Page organisation in this revision
- Page type
- Technical article
- Subject
- Airflow
- Parent
- Section level
- Applies to
- No ECU-specific applicability
- Tool groups
- None
- Manufacturers
- Bosch
Changes from revision 2 to revision 2
Removed text is struck through; added text is highlighted.
What the HFM 5 measures
The Bosch HFM 5 is a micromechanical hot-film air-mass meter for flows up to about 1000 kg/h. A heated element in a small flow passage gives up heat to the air. More air takes more heat. The temperature difference is the measure of the mass flowing past the element, and a hybrid circuit turns that into a voltage and also detects when the flow reverses during intake pulsation. Only a sample of the air passes the element. The relationship between that sample and the mass in the whole tube is fixed when the meter is calibrated, which is why the sensor and its tube belong together.
The plug-in sensor can sit in an air-filter housing or in a measuring venturi in the intake duct. Venturi size follows the flow the engine needs. Nominal supply is 14 V, and the meter runs from 8 to 17 V. The signal UA is 0 to 5 V. Input current is under 0.1 A. Vibration acceleration may reach 150 m/s². After a step from 10 kg/h to 0.7 of nominal flow, the signal reaches 63 % of its final value within 15 ms. After a flow step, the error is within 5 % within 30 ms. The temperature range is −40 to +120 °C, with a short allowance to +130 °C. Relative accuracy is within 3 % of the measured value.
The five housings
0 280 217 1230 280 218 0190 280 217 5310 280 218 0080 281 002 421
Curve12345
Flow, kg/h8 to 37010 to 48012 to 64012 to 85015 to 1000
Fitting length LE, mm2222221622
Fitting length LA, mm2020201620
Installation length L, mm9696130100130
Connection diameter D, mm60708086 / 8492
Venturi inside diameter, mm5062717882
Pressure drop at nominal massunder 20 hPaunder 15 hPaunder 15 hPaunder 15 hPaunder 15 hPa
Temperature sensorYesYesYesNoYes
The 86 / 84 mm diameter on 0 280 218 008 is the inflow end and the outflow end. The voltage table for characteristic 5 is headed 0 280 002 421, while the range table uses 0 281 002 421. Read the number on the housing before using either column. A later listing of 0 281 002 421 gives a measuring range of −50 to 1200 kg/h and includes an ambient-temperature sensor. That wider range is a different calibration from the 15 to 1000 kg/h column above.
The plug-in sensor is a measuring-passage cover, the sensor element, a mounting plate, a hybrid under its own cover, the plug body, an O-ring and, where fitted, the auxiliary temperature sensor.
Output voltage against mass flow
Voltage is UA in volts. A blank cell means that flow is outside the range of that part.
kg/hCurve 1Curve 2Curve 3Curve 4Curve 5
81.48371.2390
101.58191.36441.2695
151.78981.52411.40601.33951.2315
302.27391.87481.71001.62511.4758
602.88682.37102.15632.01091.8310
1203.62552.99982.75222.55642.3074
2504.47273.74943.50703.26552.9212
3704.94064.16953.93933.67173.2874
4804.45784.23493.94903.5461
6404.56694.26003.8432
8504.57274.1499
10004.3312
The same 3 V can be a modest flow on curve 1 and a much larger flow on curve 5. Swapping the insert, or the tube, without the matching calibration makes the control unit see the wrong air mass. The earlier thick-film meter is the HFM 2. A later housing with an integrated deflection bypass is the HFM 7.
Connector
PinFunction
1Additional temperature sensor. Absent on version 4, part 0 280 218 008.
2Supply UV
3Signal ground
45 V reference
5Measurement signal UA
The five-pin plug housing is 1 928 403 836. Contact pins are 1 987 280 103 for 0.5 to 1.0 mm² and 1 987 280 105 for 1.5 to 2.5 mm², with individual gaskets 1 987 280 106 and 1 987 280 107. A later accessory list for the same plug housing gives contact pins 1 928 498 056 and 1 928 498 057, packed 100 at a time, and single-wire seals 1 928 300 599 and 1 928 300 600. Each plug needs one housing, five pins and five seals, crimped with the original AMP tool. The accessories are ordered separately from the sensor.
Intake-air temperature sensor
Where the auxiliary sensor is fitted, its nominal resistance at 25 °C is 2.00 kΩ ± 5 %. Resistance falls as temperature rises.
