Tuning Wiki

This is a historical revision. Read the current page or return to its history.

Page organisation in this revision
Page type
Technical article
Subject
Injectors
Parent
Section level
Applies to
No ECU-specific applicability
Tool groups
None
Manufacturers
None

Port-injector calibration connects the ECU's requested fuel quantity to the actual injector and fuel system. A flow rating alone does not describe how the injector behaves during the short pulses used at idle. This guide concerns electronically controlled petrol port injection; direct-injection and diesel systems need their own data and control models.

Flow and pressure difference

Injector flow is specified at a stated pressure difference across the injector, not simply at a rail gauge reading. For a port injector, calculate differential pressure using rail pressure and inlet-manifold pressure expressed on the same pressure basis:

Injector differential pressure = fuel rail pressure − manifold pressure.

A manifold-referenced regulator is designed to vary rail pressure with manifold pressure so the difference remains approximately constant. A system with a fixed rail pressure relative to atmosphere can have a changing injector pressure difference as manifold pressure changes. Fuel delivery also depends on whether the pump and regulator maintain the intended pressure under load. Consult the ECU documentation for the particular pressure-sensor and regulator configuration. Haltech: injector flow

Illustrative example, with both readings expressed as gauge pressure: rail pressure 3.0 bar and manifold pressure −0.5 bar give a 3.5 bar injector differential. At 1.0 bar boost, if rail pressure remains at 3.0 bar gauge, the differential is 2.0 bar. This is an arithmetic illustration, not a recommended setting.

Dead time and short pulses

Injectors do not instantly reach full flow when switched on, and their flow changes as they open and close. ECUs commonly represent the resulting difference using an offset or dead-time model; the exact definition and table format are controller-specific. Supply voltage and pressure difference influence this behaviour. Use data for the exact injector, fuel pressure, electrical drive and ECU model wherever available. Incorrect offset data can make light-load and idle fuelling difficult to calibrate even when high-load fuelling appears acceptable. Haltech: injector dead time

At very short pulses, a single linear flow rate plus offset may not adequately describe delivery. Where the controller supports short-pulse or non-linear compensation, use data supplied in the format it expects. Do not transplant values from a different injector or assume one manufacturer's offset definition is interchangeable with another's.

Practical validation

  1. Identify the injector by part number and obtain its documented flow, pressure and electrical characteristics. Confirm the ECU output is compatible with the injector and its required driver.
  2. Check fuel pressure and its reference across relevant operating conditions using equipment suited to the system. Confirm sensor units and whether readings are absolute, gauge or differential.
  3. Enter the supplier's flow and offset data using the controller's documented units and table definitions. Record the original calibration before changes.
  4. After mechanical and electrical checks, compare measured and commanded lambda and inspect pressure and battery voltage logs across idle, part load and controlled load. Investigate a pressure or sensor fault instead of concealing it with fuel-table corrections.
  5. Use suitable instrumentation and a controlled test environment for load testing. Stop if fuel pressure, mixture or other monitored conditions are unsafe for the engine.

Related reading: Petrol injector test results and flow calculations; Mixture tuning: AFR and lambda; ME7 fuel pressure and injector differential pressure.