Selected positions on the 58-way HECU in the AUMOVIO MK 100 UHP Technical Manual v2.1, ABS-only diagram figure 17 and pin details section 6.3. This is the manufacturer’s UHP wiring scope, not a generic MK 100 or a custom vehicle-harness allocation. Unlisted cavities are not assigned here. Identify connector orientation using figure 18 in the cited source.
| Pin | Function in ABS-only diagram |
|---|---|
| 1 | KL30_P battery supply; 40 A fuse |
| 45 | KL30_V battery supply; 40 A fuse |
| 34 | KL15 ignition supply; 5 A fuse in diagram |
| 14 | Ground |
| 58 | Ground |
| 31 | Vehicle CAN high |
| 16 | Vehicle CAN low |
| 28 | Baud-rate switch ground |
| 41 | Baud-rate switch signal |
| 27 | Private CAN high |
| 42 | Private CAN low |
| 11 | Rear right wheel speed signal |
| 10 | Rear right wheel speed ground |
| 9 | Front left wheel speed signal |
| 8 | Front left wheel speed ground |
| 7 | Rear left wheel speed signal |
| 6 | Rear left wheel speed ground |
| 5 | Front right wheel speed signal |
| 4 | Front right wheel speed ground |
| 53 | PS20 pressure sensor SENSEEP |
| 40 | PS20 pressure sensor ground |
| 55 | PS20 pressure sensor signal |
| 47 | ABS warning lamp output |
| 56 | DTC warning lamp output |
| 57 | Vehicle-speed TACHY_OUT |
| 43 | Brake light output |
| 22 | ABS mode switch SENSEEP |
| 29 | ABS mode switch ground |
| 23 | ABS mode switch signal |
| 54 | ABS off switch |
For this documented configuration, both baud-rate switch pins open selects 1 Mbit/s; bridging pins 28 and 41 selects 500 kbit/s. Vehicle CAN and the IMU/private CAN are separate. The manual identifies 40 A MAXI fuses for the main battery supplies. See the exact manual for electrical limits, wiring, commissioning and software requirements.
Source: AUMOVIO MK 100 UHP technical manual v2.1, pages 22 and 36.