Absolute, and ratiometric
Bosch’s manifold and boost sensors in this catalogue measure absolute pressure in a gas. A thick-film or a silicon diaphragm sits over a sealed reference, a bridge converts the strain to a voltage, and a circuit on the same substrate compensates the temperature and sets the curve. The output UA is ratiometric. It is a fraction of the supply UV, so a supply that is not 5.00 V scales every figure below by UV / 5.00.
The part number selects the pressure ends. The catalogue then calls the shape of the line characteristic 1 or characteristic 2, and those two numbers do not mean the same thing in the thick-film section and the micromechanical section. Read the ends. One line runs from 0.40 V at the bottom of the range to 4.65 V at the top, at a 5.00 V supply. The other runs from 0.50 V to 4.50 V. A sensor can be electrically healthy on either line and still report the wrong pressure to a control unit that has the other one stored.
The overview of how that pressure is used is on manifold and boost pressure sensors. The motorsport parts, which are printed as a sensitivity in V/bar, are on Bosch Motorsport air-pressure sensors.
The two lines
At UV = 5.00 V the 0.40 to 4.65 V line is
UA = 0.40 V + 4.25 V × (p − p1) / (p2 − p1)
and the 0.50 to 4.50 V line is
UA = 0.50 V + 4.00 V × (p − p1) / (p2 − p1)
p1 and p2 are the ends of that part’s range, in kPa. The thick-film catalogue prints the first line as an equation for two parts. For 0 261 230 004, 20 to 105 kPa, UA = UV × (0.01 × p − 0.12) with p in kPa. For 0 281 002 119, 20 to 250 kPa, UA = UV × (0.85 × p / 230 kPa + 0.0061). Both land on 0.40 V and 4.65 V. The second constant is the rounded form of the straight line. At 100 kPa and 5.00 V it gives 1.878 V, the same figure as the line.
The micromechanical catalogue draws characteristic 1 as the 0.40 to 4.65 V line and characteristic 2 as the 0.50 to 4.50 V line. The moulded-cable part 0 281 002 257, 50 to 400 kPa, prints UA = UV × (p / 437.5 kPa − 1/70), which is the 0.50 to 4.50 V line for that span. The thick-film part 0 281 002 119 is labelled characteristic 2 in its own section and still follows the 0.40 to 4.65 V line. Use the line, not the digit 2, when the two sections are open together.
A blank cell in the table is outside that part’s range. The figures are the nominal line at 5.00 V, before the tolerance band.
| kPa | 20–105 | 10–115 | 20–115 | 20–250 | 20–300 | 50–350 | 50–400 |
|---|---|---|---|---|---|---|---|
| Line | 0.40–4.65 | 0.40–4.65 | 0.40–4.65 | 0.40–4.65 | 0.40–4.65 | 0.50–4.50 | 0.50–4.50 |
| 10 | 0.400 | ||||||
| 20 | 0.400 | 0.805 | 0.400 | 0.400 | 0.400 | ||
| 50 | 1.900 | 2.019 | 1.742 | 0.954 | 0.855 | 0.500 | 0.500 |
| 100 | 4.400 | 4.043 | 3.979 | 1.878 | 1.614 | 1.167 | 1.071 |
| 105 | 4.650 | 4.245 | 4.203 | 1.971 | 1.690 | 1.233 | 1.129 |
| 115 | 4.650 | 4.650 | 2.155 | 1.842 | 1.367 | 1.243 | |
| 200 | 3.726 | 3.132 | 2.500 | 2.214 | |||
| 250 | 4.650 | 3.891 | 3.167 | 2.786 | |||
| 300 | 4.650 | 3.833 | 3.357 | ||||
| 350 | 4.500 | 3.929 | |||||
| 400 | 4.500 |
At a true 100 kPa, which is about sea-level atmosphere, the 20 to 105 kPa part is at 4.40 V and the 20 to 300 kPa part is at 1.61 V. Key-on, engine stopped, tells them apart. The 15 to 380 kPa parts use the 0.50 to 4.50 V line across that wider span, so 100 kPa is 1.43 V. The 50 to 600 kPa parts on the same line read 0.86 V at 100 kPa and 4.50 V at 600 kPa.
The output is clamped inside a fault window. On the micromechanical parts, at a 5 V supply, the lower clamp is 0.25 to 0.35 V and the upper clamp is 4.75 to 4.85 V. A hard 0 V or a hard 5 V is outside the characteristic and is the region the control unit uses to see an open wire or a short. A voltage that is legal for the wrong range does not land in that region.
