Scope: Unless a product or other software is named, engineering identifiers are examples from the community SC8S5031_C_OEM Simos 18.1 reference. Verify the actual ECU/ASW, sensor arrangement, definitions, units, indices, selectors and installed patches. Some extracted function captions conflict with the A2L labels; names, addresses or numbers cannot be transferred blindly. SC8S5031 reference.

Pedal request and throttle are different

Pedal position enters the driver's torque request; the ECU then coordinates torque, air and actuator controls. A fully pressed pedal is not a direct mechanical throttle command, and partial plate movement alone does not establish a fault or the active torque limiter. Intake-manifold pressure, pressure upstream of the throttle, boost control, shift and traction requests and system protections all provide context. EcuTek identifies throttle as part of the slow path for its EA888 example. See also torque model calibration.

Throttle area and setpoint maps

  • ip_ar_thr_bas is the reduced throttle-area characteristic against throttle position tps_seg, with reduced area in cm² in the SC8S5031 throttle-area reference. It represents the throttle's flow characteristic, not a pedal map.
  • ip_tps_sp_mdl_bas is the associated inverse characteristic converting reduced throttle-area request ar_thr_sp_mmv to a position setpoint in degrees TPS. It is not a driver-pedal-to-plate table. Confirm sensor reference, angle convention and actual throttle geometry. INSY throttle setpoint.
  • ip_tps_sp_mdl_max is an example maximum throttle-position setpoint with ignition on, against engine speed and cylinder air-mass setpoint m_air_cyl_sp, in degrees TPS. It is a modeled maximum, not an unconditional command or actual opening.
  • ip_fac_amp_cor_tps_sp_mdl_max is an ambient-pressure correction factor versus ambient pressure for the maximum setpoint in the same example. The final limit can involve additional selection and checks.
  • ip_p_ctl_tps_sp_mdl and ip_i_ctl_tps_sp_mdl are P- and I-controller gain maps against speed and a manifold-pressure difference. Their extracted neighbouring captions are mismatched; confirm the A2L and actual control implementation. They are controller gains, not desired plate angles.

Selection, feedback and diagnosis

The THRO setpoint-selection reference lists c_tps_sp_max and c_tps_sp_min as upper and lower position-setpoint limits. ip_tps_sp_lgrd_st is a transient-after-start gradient calibration, not a general pedal-response map. Relevant hardware, adaptation, plausibility and fault checks remain part of the complete control system.

In INSY throttle setpoint calculation, tps_sp_mdl_bas is a runtime setpoint before the maximum check, tps_sp_mdl_p_ctl and tps_sp_mdl_i_ctl are runtime control contributions, and prs_im_dif_tps_sp_ctl is the pressure-difference input to the controller. These are measurements, not editable maps; a preliminary setpoint is not proof of the final plate position. The THRO actuator diagnosis lists ip_tps_dif_err_max as a diagnostic allowed-deviation calibration. Its displayed axis metadata is ambiguous, so verify it against the matching definition; it is not an opening target.

Interpreting a log

For supported MQB applications COBB calls the pedal channel Accelerator Pedal Position, the commanded plate channel TPS Set Point and the sensor channel TPS. Log these with rpm, gear, torque request and limitation source, manifold pressure and target, upstream-throttle pressure and target, air-mass request/estimate, wastegate state, lambda and faults. Check the logger's scaling, units and timestamps before comparing channels.

If the commanded angle changes with the sensor following it, investigate the corresponding pressure, torque and operating-state request. If sensor feedback consistently differs from the command, inspect the actuator, supply, sensor plausibility and relevant faults with the appropriate service procedure. These are diagnostic branches, not proof of any one cause. Compare pressure upstream and downstream of the throttle using the same absolute/gauge convention; a partly open plate does not by itself quantify airflow or lost power.

Related: air charge modelling · throttle control · torque model · wastegate and boost · camshaft timing · valve lift · log diagnosis.