Removed text is struck through; added text is highlighted.
The standard ADU7 combines a seven-inch screen and USB data logging. ECUMASTER lists brightness of 1,000 cd/m², weight 732 g and revision-dependent enclosure protection (Rev.2 IP65). The standard connector is not the Autosport connector. ECUMASTER ADU specification.
ECUMASTER ADU7 dash logger. Image: ECUMASTER; reproduced with permission. Manufacturer source.
Data analysis softwareData Master 2024.4 analysis showing channel traces, scatter plot and tables. Image: ECUMASTER, reproduced with permission; manufacturer release announcement.Record the configured channels to the ADU's USB drive, then open the file in ECUMASTER Data Master to compare laps, graph channels and analyse logged data. Video synchronisation requires a suitable recording. Download Data Master and the manual; ADU USB logging instructions. Configure the ADU using its separate ADU software package. Available channels depend on the configured logger, sensors and ECU data.See the ECUMASTER analysis software overview.
Specifications and logging
The ADU combines a configurable TFT dashboard, alarms and 15 RGB LEDs with acquisition of vehicle and sensor data. Its inputs include eight 0–5 V analogue channels, eight digital/frequency channels, two low-side outputs, a 0–5 V analogue output, CAN 2.0 A/B and RS232. GPS lap timing requires a suitable external GPS source. The manufacturer’s specification gives an operating range of 6–22 V and 3-axis accelerometer and gyroscope.
Channels can be logged to an external USB flash drive at up to 500 Hz, subject to channel and source rates. Configure channels, trigger and storage using the USB logging guide. Data Master analyses compatible recordings. An ECU's CAN message list and rate are separate limitations: confirm protocol, baud rate and channel availability.
Documentation discrepancy: ECUMASTER's product page states 800 × 480 pixels; its catalogue states 800 × 600. Verify the resolution for the exact product and revision with ECUMASTER.
Connector and pinout
The standard ADU uses the 35-position AMP automotive connector. The illustration shows the device's rear connector as labelled by the manufacturer. Verify the connector and view before wiring; the 37-position Autosport pinout is different. Source: ECUMASTER standard ADU pinout.
Original wiki drawing of the standard ADU5/ADU7 connector, looking directly at the connector on the rear of the device. Numbering and orientation follow ECUMASTER’s ADU pinout and rear-view diagram; verify the views and markings on each component. Confirm cavity numbers and do not apply this diagram to ADU7 Autosport.
Original wiki signal-group illustration for standard ADU5/ADU7; it is not a physical connector-face drawing. Grouped lines represent separate conductors. Source: ECUMASTER ADU pinout. Refer to the manufacturer drawing for all cavities and orientation.
PinFunction1USB.GND2USB.VBUS3CAN1.H4CAN1.L5CAN2.H6CAN2.L7RS232.RXD8RS232.TXD9Sensor ground10+5V output11Switched 12V12Battery 12V13USB.DM14USB.DP15Analog in A516Analog in A317Analog in A118Frequency/digital in D819Frequency/digital in D620Frequency/digital in D421Frequency/digital in D222Power ground23Ground24Analog in A825Analog in A726Analog in A627Analog in A428Analog in A229Analog output30Frequency/digital in D731Frequency/digital in D532Frequency/digital in D333Frequency/digital in D134Aux 135Aux 2
Wiring and commissioning
The schematic groups separate conductors; consult the full source before making a harness. Battery, switched supply and power ground are pins 12, 11 and 22 respectively; CAN1 high/low are 3/4. USB requires VBUS 2, ground 1, data minus 13 and data plus 14 on the matching receptacle. Sensor inputs, grounds and +5 V output have distinct limits; follow the ADU manual and exact ECU guide. With power isolated, verify cavity numbers and continuity; then configure channels and test a short recording.
Manufacturer overview: ECUMASTER dataloggers and displays. Confirm revision, loom, connector and options before installation.
Rendered revisions
Open each version to inspect formatting, tables and photographs.
Revision 1: ECUMASTER ADU7
The standard ADU7 combines a seven-inch screen and USB data logging. ECUMASTER lists brightness of 1,000 cd/m², weight 732 g and revision-dependent enclosure protection (Rev.2 IP65). The standard connector is not the Autosport connector. ECUMASTER ADU specification.
ECUMASTER ADU7 dash logger. Image: ECUMASTER; reproduced with permission. Manufacturer source.
Specifications and logging
The ADU combines a configurable TFT dashboard, alarms and 15 RGB LEDs with acquisition of vehicle and sensor data. Its inputs include eight 0–5 V analogue channels, eight digital/frequency channels, two low-side outputs, a 0–5 V analogue output, CAN 2.0 A/B and RS232. GPS lap timing requires a suitable external GPS source. The manufacturer’s specification gives an operating range of 6–22 V and 3-axis accelerometer and gyroscope.
Channels can be logged to an external USB flash drive at up to 500 Hz, subject to channel and source rates. Configure channels, trigger and storage using the USB logging guide. Data Master analyses compatible recordings. An ECU's CAN message list and rate are separate limitations: confirm protocol, baud rate and channel availability.
Documentation discrepancy: ECUMASTER's product page states 800 × 480 pixels; its catalogue states 800 × 600. Verify the resolution for the exact product and revision with ECUMASTER.
Connector and pinout
The standard ADU uses the 35-position AMP automotive connector. The illustration shows the device's rear connector as labelled by the manufacturer. Verify the connector and view before wiring; the 37-position Autosport pinout is different. Source: ECUMASTER standard ADU pinout.
