Tuning Wiki

This is a historical revision. Read the current page or return to its history.

Page organisation in this revision
Page type
Technical article
Subject
Manifold pressure
Parent
Section level
Applies to
No ECU-specific applicability
Tool groups
None
Manufacturers
Bosch

A sensitivity and an offset

The Motorsport air sensors are the same kind of absolute, piezoresistive element as the production parts, sold with the calibration printed as a sensitivity and an offset at a 5 V supply. The output is ratiometric, so a supply other than 5.00 V scales the result by US / 5.00. Pressure in the equations below is in bar absolute. Boost above the atmosphere is not the number in the equation.

UA = sensitivity × p + offset

Several of these ranges are the production lines under a different order number. The 0.1 to 1.15 bar part is the 10 to 115 kPa line, the 0.2 to 2.5 bar part is the 20 to 250 kPa line, and the 0.2 to 3 bar part is the 20 to 300 kPa line. Those production part numbers and the longer list of housings are on Bosch absolute-pressure sensors. The 0.4 to 4 bar part is not one of those two production lines: its ends are 0.386 V and 4.50 V, not 0.50 V and 4.50 V.

Air sensors, pressure only

SensorOrder numberRangeSensitivityOffsetAt 5 V
PS-AA0 261 230 2160.1 to 1.15 bar4.048 V/bar−4.8 mV0.40 V to 4.65 V
PS-AA0 261 230 2840.2 to 2.5 bar1.848 V/bar+30.4 mV0.40 V to 4.65 V
PS-AS0 281 002 9960.2 to 3 bar1.518 V/bar+96 mV0.40 V to 4.65 V
PSPB 261 209 690-010.2 to 3 bar1.518 V/bar+96 mVclamps 0.3 V to 4.8 V
PS-AL0 261 230 4410.4 to 4 bar1.14286 V/bar−71.43 mV0.386 V to 4.50 V
PSA-NF 02U V0U 197-020.1 to 1.15 bar4.04162 V/bar−4.16 mVnot a 5 V ratio
PSB-4B 261 209 348-010.5 to 4 barsheet, per sensorsheet, per sensorclamps 0.3 V to 4.8 V

The catalogue’s nominal for PSB-4 is 1.143 V/bar and −71 mV, and it says an individual calibration sheet is delivered with each sensor. Use the sheet. The 6 mm tube connector on that part has no function. PSA-N is the odd supply: the specification table is 11 to 16 V, while the feature line says 11 to 14 V, and the output is an absolute voltage with limits of 0.3 to 4.7 V rather than a fraction of a 5 V reference. Its characteristic still comes out at 0.400 V at 0.1 bar.

Tolerance on the 5 V parts, over the compensated range, is ±0.016 bar on the 0.1 to 1.15 bar PS-AA, ±0.034 bar on the 0.2 to 2.5 bar PS-AA, ±0.030 bar on PS-AS, and ±0.042 bar on PSP. PS-AL prints two figures, ±0.035 bar and ±0.050 bar. PSB-4 prints ±0.056 bar on top of the individual sheet. Maximum pressure is 5 bar on the sensors whose range ends at 3 bar or below, and 6 bar on PS-AL. Response is 1 ms on PS-AA, PS-AL and PS-AS, and 0.2 ms on PSP and PSB-4. Supply for the ratiometric parts is 4.75 to 5.25 V on PS-AA, PS-AL and PS-AS, and 4.5 to 5.5 V on PSP and PSB-4. The absolute maximum is 16 V. Current is 9 mA.

Nominal voltage at a 5.00 V supply. A blank cell is outside the range. PSP shares the PS-AS column and then relies on its own sheet only in the sense that the catalogue prints the same sensitivity; its clamps are wider.

bar0.1–1.150.2–2.50.2–30.4–4
0.100.400
0.200.8050.4000.400
0.401.6140.7700.7040.386
1.004.0431.8781.6141.071
1.502.8022.3731.643
2.003.7263.1322.214
2.504.6503.8912.786
3.004.6503.357
4.004.500

At 1.00 bar, about sea-level atmosphere, the 1.15 bar sensor is at 4.04 V and the 3 bar sensor is at 1.61 V. Those are the same voltages as the production 10 to 115 kPa and 20 to 300 kPa columns.

