Tuning Wiki

This is a historical revision. Read the current page or return to its history.

Page organisation in this revision
Page type
Technical article
Subject
Tuning
Parent
Simos 18
Applies to
Simos 18.1
Tool groups
None
Manufacturers
Volkswagen Group

Changes from revision 1 to revision 4

Removed text is struck through; added text is highlighted.

Transient enrichment is a separate path

A rapid load increase can need a short-lived fuel correction while air, fuel and wall-film behaviour change. The Simos 18 example below distinguishes the trigger, initial correction and its decay; it is not a single universal accelerator-pump table. Check injector scaling, fuel pressure, air-charge model, lambda target and the active DI/MPI combustion mode as well as the transient itself.

The named stock-related examples are from the community SC8S5031_C_OEM Simos 18.1 FMSP reference. Verify the exact ECU, ASW, CAL, hardware, array selection, mode, units, axes and scaling. The reference associates some prose with neighbouring fields incorrectly; the individual field description and axis definitions are research leads to verify in the matching A2L, not universal addresses or suggested values.

Trigger, initial factor and decay

ip_maf_sp_grd_min_trig_ae_di and ip_maf_sp_grd_min_trig_ae_mpi are minimum commanded-air-mass gradient thresholds for the respective DI and MPI paths, against rpm n_32 and corrected measured manifold pressure map_mes_cor. Idle-specific versions are ip_maf_sp_grd_min_trig_ae_is_di and ip_maf_sp_grd_min_trig_ae_is_mpi. ip_tps_av_grd_min_trig_ae and ip_tps_av_grd_min_trig_ae_is define throttle-angle gradient triggers, with other VVL-dependent variants. lc_tps_grd_ae is a selection switch for trigger calculation; verify its polarity and configuration in the target. ip_fac_map_mes_cor_ae is an altitude correction for measured manifold pressure, indexed by ambient pressure. ip_mff_fac_ae_ini_di and ip_mff_fac_ae_ini_mpi initialise the enrichment factor for DI and MPI, respectively, against rpm and corrected manifold pressure. ip_mff_fac_ae_ini_vvl_di and ip_mff_fac_ae_ini_vvl_mpi are valve-lift-related variants. These are correction factors, not injector pulse widths or absolute lambda targets. ip_fac_dec_mff_fac_ae_di and ip_fac_dec_mff_fac_ae_mpi set enrichment decrementation factors versus rpm and enrichment segment count seg_ctr_ae, with separate VVL variants. ip_fac_ae_fac_dec_ae_di and ip_fac_ae_fac_dec_ae_mpi provide additional decrement factors against rpm and m_air_cyl_sp in mg/stroke. The reference prose mentions MAP_SP, but its axis metadata identifies cylinder-air-mass setpoint; confirm the actual software. id_cycnr_mff_fac_ae_wait describes enrichment delay, indexed by rpm and corrected MAP. c_t_ast_min_ae is minimum time after start and c_t_inh_trig_ae a retrigger inhibition time. Engine-speed and other mode conditions can also gate the function.

Inhibition and transition checks: The FMSP reference describes ip_pq_max_ae as a maximum throttle pressure-ratio threshold for the acceleration-enrichment trigger, indexed by rpm. The described state machine enters an inhibited state above that threshold and uses c_pq_max_ae_hys for hysteresis. id_inh_trig_ae_vvl is an inhibition selector indexed by state_vvl_mng; its copied text refers to a different field, so verify the definition. lc_mff_fac_ae_inh_reac is described as an AE inhibition switch in REAC; confirm the active fuel-reactivation state and switch meaning in the target. These are gating conditions, not enrichment quantities or standalone diagnosis of a stumble.

When diagnosing a hesitation, first establish whether a trigger occurred, then whether the initial correction and its duration match the observed response. Changing a decay factor cannot correct a trigger that was never entered; do not assume that increasing every factor improves the transition.