Original wiki drawing of the standard ADU5/ADU7 connector, looking directly at the connector on the rear of the device. Numbering and orientation follow ECUMASTER’s ADU pinout and rear-view diagram; verify the views and markings on each component. Confirm cavity numbers and do not apply this diagram to ADU7 Autosport.Original wiki signal-group illustration for standard ADU5/ADU7; it is not a physical connector-face drawing. Grouped lines represent separate conductors. Source: ECUMASTER ADU pinout. Refer to the manufacturer drawing for all cavities and orientation.
Pin
Function
1
USB.GND
2
USB.VBUS
3
CAN1.H
4
CAN1.L
5
CAN2.H
6
CAN2.L
7
RS232.RXD
8
RS232.TXD
9
Sensor ground
10
+5V output
11
Switched 12V
12
Battery 12V
13
USB.DM
14
USB.DP
15
Analog in A5
16
Analog in A3
17
Analog in A1
18
Frequency/digital in D8
19
Frequency/digital in D6
20
Frequency/digital in D4
21
Frequency/digital in D2
22
Power ground
23
Ground
24
Analog in A8
25
Analog in A7
26
Analog in A6
27
Analog in A4
28
Analog in A2
29
Analog output
30
Frequency/digital in D7
31
Frequency/digital in D5
32
Frequency/digital in D3
33
Frequency/digital in D1
34
Aux 1
35
Aux 2
Wiring and commissioning
The schematic groups separate conductors; consult the full source before making a harness. Battery, switched supply and power ground are pins 12, 11 and 22 respectively; CAN1 high/low are 3/4. USB requires VBUS 2, ground 1, data minus 13 and data plus 14 on the matching receptacle. Sensor inputs, grounds and +5 V output have distinct limits; follow the ADU manual and exact ECU guide. With power isolated, verify cavity numbers and continuity; then configure channels and test a short recording.
The standard ADU7 combines a seven-inch screen and USB data logging. ECUMASTER lists brightness of 1,000 cd/m², weight 732 g and revision-dependent enclosure protection (Rev.2 IP65). The standard connector is not the Autosport connector. ECUMASTER ADU specification.
ECUMASTER ADU7 dash logger. Image: ECUMASTER; reproduced with permission. Manufacturer source.
Data analysis software
Data Master 2024.4 analysis showing channel traces, scatter plot and tables. Image: ECUMASTER, reproduced with permission; manufacturer release announcement.
Record the configured channels to the ADU's USB drive, then open the file in ECUMASTER Data Master to compare laps, graph channels and analyse logged data. Video synchronisation requires a suitable recording. Download Data Master and the manual; ADU USB logging instructions. Configure the ADU using its separate ADU software package. Available channels depend on the configured logger, sensors and ECU data.
The ADU combines a configurable TFT dashboard, alarms and 15 RGB LEDs with acquisition of vehicle and sensor data. Its inputs include eight 0–5 V analogue channels, eight digital/frequency channels, two low-side outputs, a 0–5 V analogue output, CAN 2.0 A/B and RS232. GPS lap timing requires a suitable external GPS source. The manufacturer’s specification gives an operating range of 6–22 V and 3-axis accelerometer and gyroscope.
Channels can be logged to an external USB flash drive at up to 500 Hz, subject to channel and source rates. Configure channels, trigger and storage using the USB logging guide. Data Master analyses compatible recordings. An ECU's CAN message list and rate are separate limitations: confirm protocol, baud rate and channel availability.
Documentation discrepancy: ECUMASTER's product page states 800 × 480 pixels; its catalogue states 800 × 600. Verify the resolution for the exact product and revision with ECUMASTER.
Connector and pinout
The standard ADU uses the 35-position AMP automotive connector. The illustration shows the device's rear connector as labelled by the manufacturer. Verify the connector and view before wiring; the 37-position Autosport pinout is different. Source: ECUMASTER standard ADU pinout.
Original wiki drawing of the standard ADU5/ADU7 connector, looking directly at the connector on the rear of the device. Numbering and orientation follow ECUMASTER’s ADU pinout and rear-view diagram; verify the views and markings on each component. Confirm cavity numbers and do not apply this diagram to ADU7 Autosport.Original wiki signal-group illustration for standard ADU5/ADU7; it is not a physical connector-face drawing. Grouped lines represent separate conductors. Source: ECUMASTER ADU pinout. Refer to the manufacturer drawing for all cavities and orientation.
Pin
Function
1
USB.GND
2
USB.VBUS
3
CAN1.H
4
CAN1.L
5
CAN2.H
6
CAN2.L
7
RS232.RXD
8
RS232.TXD
9
Sensor ground
10
+5V output
11
Switched 12V
12
Battery 12V
13
USB.DM
14
USB.DP
15
Analog in A5
16
Analog in A3
17
Analog in A1
18
Frequency/digital in D8
19
Frequency/digital in D6
20
Frequency/digital in D4
21
Frequency/digital in D2
22
Power ground
23
Ground
24
Analog in A8
25
Analog in A7
26
Analog in A6
27
Analog in A4
28
Analog in A2
29
Analog output
30
Frequency/digital in D7
31
Frequency/digital in D5
32
Frequency/digital in D3
33
Frequency/digital in D1
34
Aux 1
35
Aux 2
Wiring and commissioning
The schematic groups separate conductors; consult the full source before making a harness. Battery, switched supply and power ground are pins 12, 11 and 22 respectively; CAN1 high/low are 3/4. USB requires VBUS 2, ground 1, data minus 13 and data plus 14 on the matching receptacle. Sensor inputs, grounds and +5 V output have distinct limits; follow the ADU manual and exact ECU guide. With power isolated, verify cavity numbers and continuity; then configure channels and test a short recording.