Thick-film sensors
The measuring element is a ceramic bubble with a trapped reference of about 20 kPa. Piezoresistive thick-film gauges are printed on it, under glass. The gauge factor is about 12. The hybrid on the same substrate amplifies and compensates from −40 °C. Supply is 4.75 to 5.25 V, and must not be taken above 16 V. Input current is under 10 mA. Load impedance is above 50 kΩ. The pressure signal settles in 10 ms or less, which is the slow end of this family. The stated tolerance applies from 10 to 85 °C and is multiplied outside that.
| 0 261 230 004 | 0 281 002 119 | |
|---|---|---|
| Catalogue curve | 1 | 2 |
| Line at 5.00 V | 0.40 to 4.65 V | 0.40 to 4.65 V |
| Range | 20 to 105 kPa | 20 to 250 kPa |
| Max pressure, 1 s at 30 °C | 600 kPa | 500 kPa |
| Temperature | −40 to +125 °C | −40 to +120 °C |
| Sealing | IP 54 A |
Both use connector 1 237 000 039. Terminal 1 is +UV, terminal 2 is ground, terminal 3 is UA. The pressure port points downwards so condensate does not run into the cell. The angle from vertical is +20° to −85°, preferably 0°. The suggested fastener is an M6 screw with a spring washer, and the housing is not to be clamped outside the contact area.
Micromechanical sensors
The element is a silicon diaphragm. Pressure is applied to the top face. A reference vacuum is enclosed between the back of the die and a glass base. A coating is what makes the pressure element, and the temperature element where it is fitted, tolerant of the fuel and oil vapour in a manifold. The sensor is built to be mounted on a horizontal face of the manifold, pressure fitting downwards, sealed by O-rings, so condensate does not collect on the die.
Supply is 4.5 to 5.5 V, typically 5.0 V, and the absolute maximum is 16 V. Current at 5 V is 6.0 to 12.5 mA, typically 9.0 mA. The 10 % to 90 % response is typically 1.0 ms. Operating temperature is −40 to +130 °C. Where an NTC is fitted, its nominal resistance at +20 °C is 2.5 kΩ ± 5 %, the measuring current is not to exceed 1 mA, and the catalogue’s circuit uses a 1 kΩ series resistor. The thermal time constant is 10 s or less in air moving at 6 m/s. The resistance table for a motorsport sensor of that same nominal is on the Motorsport page. This catalogue does not repeat that table for the production NTC.
| Part | Range, kPa | Catalogue curve | Line | Temperature |
|---|---|---|---|---|
| B 261 260 136 | 10 to 115 | 1 | 0.40–4.65 | No |
| 0 261 230 052 | 10 to 115 | 1 | 0.40–4.65 | No |
| 0 281 002 487 | 20 to 250 | 1 | 0.40–4.65 | No |
| 0 261 230 030 | 10 to 115 | 1 | 0.40–4.65 | Yes |
| 0 261 230 042 | 20 to 250 | 1 | 0.40–4.65 | Yes |
| 0 281 002 437 | 20 to 300 | 1 | 0.40–4.65 | Yes |
| 0 281 002 456 | 50 to 350 | 2 | 0.50–4.50 | Yes |
| B 261 260 508 | 50 to 400 | 2 | 0.50–4.50 | Yes |
B 261 260 136 and B 261 260 508 are the provisional numbers printed in the catalogue, with a note that the order number was to follow. Without a temperature element the plug housing is 1 928 403 966 and the pins are 1 supply, 2 ground, 3 signal. With a temperature element the plug housing is 1 928 403 736, the contact is 1 928 498 060, the individual gasket is 1 928 300 599, and the pins are 1 ground, 2 NTC, 3 supply, 4 signal. A three-pin part needs three contacts and three gaskets. A four-pin part needs four of each. The accessories are ordered separately.
0 281 006 076, trade name DS-S3-TF, is the later sensor named as the successor of 0 281 002 437. Its own sheet gives 20 to 300 kPa, supply 4.75 to 5.25 V, response 1 ms, operating temperature −40 to +130 °C, and the same 2.5 kΩ ± 5 % NTC at +20 °C. The pins are unchanged: 1 ground, 2 NTC, 3 supply, 4 signal. The plug housing is again 1 928 403 736. Contacts are 1 928 498 056 for 0.5 to 1.0 mm² and 1 928 498 057 for 1.5 to 2.5 mm², with seals 1 928 300 599 and 1 928 300 600, and dummy plug 1 928 300 601. That sheet does not repeat the characteristic equation. The predecessor is the 0.40 to 4.65 V line. Confirm the successor against its own curve before treating the two numbers as one calibration.
