Port-injector calibration connects the ECU's requested fuel quantity to the actual injector and fuel system. A flow rating alone does not describe how the injector behaves during the short pulses used at idle. This guide concerns electronically controlled petrol port injection; direct-injection and diesel systems need their own data and control models.
Flow and pressure difference
Injector flow is specified at a stated pressure difference across the injector, not simply at a rail gauge reading. For a port injector, calculate differential pressure using rail pressure and inlet-manifold pressure expressed on the same pressure basis:
Injector differential pressure = fuel rail pressure − manifold pressure.
A manifold-referenced regulator is designed to vary rail pressure with manifold pressure so the difference remains approximately constant. A system with a fixed rail pressure relative to atmosphere can have a changing injector pressure difference as manifold pressure changes. Fuel delivery also depends on whether the pump and regulator maintain the intended pressure under load. Consult the ECU documentation for the particular pressure-sensor and regulator configuration. Haltech: injector flow
Illustrative example, with both readings expressed as gauge pressure: rail pressure 3.0 bar and manifold pressure −0.5 bar give a 3.5 bar injector differential. At 1.0 bar boost, if rail pressure remains at 3.0 bar gauge, the differential is 2.0 bar. This is an arithmetic illustration, not a recommended setting.
Dead time and short pulses
Injectors do not instantly reach full flow when switched on, and their flow changes as they open and close. ECUs commonly represent the resulting difference using an offset or dead-time model; the exact definition and table format are controller-specific. Supply voltage and pressure difference influence this behaviour. Use data for the exact injector, fuel pressure, electrical drive and ECU model wherever available. Incorrect offset data can make light-load and idle fuelling difficult to calibrate even when high-load fuelling appears acceptable. Haltech: injector dead time
At very short pulses, a single linear flow rate plus offset may not adequately describe delivery. Where the controller supports short-pulse or non-linear compensation, use data supplied in the format it expects. Do not transplant values from a different injector or assume one manufacturer's offset definition is interchangeable with another's.
Injection time and duty cycle
Injector duty cycle describes how much of the available time an output is commanded on. The calculation depends on how many pulses each injector receives per engine cycle and on the ECU's definition of its duty channel. A four-stroke cycle spans two crankshaft revolutions; Haltech documents both the 720-degree cycle and configurable injection events per cycle. Haltech: injection mode and events per cycle
For a simple illustration only, one 10 ms command per injector per four-stroke cycle at 6,000 rpm occupies half the 20 ms cycle, or 50% duty. Two 10 ms commands would fill that whole cycle. Real calculations must use the actual output strategy and the ECU's reported pulse-width definition. Duty cycle indicates available time, not proof of adequate fuel delivery: verify fuel pressure, pump supply and measured mixture too.
At high output the injector needs delivery margin; at idle it must also meter small pulses repeatably. There is no universal minimum pulse width or safe duty limit for every injector and driver. Haltech recommends about 80% or less at peak power for the Bosch injectors it discusses; treat that as product guidance, and use the supplier's limits for the actual hardware. Haltech: Bosch injectors
Practical validation
- Identify the injector by part number and obtain its documented flow, pressure and electrical characteristics. Confirm the ECU output is compatible with the injector and its required driver.
- Check fuel pressure and its reference across relevant operating conditions using equipment suited to the system. Confirm sensor units and whether readings are absolute, gauge or differential.
- Enter the supplier's flow and offset data using the controller's documented units and table definitions. Record the original calibration before changes.
- After mechanical and electrical checks, compare measured and commanded lambda and inspect pressure and battery voltage logs across idle, part load and controlled load. Investigate a pressure or sensor fault instead of concealing it with fuel-table corrections.
- Use suitable instrumentation and a controlled test environment for load testing. Stop if fuel pressure, mixture or other monitored conditions are unsafe for the engine.
Related reading: Petrol injector test results and flow calculations; Mixture tuning: AFR and lambda; ME7 fuel pressure and injector differential pressure.