Tuning Wiki

This is a historical revision. Read the current page or return to its history.

Page organisation in this revision
Page type
Technical article
Subject
Tuning
Parent
Simos 18
Applies to
Simos 18.1
Tool groups
None
Manufacturers
Volkswagen Group

Applicability: The engineering identifiers below are from the community SC8S5031_C_OEM Simos 18.1 cross-reference unless another source is named. Identify the engine, hardware, ECU software, calibration and installed patches; match the A2L, axes, units, signs, indices and selectors. Extracted descriptions sometimes conflict. Values, addresses and states from another software version are not a calibration for this vehicle. SC8S5031 reference.

What switches?

Switchable valve lift selects between discrete cam profiles; it does not replace continuous intake/exhaust cam phasing. Volkswagen's SSP 522, pages 13–15 shows four sliding exhaust-cam pieces and electrical actuators on its CHHA/CHHB examples. EcuTek describes exhaust-only AVS on the EA888 Gen 3 MQB applications covered by its EA888 guide. Confirm the engine code and hardware rather than assuming all Simos 18 engines share that arrangement.

Request, hysteresis and delay

  • ip_vlft_sp is a binary valve-lift setpoint map in the SC8S5031 VVLI reference, with engine speed and torque-derived air-mass setpoint maf_sp_tqi as axes. It is not simply a fixed RPM switch or measured-airflow table. The table describes 1 as LFT_1 and 0 as standard; an extracted narrative elsewhere on the same page conflicts about low-lift polarity. Verify the target's actual semantics and hardware instead of copying a value.
  • c_n_hys_vlft_1_sp and c_maf_sp_tqi_hys_vlft_1_sp are speed and air-mass hysteresis calibrations in the example. They can make the switch-back boundary different from the outgoing boundary, helping avoid repeated switching near a threshold.
  • ip_t_dly_vlft_sp[1] is a lift-request transition delay versus engine speed and coolant temperature in the example; id_idx_gear_t_dly_vlft_sp is a gear-dependent delay-map selector. Delay direction depends on the strategy and selector. The source cautions that switching must happen in time; no delay or hysteresis values should be copied between applications.
  • ip_fac_maf_sp_cor_vvl is an altitude-related correction factor for the setpoint calculation, with speed and ambient-pressure axes in the displayed example. The source contains an inconsistent attached caption, so verify in the matching ASW.

Transition coordination

ip_tq_tran_vlft_stnd_ofs is a torque offset for transition to standard lift, versus engine speed and predicted cylinder air mass in the VVLI state-coordination example. It is a transition-related torque calibration, not the normal lift request table. c_n_max_vvl_ctl is a maximum-speed threshold associated with control to LFT_1 in the controller reference; it is distinct from the normal request boundary and depends on the hardware.

Actuator timing is a different calibration

The VVLI timing reference lists ip_t_dly_swi_vvl_acr as actuator dead time versus battery voltage and modelled actuator reference temperature, and ip_t_swi_vvl_acr as total actuator switching time versus speed and reference temperature. The output is milliseconds in that example. These describe actuator behaviour, not the load/RPM switch boundary. t_dly_swi_vvl_acr is a runtime measurement. Confirm actual actuator characteristics and preserve switching protections.

Request versus realised state

vlft_sp_req, lv_inh_vlft_1 and lv_inh_vlft_stnd appear as runtime request/inhibition signals in the setpoint reference. The request-coordination reference lists lv_vvl_swi_auth and lv_vvl_swi_ctl_inh for switching authorisation and inhibition. state_vvl_chg is a cylinder bitmask of actuators required to switch, not proof they achieved the new profile. VVLI controller. The community cross-reference labels a vlft_sp_req logger PID as a lift position, but describes the underlying signal as an uncorrected request; do not treat it as a physically confirmed position. Availability, state encoding and cylinder indexing must be checked.

For its supported MQB applications, COBB defines Valve Lift Set Point as a request and Valve Lift State as a high-lift state using its own displayed encoding. Do not infer the same polarity as ip_vlft_sp or assume that the display independently senses physical position. Compare request, reported state and relevant diagnostics.

Evaluating a transition

Log speed, torque-related air-mass request and actual, both cam position requests and actuals, lift request/state, intake-flap state, ignition and knock, lambda, boost and faults through both directions of a switch. Compare at similar temperatures and loads, including transient and partial-load operation. A change in lift may select different torque, air and ignition model tables; a step or hesitation can involve several systems. EcuTek describes determining transition points by testing on its documented engine; its example is not a universal changeover RPM. EcuTek EA888 guide.

Related: camshaft timing · valve lift tuning · torque model · ignition timing · bigger turbos · log diagnosis.