A sensitivity and an offset
The Motorsport air sensors are the same kind of absolute, piezoresistive element as the production parts, sold with the calibration printed as a sensitivity and an offset at a 5 V supply. The output is ratiometric, so a supply other than 5.00 V scales the result by US / 5.00. Pressure in the equations below is in bar absolute. Boost above the atmosphere is not the number in the equation.
UA = sensitivity × p + offset
Several of these ranges are the production lines under a different order number. The 0.1 to 1.15 bar part is the 10 to 115 kPa line, the 0.2 to 2.5 bar part is the 20 to 250 kPa line, and the 0.2 to 3 bar part is the 20 to 300 kPa line. Those production part numbers and the longer list of housings are on Bosch absolute-pressure sensors. The 0.4 to 4 bar part is not one of those two production lines: its ends are 0.386 V and 4.50 V, not 0.50 V and 4.50 V.
Air sensors, pressure only
| Sensor | Order number | Range | Sensitivity | Offset | At 5 V |
|---|---|---|---|---|---|
| PS-AA | 0 261 230 216 | 0.1 to 1.15 bar | 4.048 V/bar | −4.8 mV | 0.40 V to 4.65 V |
| PS-AA | 0 261 230 284 | 0.2 to 2.5 bar | 1.848 V/bar | +30.4 mV | 0.40 V to 4.65 V |
| PS-AS | 0 281 002 996 | 0.2 to 3 bar | 1.518 V/bar | +96 mV | 0.40 V to 4.65 V |
| PSP | B 261 209 690-01 | 0.2 to 3 bar | 1.518 V/bar | +96 mV | clamps 0.3 V to 4.8 V |
| PS-AL | 0 261 230 441 | 0.4 to 4 bar | 1.14286 V/bar | −71.43 mV | 0.386 V to 4.50 V |
| PSA-N | F 02U V0U 197-02 | 0.1 to 1.15 bar | 4.04162 V/bar | −4.16 mV | not a 5 V ratio |
| PSB-4 | B 261 209 348-01 | 0.5 to 4 bar | sheet, per sensor | sheet, per sensor | clamps 0.3 V to 4.8 V |
The catalogue’s nominal for PSB-4 is 1.143 V/bar and −71 mV, and it says an individual calibration sheet is delivered with each sensor. Use the sheet. The 6 mm tube connector on that part has no function. PSA-N is the odd supply: the specification table is 11 to 16 V, while the feature line says 11 to 14 V, and the output is an absolute voltage with limits of 0.3 to 4.7 V rather than a fraction of a 5 V reference. Its characteristic still comes out at 0.400 V at 0.1 bar.
Tolerance on the 5 V parts, over the compensated range, is ±0.016 bar on the 0.1 to 1.15 bar PS-AA, ±0.034 bar on the 0.2 to 2.5 bar PS-AA, ±0.030 bar on PS-AS, and ±0.042 bar on PSP. PS-AL prints two figures, ±0.035 bar and ±0.050 bar. PSB-4 prints ±0.056 bar on top of the individual sheet. Maximum pressure is 5 bar on the sensors whose range ends at 3 bar or below, and 6 bar on PS-AL. Response is 1 ms on PS-AA, PS-AL and PS-AS, and 0.2 ms on PSP and PSB-4. Supply for the ratiometric parts is 4.75 to 5.25 V on PS-AA, PS-AL and PS-AS, and 4.5 to 5.5 V on PSP and PSB-4. The absolute maximum is 16 V. Current is 9 mA.
Nominal voltage at a 5.00 V supply. A blank cell is outside the range. PSP shares the PS-AS column and then relies on its own sheet only in the sense that the catalogue prints the same sensitivity; its clamps are wider.
| bar | 0.1–1.15 | 0.2–2.5 | 0.2–3 | 0.4–4 |
|---|---|---|---|---|
| 0.10 | 0.400 | |||
| 0.20 | 0.805 | 0.400 | 0.400 | |
| 0.40 | 1.614 | 0.770 | 0.704 | 0.386 |
| 1.00 | 4.043 | 1.878 | 1.614 | 1.071 |
| 1.50 | 2.802 | 2.373 | 1.643 | |
| 2.00 | 3.726 | 3.132 | 2.214 | |
| 2.50 | 4.650 | 3.891 | 2.786 | |
| 3.00 | 4.650 | 3.357 | ||
| 4.00 | 4.500 |
At 1.00 bar, about sea-level atmosphere, the 1.15 bar sensor is at 4.04 V and the 3 bar sensor is at 1.61 V. Those are the same voltages as the production 10 to 115 kPa and 20 to 300 kPa columns.