°CResistance°CResistance
−4039.26 kΩ50835 Ω
−3022.96 kΩ60609 Ω
−2013.85 kΩ70452 Ω
−108.609 kΩ80340 Ω
05.499 kΩ90261 Ω
103.604 kΩ100202 Ω
202.420 kΩ110159 Ω
301.662 kΩ120127 Ω
401.166 kΩ130102 Ω
Pin 1 open, or a temperature reading that does not fall as the air warms, is the temperature sensor. Pin 5 is the mass signal. A dead temperature sensor on a meter that has one does not by itself prove the film is dead, and a film fault does not by itself prove the temperature sensor is dead.
Rendered revisions
Open each version to inspect formatting, tables and photographs.
Revision 2: Bosch HFM 5 hot-film air-mass meter
What the HFM 5 measures
The Bosch HFM 5 is a micromechanical hot-film air-mass meter for flows up to about 1000 kg/h. A heated element in a small flow passage gives up heat to the air. More air takes more heat. The temperature difference is the measure of the mass flowing past the element, and a hybrid circuit turns that into a voltage and also detects when the flow reverses during intake pulsation. Only a sample of the air passes the element. The relationship between that sample and the mass in the whole tube is fixed when the meter is calibrated, which is why the sensor and its tube belong together.
The plug-in sensor can sit in an air-filter housing or in a measuring venturi in the intake duct. Venturi size follows the flow the engine needs. Nominal supply is 14 V, and the meter runs from 8 to 17 V. The signal UA is 0 to 5 V. Input current is under 0.1 A. Vibration acceleration may reach 150 m/s². After a step from 10 kg/h to 0.7 of nominal flow, the signal reaches 63 % of its final value within 15 ms. After a flow step, the error is within 5 % within 30 ms. The temperature range is −40 to +120 °C, with a short allowance to +130 °C. Relative accuracy is within 3 % of the measured value.
The five housings
| 0 280 217 123 | 0 280 218 019 | 0 280 217 531 | 0 280 218 008 | 0 281 002 421 |
| Curve | 1 | 2 | 3 | 4 | 5 |
| Flow, kg/h | 8 to 370 | 10 to 480 | 12 to 640 | 12 to 850 | 15 to 1000 |
| Fitting length LE, mm | 22 | 22 | 22 | 16 | 22 |
| Fitting length LA, mm | 20 | 20 | 20 | 16 | 20 |
| Installation length L, mm | 96 | 96 | 130 | 100 | 130 |
| Connection diameter D, mm | 60 | 70 | 80 | 86 / 84 | 92 |
| Venturi inside diameter, mm | 50 | 62 | 71 | 78 | 82 |
| Pressure drop at nominal mass | under 20 hPa | under 15 hPa | under 15 hPa | under 15 hPa | under 15 hPa |
| Temperature sensor | Yes | Yes | Yes | No | Yes |
The 86 / 84 mm diameter on 0 280 218 008 is the inflow end and the outflow end. The voltage table for characteristic 5 is headed 0 280 002 421, while the range table uses 0 281 002 421. Read the number on the housing before using either column. A later listing of 0 281 002 421 gives a measuring range of −50 to 1200 kg/h and includes an ambient-temperature sensor. That wider range is a different calibration from the 15 to 1000 kg/h column above.
The plug-in sensor is a measuring-passage cover, the sensor element, a mounting plate, a hybrid under its own cover, the plug body, an O-ring and, where fitted, the auxiliary temperature sensor.
Output voltage against mass flow
Voltage is UA in volts. A blank cell means that flow is outside the range of that part.
| kg/h | Curve 1 | Curve 2 | Curve 3 | Curve 4 | Curve 5 |
| 8 | 1.4837 | 1.2390 | | | |
| 10 | 1.5819 | 1.3644 | 1.2695 | | |
| 15 | 1.7898 | 1.5241 | 1.4060 | 1.3395 | 1.2315 |
| 30 | 2.2739 | 1.8748 | 1.7100 | 1.6251 | 1.4758 |
| 60 | 2.8868 | 2.3710 | 2.1563 | 2.0109 | 1.8310 |
| 120 | 3.6255 | 2.9998 | 2.7522 | 2.5564 | 2.3074 |
| 250 | 4.4727 | 3.7494 | 3.5070 | 3.2655 | 2.9212 |
| 370 | 4.9406 | 4.1695 | 3.9393 | 3.6717 | 3.2874 |
| 480 | | 4.4578 | 4.2349 | 3.9490 | 3.5461 |
| 640 | | | 4.5669 | 4.2600 | 3.8432 |
| 850 | | | | 4.5727 | 4.1499 |
| 1000 | | | | | 4.3312 |
The same 3 V can be a modest flow on curve 1 and a much larger flow on curve 5. Swapping the insert, or the tube, without the matching calibration makes the control unit see the wrong air mass. The earlier thick-film meter is the HFM 2. A later housing with an integrated deflection bypass is the HFM 7.
