrical precautions and trained personnel.

Related pages

Diesel injector test benches · Fuel pressure testers · Injector cleaning and flow testing machines · On-board and off-board diagnostics

See also: Automotive diesel injector nozzle and pop testers for mechanical nozzle checks, equipment and documented part numbers.

See also: Automotive diesel fuel pressure and rail pressure test kits for supply-side and common-rail measurement methods, equipment and safety.

See also: Automotive diesel fuel contamination and water-in-fuel testers for sampling, screening methods, equipment and diagnostic limits.

See also: Automotive diesel fuel transfer pumps and priming tools for low-pressure supply, bleeding and transfer equipment and diagnostic uses.