Pins are not common
| Sensor | Plug | Pin 1 | Pin 2 | Pin 3 | Pin 4 |
|---|---|---|---|---|---|
| PS-AA, PS-AS | Mating D 261 205 366-01 | Supply | Ground | Signal | |
| PS-AL | Mating F 02U B00 555-01 | Signal | Ground | Supply | |
| PSA-N, PSB-4 | Mating F 02U 000 228-01 | Supply | Ground | Signal | unused |
| PSP | Mating F 02U 000 228-01 | unused | Ground | Signal | Supply |
PS-AL reverses signal and supply relative to PS-AA. PSP puts the supply on pin 4. The catalogue’s own warning on a wrong pin is a maximum of 5 minutes at 0.3 A. The O-ring grease it names is engine oil, 5W-40, not a silicone grease. The pressure fitting points downwards, within 60° of vertical, so condensate does not sit on the element.
Combined pressure and temperature
PST 1, PST 3 and PST 4 add an NTC on pin 2. The pressure element is still ratiometric. The temperature element is a resistance, and it is not a fraction of the 5 V supply.
| PST 1 | PST 3 | PST 4 | |
|---|---|---|---|
| Order number | 0 261 230 333 | 0 261 230 280 | 0 261 230 423 |
| Pressure | 0.1 to 1.15 bar | 0.2 to 3 bar | 0.4 to 4 bar |
| Sensitivity | 4.048 V/bar | 1.518 V/bar | 1.143 V/bar |
| Offset | −4.76 mV | +96.43 mV | −71.43 mV |
| At 5 V | 0.40 V to 4.65 V | 0.40 V to 4.65 V | 0.386 V to 4.5 V |
| Tolerance | ±0.016 bar | ±0.030 bar | 0.042 bar |
| Maximum pressure | 5 bar | 5 bar | 6 bar |
| Temperature | −40 to +130 °C | −40 to +130 °C | −40 to +130 °C |
| Supply | 4.75 to 5.25 V | 4.75 to 5.25 V | 4.75 to 5.25 V |
| Current | 9 mA | 9 mA | 12 mA |
| Response | 1 ms | 1 ms | 1 ms |
| Weight | 24 g | 24 g | 22 g |
PST 1 and PST 3 use the voltage table above, the 0.1 to 1.15 bar column and the 0.2 to 3 bar column. PST 4 follows the 0.4 to 4 bar column within 1 mV. The PST 1 offset is printed as −4.76 mV and the PS-AA offset as −4.8 mV. At 0.1 bar both give 0.400 V. The cover line of the PST 1 and PST 3 sheet also mentions −40 to 150 °C or −40 to 140 °C. The specification table, and the resistance table, stop at 130 °C. Use 130 °C.
All three use the Bosch Compact plug, mating connector D 261 205 360-01. Pin 1 is ground, pin 2 is the temperature signal, pin 3 is the supply, pin 4 is the pressure signal. That is the same order as the production four-pin sensors. It is not the order of PS-AL or PSP. Fitting diameter is 12.05 mm ± 0.8 mm, the O-ring is 7.59 × 2.62 mm, and the fastener is M6. PST 4 adds a washer. Compensated range is 10 to 85 °C. Maximum supply is 16 V.
Nominal NTC resistance. At 20 °C it is 2.499 kΩ, which is the 2.5 kΩ nominal of the production sensors.
| °C | Resistance | °C | Resistance |
|---|---|---|---|
| −40 | 45.303 kΩ | 40 | 1.174 kΩ |
| −30 | 26.108 kΩ | 50 | 833.8 Ω |
| −20 | 15.458 kΩ | 60 | 595.4 Ω |
| −10 | 9.395 kΩ | 70 | 435.6 Ω |
| 0 | 5.895 kΩ | 80 | 322.5 Ω |
| 10 | 3.791 kΩ | 90 | 243.1 Ω |
| 20 | 2.499 kΩ | 100 | 186.6 Ω |
| 25 | 2.056 kΩ | 110 | 144.2 Ω |
| 30 | 1.706 kΩ | 120 | 112.7 Ω |
| 130 | 89.28 Ω |
A PST-F in the same catalogue measures fluid, from 10 bar up to a 350 bar version. The plug can look similar. The range does not. It is not an air-box sensor and it is not a manifold sensor.