Connector
| Pin | Function |
| 1 | Additional temperature sensor. Absent on version 4, part 0 280 218 008. |
| 2 | Supply UV |
| 3 | Signal ground |
| 4 | 5 V reference |
| 5 | Measurement signal UA |
The five-pin plug housing is 1 928 403 836. Contact pins are 1 987 280 103 for 0.5 to 1.0 mm² and 1 987 280 105 for 1.5 to 2.5 mm², with individual gaskets 1 987 280 106 and 1 987 280 107. A later accessory list for the same plug housing gives contact pins 1 928 498 056 and 1 928 498 057, packed 100 at a time, and single-wire seals 1 928 300 599 and 1 928 300 600. Each plug needs one housing, five pins and five seals, crimped with the original AMP tool. The accessories are ordered separately from the sensor.
Intake-air temperature sensor
Where the auxiliary sensor is fitted, its nominal resistance at 25 °C is 2.00 kΩ ± 5 %. Resistance falls as temperature rises.
| °C | Resistance | °C | Resistance |
| −40 | 39.26 kΩ | 50 | 835 Ω |
| −30 | 22.96 kΩ | 60 | 609 Ω |
| −20 | 13.85 kΩ | 70 | 452 Ω |
| −10 | 8.609 kΩ | 80 | 340 Ω |
| 0 | 5.499 kΩ | 90 | 261 Ω |
| 10 | 3.604 kΩ | 100 | 202 Ω |
| 20 | 2.420 kΩ | 110 | 159 Ω |
| 30 | 1.662 kΩ | 120 | 127 Ω |
| 40 | 1.166 kΩ | 130 | 102 Ω |
Pin 1 open, or a temperature reading that does not fall as the air warms, is the temperature sensor. Pin 5 is the mass signal. A dead temperature sensor on a meter that has one does not by itself prove the film is dead, and a film fault does not by itself prove the temperature sensor is dead.
Revision 2: Bosch HFM 5 hot-film air-mass meter
What the HFM 5 measures
The Bosch HFM 5 is a micromechanical hot-film air-mass meter for flows up to about 1000 kg/h. A heated element in a small flow passage gives up heat to the air. More air takes more heat. The temperature difference is the measure of the mass flowing past the element, and a hybrid circuit turns that into a voltage and also detects when the flow reverses during intake pulsation. Only a sample of the air passes the element. The relationship between that sample and the mass in the whole tube is fixed when the meter is calibrated, which is why the sensor and its tube belong together.
The plug-in sensor can sit in an air-filter housing or in a measuring venturi in the intake duct. Venturi size follows the flow the engine needs. Nominal supply is 14 V, and the meter runs from 8 to 17 V. The signal UA is 0 to 5 V. Input current is under 0.1 A. Vibration acceleration may reach 150 m/s². After a step from 10 kg/h to 0.7 of nominal flow, the signal reaches 63 % of its final value within 15 ms. After a flow step, the error is within 5 % within 30 ms. The temperature range is −40 to +120 °C, with a short allowance to +130 °C. Relative accuracy is within 3 % of the measured value.