Moulded cable, media-resistant housings, and cells
0 281 002 257 is the moulded-cable sensor for boost pressure on a turbocharged diesel, used for boost control and smoke limiting. The range is 50 to 400 kPa, with the tighter tolerance from 70 to 360 kPa. It survives 600 kPa. Ambient temperature is −40 to +120 °C, with a short allowance to 140 °C. Supply is 5 V ± 10 %. Current is 12 mA or less. Response is 5 ms or less. On the 350 kPa span the as-new error from 70 to 360 kPa is ±1.0 %, and ±1.2 % after the endurance test. Outside that pressure band the as-new figure is ±1.8 %, and ±2.0 % after endurance. Those percentages apply from +20 to +110 °C. The multiplier is 1.0 inside that band, rising to 3.0 at −40 °C, 1.6 at +120 °C and 2.0 at +140 °C. The metal bushes are tightened to 10 Nm or less, and the fitting points downwards, within 60° of vertical.
The pin order on 0 281 002 257 is not the thick-film order. Pin 1 is the signal, pin 2 is +5 V, pin 3 is ground.
A second micromechanical family is sealed for fuel and oil, and is the one the catalogue names for absolute manifold pressure in that environment. Supply, current, clamps and the 2.5 kΩ NTC match the family above. Response is faster: typically 0.2 ms. The temperature time constant of the NTC, where fitted, is 45 s or less at 6 m/s.
| Part | Range, kPa | Catalogue curve | Line | Form |
|---|---|---|---|---|
| 0 261 230 020 | 20 to 115 | 1 | 0.40–4.65 | Housing, no temperature |
| 0 281 002 137 | 20 to 250 | 1 | 0.40–4.65 | Housing, no temperature |
| 0 261 230 022 | 10 to 115 | 1 | 0.40–4.65 | Housing, NTC |
| 0 261 230 013 | 20 to 115 | 1 | 0.40–4.65 | Housing, NTC |
| 0 281 002 205 | 20 to 250 | 1 | 0.40–4.65 | Housing, NTC |
| 0 281 002 244 | 50 to 350 | 2 | 0.50–4.50 | Housing, NTC |
| 0 281 002 316 | 50 to 400 | 2 | 0.50–4.50 | Housing, NTC |
| 0 281 002 420 | 50 to 600 | 2 | 0.50–4.50 | Housing, NTC |
| 0 261 230 009 | 10 to 115 | 1 | 0.40–4.65 | Hose connection |
| 1 267 030 835 | 15 to 380 | 2 | 0.50–4.50 | Clip module, with cable |
Pins that the catalogue prints next to the part:
- 0 261 230 009, 0 261 230 020 and 0 281 002 137: pin 1 supply, pin 2 ground, pin 3 signal.
- 0 261 230 013, 0 261 230 022, 0 281 002 205 and 0 281 002 244: pin 1 ground, pin 2 NTC, pin 3 supply, pin 4 signal.
- 1 267 030 835: pin 1 ground, pin 2 supply, pin 3 vacant, pin 4 signal.
0 281 002 316 and 0 281 002 420 are in the range table as temperature-sensor housings. Copy the four-pin order onto them only from the drawing that carries that part number.
The cells in a transistor-style can are for building into a device, including a control unit. Pressure range and curve are the calibration. The catalogue’s pin numbers on that can are pin 6 signal, pin 7 ground, pin 8 supply.
| Cell | Range, kPa | Catalogue curve | Line |
|---|---|---|---|
| 0 273 300 001 | 20 to 105 | 1 | 0.40–4.65 |
| 0 273 300 006 | 10 to 115 | 1 | 0.40–4.65 |
| 0 273 300 002 | 20 to 115 | 1 | 0.40–4.65 |
| 0 273 300 004 | 20 to 250 | 1 | 0.40–4.65 |
| 0 273 300 017 | 15 to 380 | 2 | 0.50–4.50 |
| 0 261 230 036 | 15 to 380 | 2 | 0.50–4.50 |
| 0 273 300 010 | 50 to 350 | 2 | 0.50–4.50 |
| 0 273 300 019 | 50 to 400 | 2 | 0.50–4.50 |
| 0 261 230 033 | 50 to 400 | 2 | 0.50–4.50 |
| 0 273 300 012 | 50 to 600 | 2 | 0.50–4.50 |
Plug housings named for the media-resistant parts are 1 928 403 870 for 0 281 002 137, 1 928 403 913 for the temperature-sensor parts that use it, and 1 928 403 736 for 0 281 002 420. A three-pin plug is one housing, three contacts and three gaskets. A four-pin plug is four contacts and four gaskets.