Wall-film compensation is related but distinct

The separate FMSP wall-film reference describes models for both DI and port injection. ip_fac_mff_wf_hpdi[1][1] apportions high-pressure DI fuel to the wall-film models against rpm and basic fuel mass mff_bas in mg/stroke. ip_fac_mff_wf_mpi[1][1] is the corresponding port-fuel factor against rpm and intake-manifold pressure prs_im. ip_fac_mff_add_wf_pos[1] and ip_fac_mff_add_wf_neg[1] weight signed film-related corrections. Array selection and MPI applicability depend on the actual combustion mode and hardware.

mff_add_wf and modelled film masses are runtime estimates, not directly measured film or calibration tables. Fuel composition, injector characteristics and cold operation can change the response, so a correction derived from one steady-state pull should not be applied indiscriminately to all transients.

For manifold and chamber model factors, evaporation curves, after-start fade and logging, see Simos 18 wall-film fuel compensation.

Logging and validation

Where supported, log accelerator and throttle positions, rpm, actual and requested air charge or pressure, DI/MPI mode and injection, fuel pressure target and actual, lambda target and measured lambda, ignition, knock, misfire and relevant temperatures. The reference lists lv_trig_ae, lv_enr_state_ae, mff_fac_ae, seg_ctr_ae, maf_sp_grd_ae and its threshold, and tps_av_grd and its threshold as runtime signals. In this specific definition state_ae encodes trigger calculation, enrichment and inhibition as 0, 1 and 2; verify the logger definition before decoding.

lv_lam_stop_ae is a lambda-controller stop flag in the reference, not proof that the sensor has stopped measuring. The described controller can pause and later resume around enrichment. Consider sensor readiness, exhaust transport and logging delays before aligning a lambda excursion with a pedal event. Compare repeatable small and larger tip-ins at relevant temperatures and load, and verify the steady-state fuel and air model first.

Sustained full-load enrichment is a different strategy. The community HP Tuners table list uses display names such as Target Lambda at Full Load; those are product labels, not the transient FMSP identifiers above.

Mixture feedback guides: lambda control · fuel trim and adaptation.

Related: deceleration fuel cut · cold start · MPI combustion modes · air charge · throttle control. References reviewed 17 November 2026.

Rendered revisions

Open each version to inspect formatting, tables and photographs.

Revision 1: Simos 18 acceleration enrichment tuning

Transient enrichment is a separate path

A rapid load increase can need a short-lived fuel correction while air, fuel and wall-film behaviour change. The Simos 18 example below distinguishes the trigger, initial correction and its decay; it is not a single universal accelerator-pump table. Check injector scaling, fuel pressure, air-charge model, lambda target and the active DI/MPI combustion mode as well as the transient itself.

The named stock-related examples are from the community SC8S5031_C_OEM Simos 18.1 FMSP reference. Verify the exact ECU, ASW, CAL, hardware, array selection, mode, units, axes and scaling. The reference associates some prose with neighbouring fields incorrectly; the individual field description and axis definitions are research leads to verify in the matching A2L, not universal addresses or suggested values.

Trigger, initial factor and decay

  • ip_maf_sp_grd_min_trig_ae_di and ip_maf_sp_grd_min_trig_ae_mpi are minimum commanded-air-mass gradient thresholds for the respective DI and MPI paths, against rpm n_32 and corrected measured manifold pressure map_mes_cor. Idle-specific versions are ip_maf_sp_grd_min_trig_ae_is_di and ip_maf_sp_grd_min_trig_ae_is_mpi.
  • ip_tps_av_grd_min_trig_ae and ip_tps_av_grd_min_trig_ae_is define throttle-angle gradient triggers, with other VVL-dependent variants. lc_tps_grd_ae is a selection switch for trigger calculation; verify its polarity and configuration in the target. ip_fac_map_mes_cor_ae is an altitude correction for measured manifold pressure, indexed by ambient pressure.
  • ip_mff_fac_ae_ini_di and ip_mff_fac_ae_ini_mpi initialise the enrichment factor for DI and MPI, respectively, against rpm and corrected manifold pressure. ip_mff_fac_ae_ini_vvl_di and ip_mff_fac_ae_ini_vvl_mpi are valve-lift-related variants. These are correction factors, not injector pulse widths or absolute lambda targets.
  • ip_fac_dec_mff_fac_ae_di and ip_fac_dec_mff_fac_ae_mpi set enrichment decrementation factors versus rpm and enrichment segment count seg_ctr_ae, with separate VVL variants. ip_fac_ae_fac_dec_ae_di and ip_fac_ae_fac_dec_ae_mpi provide additional decrement factors against rpm and m_air_cyl_sp in mg/stroke. The reference prose mentions MAP_SP, but its axis metadata identifies cylinder-air-mass setpoint; confirm the actual software.
  • id_cycnr_mff_fac_ae_wait describes enrichment delay, indexed by rpm and corrected MAP. c_t_ast_min_ae is minimum time after start and c_t_inh_trig_ae a retrigger inhibition time. Engine-speed and other mode conditions can also gate the function.

