Page organisation in this revision
- Page type
- Technical article
- Subject
- ABS / DSC
- Parent
- Davis Technologies CT2-SL
- Applies to
- No ECU-specific applicability
- Tool groups
- None
- Manufacturers
- Davis Technologies
Changes from revision 1 to revision 1
Removed text is struck through; added text is highlighted.
Davis Technologies CT2-SL · Davis Technologies traction control systems
Scope
Davis CT Series instructions, Appendix B, printed page 32, describe the three-pin Weather Pack plug option for CT-1, CT2-SL and CT3-SL series units. This page is scoped to CT2-SL with that three-pin option. Identify terminals by their moulded letters and confirm the installed ignition and harness against the manufacturer's illustration before wiring.
Weather Pack terminalWireConnectionNano-Fit reference in manualARedBattery positive1BBlackBattery negative4CPurple or whitePositive distributor pickup wire7
The same manual separately shows a four-pin option, where C is the negative distributor pickup and D is the positive pickup. Do not transfer the three-pin terminal letters to that connector. Use the manufacturer’s ignition-specific diagram and settings; the referenced Nano-Fit numbers identify the corresponding terminals and are not Weather Pack cavity numbers.
Source
Davis Technologies CT Series instructions, Appendix B, printed pages 32–33.
Rendered revisions
Open each version to inspect formatting, tables and photographs.
Revision 1: Davis Technologies CT2-SL three-pin Weather Pack pinout
Davis Technologies CT2-SL · Davis Technologies traction control systems
Scope
Davis CT Series instructions, Appendix B, printed page 32, describe the three-pin Weather Pack plug option for CT-1, CT2-SL and CT3-SL series units. This page is scoped to CT2-SL with that three-pin option. Identify terminals by their moulded letters and confirm the installed ignition and harness against the manufacturer's illustration before wiring.
| Weather Pack terminal | Wire | Connection | Nano-Fit reference in manual |
|---|
| A | Red | Battery positive | 1 |
| B | Black | Battery negative | 4 |
| C | Purple or white | Positive distributor pickup wire | 7 |
The same manual separately shows a four-pin option, where C is the negative distributor pickup and D is the positive pickup. Do not transfer the three-pin terminal letters to that connector. Use the manufacturer’s ignition-specific diagram and settings; the referenced Nano-Fit numbers identify the corresponding terminals and are not Weather Pack cavity numbers.
Source
Davis Technologies CT Series instructions, Appendix B, printed pages 32–33.
Revision 1: Davis Technologies CT2-SL three-pin Weather Pack pinout
Davis Technologies CT2-SL · Davis Technologies traction control systems
Scope
Davis CT Series instructions, Appendix B, printed page 32, describe the three-pin Weather Pack plug option for CT-1, CT2-SL and CT3-SL series units. This page is scoped to CT2-SL with that three-pin option. Identify terminals by their moulded letters and confirm the installed ignition and harness against the manufacturer's illustration before wiring.
| Weather Pack terminal | Wire | Connection | Nano-Fit reference in manual |
|---|
| A | Red | Battery positive | 1 |
| B | Black | Battery negative | 4 |
| C | Purple or white | Positive distributor pickup wire | 7 |
The same manual separately shows a four-pin option, where C is the negative distributor pickup and D is the positive pickup. Do not transfer the three-pin terminal letters to that connector. Use the manufacturer’s ignition-specific diagram and settings; the referenced Nano-Fit numbers identify the corresponding terminals and are not Weather Pack cavity numbers.
Source
Davis Technologies CT Series instructions, Appendix B, printed pages 32–33.