Pins are not common

SensorPlugPin 1Pin 2Pin 3Pin 4
PS-AA, PS-ASMating D 261 205 366-01SupplyGroundSignal
PS-ALMating F 02U B00 555-01SignalGroundSupply
PSA-N, PSB-4Mating F 02U 000 228-01SupplyGroundSignalunused
PSPMating F 02U 000 228-01unusedGroundSignalSupply

PS-AL reverses signal and supply relative to PS-AA. PSP puts the supply on pin 4. The catalogue’s own warning on a wrong pin is a maximum of 5 minutes at 0.3 A. The O-ring grease it names is engine oil, 5W-40, not a silicone grease. The pressure fitting points downwards, within 60° of vertical, so condensate does not sit on the element.

Combined pressure and temperature

PST 1, PST 3 and PST 4 add an NTC on pin 2. The pressure element is still ratiometric. The temperature element is a resistance, and it is not a fraction of the 5 V supply.

PST 1PST 3PST 4
Order number0 261 230 3330 261 230 2800 261 230 423
Pressure0.1 to 1.15 bar0.2 to 3 bar0.4 to 4 bar
Sensitivity4.048 V/bar1.518 V/bar1.143 V/bar
Offset−4.76 mV+96.43 mV−71.43 mV
At 5 V0.40 V to 4.65 V0.40 V to 4.65 V0.386 V to 4.5 V
Tolerance±0.016 bar±0.030 bar0.042 bar
Maximum pressure5 bar5 bar6 bar
Temperature−40 to +130 °C−40 to +130 °C−40 to +130 °C
Supply4.75 to 5.25 V4.75 to 5.25 V4.75 to 5.25 V
Current9 mA9 mA12 mA
Response1 ms1 ms1 ms
Weight24 g24 g22 g

PST 1 and PST 3 use the voltage table above, the 0.1 to 1.15 bar column and the 0.2 to 3 bar column. PST 4 follows the 0.4 to 4 bar column within 1 mV. The PST 1 offset is printed as −4.76 mV and the PS-AA offset as −4.8 mV. At 0.1 bar both give 0.400 V. The cover line of the PST 1 and PST 3 sheet also mentions −40 to 150 °C or −40 to 140 °C. The specification table, and the resistance table, stop at 130 °C. Use 130 °C.

All three use the Bosch Compact plug, mating connector D 261 205 360-01. Pin 1 is ground, pin 2 is the temperature signal, pin 3 is the supply, pin 4 is the pressure signal. That is the same order as the production four-pin sensors. It is not the order of PS-AL or PSP. Fitting diameter is 12.05 mm ± 0.8 mm, the O-ring is 7.59 × 2.62 mm, and the fastener is M6. PST 4 adds a washer. Compensated range is 10 to 85 °C. Maximum supply is 16 V.

Nominal NTC resistance. At 20 °C it is 2.499 kΩ, which is the 2.5 kΩ nominal of the production sensors.

°CResistance°CResistance
−4045.303 kΩ401.174 kΩ
−3026.108 kΩ50833.8 Ω
−2015.458 kΩ60595.4 Ω
−109.395 kΩ70435.6 Ω
05.895 kΩ80322.5 Ω
103.791 kΩ90243.1 Ω
202.499 kΩ100186.6 Ω
252.056 kΩ110144.2 Ω
301.706 kΩ120112.7 Ω
13089.28 Ω

A PST-F in the same catalogue measures fluid, from 10 bar up to a 350 bar version. The plug can look similar. The range does not. It is not an air-box sensor and it is not a manifold sensor.