When diagnosing a hesitation, first establish whether a trigger occurred, then whether the initial correction and its duration match the observed response. Changing a decay factor cannot correct a trigger that was never entered; do not assume that increasing every factor improves the transition.

Wall-film compensation is related but distinct

The separate FMSP wall-film reference describes models for both DI and port injection. ip_fac_mff_wf_hpdi[1][1] apportions high-pressure DI fuel to the wall-film models against rpm and basic fuel mass mff_bas in mg/stroke. ip_fac_mff_wf_mpi[1][1] is the corresponding port-fuel factor against rpm and intake-manifold pressure prs_im. ip_fac_mff_add_wf_pos[1] and ip_fac_mff_add_wf_neg[1] weight signed film-related corrections. Array selection and MPI applicability depend on the actual combustion mode and hardware.

mff_add_wf and modelled film masses are runtime estimates, not directly measured film or calibration tables. Fuel composition, injector characteristics and cold operation can change the response, so a correction derived from one steady-state pull should not be applied indiscriminately to all transients.

Logging and validation

Where supported, log accelerator and throttle positions, rpm, actual and requested air charge or pressure, DI/MPI mode and injection, fuel pressure target and actual, lambda target and measured lambda, ignition, knock, misfire and relevant temperatures. The reference lists lv_trig_ae, lv_enr_state_ae, mff_fac_ae, seg_ctr_ae, maf_sp_grd_ae and its threshold, and tps_av_grd and its threshold as runtime signals. In this specific definition state_ae encodes trigger calculation, enrichment and inhibition as 0, 1 and 2; verify the logger definition before decoding.

lv_lam_stop_ae is a lambda-controller stop flag in the reference, not proof that the sensor has stopped measuring. The described controller can pause and later resume around enrichment. Consider sensor readiness, exhaust transport and logging delays before aligning a lambda excursion with a pedal event. Compare repeatable small and larger tip-ins at relevant temperatures and load, and verify the steady-state fuel and air model first.

Sustained full-load enrichment is a different strategy. The community HP Tuners table list uses display names such as Target Lambda at Full Load; those are product labels, not the transient FMSP identifiers above.

Related: deceleration fuel cut · cold start · MPI combustion modes · air charge · throttle control. References reviewed 17 November 2026.

Revision 4: Simos 18 acceleration enrichment tuning

Transient enrichment is a separate path

A rapid load increase can need a short-lived fuel correction while air, fuel and wall-film behaviour change. The Simos 18 example below distinguishes the trigger, initial correction and its decay; it is not a single universal accelerator-pump table. Check injector scaling, fuel pressure, air-charge model, lambda target and the active DI/MPI combustion mode as well as the transient itself.

The named stock-related examples are from the community SC8S5031_C_OEM Simos 18.1 FMSP reference. Verify the exact ECU, ASW, CAL, hardware, array selection, mode, units, axes and scaling. The reference associates some prose with neighbouring fields incorrectly; the individual field description and axis definitions are research leads to verify in the matching A2L, not universal addresses or suggested values.