The five housings
| 0 280 217 123 | 0 280 218 019 | 0 280 217 531 | 0 280 218 008 | 0 281 002 421 |
| Curve | 1 | 2 | 3 | 4 | 5 |
| Flow, kg/h | 8 to 370 | 10 to 480 | 12 to 640 | 12 to 850 | 15 to 1000 |
| Fitting length LE, mm | 22 | 22 | 22 | 16 | 22 |
| Fitting length LA, mm | 20 | 20 | 20 | 16 | 20 |
| Installation length L, mm | 96 | 96 | 130 | 100 | 130 |
| Connection diameter D, mm | 60 | 70 | 80 | 86 / 84 | 92 |
| Venturi inside diameter, mm | 50 | 62 | 71 | 78 | 82 |
| Pressure drop at nominal mass | under 20 hPa | under 15 hPa | under 15 hPa | under 15 hPa | under 15 hPa |
| Temperature sensor | Yes | Yes | Yes | No | Yes |
The 86 / 84 mm diameter on 0 280 218 008 is the inflow end and the outflow end. The voltage table for characteristic 5 is headed 0 280 002 421, while the range table uses 0 281 002 421. Read the number on the housing before using either column. A later listing of 0 281 002 421 gives a measuring range of −50 to 1200 kg/h and includes an ambient-temperature sensor. That wider range is a different calibration from the 15 to 1000 kg/h column above.
The plug-in sensor is a measuring-passage cover, the sensor element, a mounting plate, a hybrid under its own cover, the plug body, an O-ring and, where fitted, the auxiliary temperature sensor.
Output voltage against mass flow
Voltage is UA in volts. A blank cell means that flow is outside the range of that part.
| kg/h | Curve 1 | Curve 2 | Curve 3 | Curve 4 | Curve 5 |
| 8 | 1.4837 | 1.2390 | | | |
| 10 | 1.5819 | 1.3644 | 1.2695 | | |
| 15 | 1.7898 | 1.5241 | 1.4060 | 1.3395 | 1.2315 |
| 30 | 2.2739 | 1.8748 | 1.7100 | 1.6251 | 1.4758 |
| 60 | 2.8868 | 2.3710 | 2.1563 | 2.0109 | 1.8310 |
| 120 | 3.6255 | 2.9998 | 2.7522 | 2.5564 | 2.3074 |
| 250 | 4.4727 | 3.7494 | 3.5070 | 3.2655 | 2.9212 |
| 370 | 4.9406 | 4.1695 | 3.9393 | 3.6717 | 3.2874 |
| 480 | | 4.4578 | 4.2349 | 3.9490 | 3.5461 |
| 640 | | | 4.5669 | 4.2600 | 3.8432 |
| 850 | | | | 4.5727 | 4.1499 |
| 1000 | | | | | 4.3312 |
The same 3 V can be a modest flow on curve 1 and a much larger flow on curve 5. Swapping the insert, or the tube, without the matching calibration makes the control unit see the wrong air mass. The earlier thick-film meter is the HFM 2. A later housing with an integrated deflection bypass is the HFM 7.
Connector
| Pin | Function |
| 1 | Additional temperature sensor. Absent on version 4, part 0 280 218 008. |
| 2 | Supply UV |
| 3 | Signal ground |
| 4 | 5 V reference |
| 5 | Measurement signal UA |
The five-pin plug housing is 1 928 403 836. Contact pins are 1 987 280 103 for 0.5 to 1.0 mm² and 1 987 280 105 for 1.5 to 2.5 mm², with individual gaskets 1 987 280 106 and 1 987 280 107. A later accessory list for the same plug housing gives contact pins 1 928 498 056 and 1 928 498 057, packed 100 at a time, and single-wire seals 1 928 300 599 and 1 928 300 600. Each plug needs one housing, five pins and five seals, crimped with the original AMP tool. The accessories are ordered separately from the sensor.
Intake-air temperature sensor
Where the auxiliary sensor is fitted, its nominal resistance at 25 °C is 2.00 kΩ ± 5 %. Resistance falls as temperature rises.
| °C | Resistance | °C | Resistance |
| −40 | 39.26 kΩ | 50 | 835 Ω |
| −30 | 22.96 kΩ | 60 | 609 Ω |
| −20 | 13.85 kΩ | 70 | 452 Ω |
| −10 | 8.609 kΩ | 80 | 340 Ω |
| 0 | 5.499 kΩ | 90 | 261 Ω |
| 10 | 3.604 kΩ | 100 | 202 Ω |
| 20 | 2.420 kΩ | 110 | 159 Ω |
| 30 | 1.662 kΩ | 120 | 127 Ω |
| 40 | 1.166 kΩ | 130 | 102 Ω |
Pin 1 open, or a temperature reading that does not fall as the air warms, is the temperature sensor. Pin 5 is the mass signal. A dead temperature sensor on a meter that has one does not by itself prove the film is dead, and a film fault does not by itself prove the temperature sensor is dead.