Trigger, initial factor and decay

  • ip_maf_sp_grd_min_trig_ae_di and ip_maf_sp_grd_min_trig_ae_mpi are minimum commanded-air-mass gradient thresholds for the respective DI and MPI paths, against rpm n_32 and corrected measured manifold pressure map_mes_cor. Idle-specific versions are ip_maf_sp_grd_min_trig_ae_is_di and ip_maf_sp_grd_min_trig_ae_is_mpi.
  • ip_tps_av_grd_min_trig_ae and ip_tps_av_grd_min_trig_ae_is define throttle-angle gradient triggers, with other VVL-dependent variants. lc_tps_grd_ae is a selection switch for trigger calculation; verify its polarity and configuration in the target. ip_fac_map_mes_cor_ae is an altitude correction for measured manifold pressure, indexed by ambient pressure.
  • ip_mff_fac_ae_ini_di and ip_mff_fac_ae_ini_mpi initialise the enrichment factor for DI and MPI, respectively, against rpm and corrected manifold pressure. ip_mff_fac_ae_ini_vvl_di and ip_mff_fac_ae_ini_vvl_mpi are valve-lift-related variants. These are correction factors, not injector pulse widths or absolute lambda targets.
  • ip_fac_dec_mff_fac_ae_di and ip_fac_dec_mff_fac_ae_mpi set enrichment decrementation factors versus rpm and enrichment segment count seg_ctr_ae, with separate VVL variants. ip_fac_ae_fac_dec_ae_di and ip_fac_ae_fac_dec_ae_mpi provide additional decrement factors against rpm and m_air_cyl_sp in mg/stroke. The reference prose mentions MAP_SP, but its axis metadata identifies cylinder-air-mass setpoint; confirm the actual software.
  • id_cycnr_mff_fac_ae_wait describes enrichment delay, indexed by rpm and corrected MAP. c_t_ast_min_ae is minimum time after start and c_t_inh_trig_ae a retrigger inhibition time. Engine-speed and other mode conditions can also gate the function.

Inhibition and transition checks: The FMSP reference describes ip_pq_max_ae as a maximum throttle pressure-ratio threshold for the acceleration-enrichment trigger, indexed by rpm. The described state machine enters an inhibited state above that threshold and uses c_pq_max_ae_hys for hysteresis. id_inh_trig_ae_vvl is an inhibition selector indexed by state_vvl_mng; its copied text refers to a different field, so verify the definition. lc_mff_fac_ae_inh_reac is described as an AE inhibition switch in REAC; confirm the active fuel-reactivation state and switch meaning in the target. These are gating conditions, not enrichment quantities or standalone diagnosis of a stumble.

When diagnosing a hesitation, first establish whether a trigger occurred, then whether the initial correction and its duration match the observed response. Changing a decay factor cannot correct a trigger that was never entered; do not assume that increasing every factor improves the transition.

Wall-film compensation is related but distinct

The separate FMSP wall-film reference describes models for both DI and port injection. ip_fac_mff_wf_hpdi[1][1] apportions high-pressure DI fuel to the wall-film models against rpm and basic fuel mass mff_bas in mg/stroke. ip_fac_mff_wf_mpi[1][1] is the corresponding port-fuel factor against rpm and intake-manifold pressure prs_im. ip_fac_mff_add_wf_pos[1] and ip_fac_mff_add_wf_neg[1] weight signed film-related corrections. Array selection and MPI applicability depend on the actual combustion mode and hardware.

mff_add_wf and modelled film masses are runtime estimates, not directly measured film or calibration tables. Fuel composition, injector characteristics and cold operation can change the response, so a correction derived from one steady-state pull should not be applied indiscriminately to all transients.

For manifold and chamber model factors, evaporation curves, after-start fade and logging, see Simos 18 wall-film fuel compensation.

Logging and validation

Where supported, log accelerator and throttle positions, rpm, actual and requested air charge or pressure, DI/MPI mode and injection, fuel pressure target and actual, lambda target and measured lambda, ignition, knock, misfire and relevant temperatures. The reference lists lv_trig_ae, lv_enr_state_ae, mff_fac_ae, seg_ctr_ae, maf_sp_grd_ae and its threshold, and tps_av_grd and its threshold as runtime signals. In this specific definition state_ae encodes trigger calculation, enrichment and inhibition as 0, 1 and 2; verify the logger definition before decoding.

lv_lam_stop_ae is a lambda-controller stop flag in the reference, not proof that the sensor has stopped measuring. The described controller can pause and later resume around enrichment. Consider sensor readiness, exhaust transport and logging delays before aligning a lambda excursion with a pedal event. Compare repeatable small and larger tip-ins at relevant temperatures and load, and verify the steady-state fuel and air model first.

Sustained full-load enrichment is a different strategy. The community HP Tuners table list uses display names such as Target Lambda at Full Load; those are product labels, not the transient FMSP identifiers above.

Mixture feedback guides: lambda control · fuel trim and adaptation.

Related: deceleration fuel cut · cold start · MPI combustion modes · air charge · throttle control. References reviewed 17 November 2026.