Simos 2 is a Siemens petrol engine-management family documented on naturally aspirated Volkswagen Group engines. Škoda and Audi training material identifies Simos 2 on the 1.6-litre AEH; a Škoda workshop manual also lists the 1.6 AKL with Simos 2. The precise ECU suffix and software must be identified on the actual unit before selecting a definition or programming method.
Documented examples and identification
Škoda SSP 15 describes the 1.6 AEH with Simos 2, a hot-film air-mass meter and a variable intake manifold in the Octavia. A Škoda Octavia workshop-manual copy lists AEH and AKL as 1,595 cm³, 74 kW naturally aspirated engines with Simos 2. It is a table for those applications, not a complete fitment catalogue or proof of an individual ECU suffix.
VW SSP 191 separately lists Simos 2 on the Passat 1.6 AHL and says that Passat installation has no twin-path intake manifold. Do not assume the Octavia manifold hardware is present because a car has a Simos 2 ECU. Audi SSP 182 also names Simos 2 for its A3 AEH example. These sources identify the family without allocating a suffix to every example.
A Snap-on diagnostic application guide lists selected SEAT Ibiza 1.6 AEH and AKL examples under Simos 2.1; this is the tool supplier's application coverage, not a universal fitment or flashing statement. Record the ECU label, full part and software numbers, engine code and gearbox, then match them to the selected tool's current documentation. A petrol Simos 2.1 is distinct from the later diesel PCR 2.1 label.
A separately reproduced SEAT injection-system technical-data table explicitly pairs AEH and AKL with Simos 2.1, while its APF and AUR column names Simos 3.3. It is a scoped workshop table, not proof of the controller in every vehicle with those engine codes. Its technical figures and service procedures are for the listed installations; identify the ECU before deciding which column and diagnostic procedure apply.
For Volkswagen’s separately documented AHT 1.0 system, see Simos 2P, including its manifold-pressure load sensing and paired port injection. Identify the fitted controller before applying either example.
AEH air and engine control
For its AEH example, Audi SSP 182 lists hot-film air-mass meter G70, engine-speed sender G28, Hall sender G40, lambda sensor G39, knock sensor G61, coolant and intake-air temperature sensors and throttle-control unit J338. It shows four injection valves and two ignition coils. The throttle assembly in that system includes a throttle potentiometer, a positioner potentiometer and an idle switch; verify the actual hardware before applying details to another ECU or vehicle.
On the variable-manifold AEH described by Škoda SSP 19, the ECU operates N156 in response to load and engine speed and uses vacuum to change intake runner length. The long path supports lower-speed torque and the short path the higher-speed range. The programme describes the short path as the fallback when the valve signal is absent. It also describes a separate high-speed changeover used for soft speed limiting in that example: these are factory strategy descriptions, not generic switch points or an instruction to raise a limiter.
Diagnosis and tuning baseline
Record the exact controller and software, fuel, faults, modifications and the complaint. Investigate ignition misfires, intake leaks, air-meter and coolant-temperature plausibility, fuel delivery and lambda operation before changing calibration.
Where supported, compare engine speed, throttle, air mass, lambda, fuel corrections and ignition or knock-related values under repeatable conditions. Confirm units, availability and sample rate for the specific diagnostic tool; a displayed air or torque value may be calculated rather than independently measured.
If the documented variable-manifold engine has a power complaint, the Škoda Octavia workshop procedure checks changeover operation, N156, vacuum lines and linkage. A failed changeover has several possible electrical, vacuum and mechanical causes; follow the current procedure for the actual installation.
Confirm that any calibration definition matches the exact file and that axes, units and functions have been validated. The cited factory descriptions do not provide universal map addresses, performance gains or safe timing changes. A plausible map name is not proof that it controls the intended function.
Octavia 1.6/74 kW changeover test example
The reproduced Škoda workshop manual gives a practical way to investigate a power complaint on its 1.6/74 kW Simos 2 installation. With the engine warm, it describes observing the vacuum actuator and linkage while the engine is briefly accelerated and returned to idle. The linkage is expected to move and return. If it does not, the procedure calls for checking N156 and its actuation, vacuum hoses and connections, and free movement of the changeover mechanism. This brief workshop test does not by itself establish the switching point under road load or identify the failed part. Follow the current procedure and conditions for the vehicle being tested. Škoda intake-manifold changeover test.
In the same manual’s N156 electrical test, the specified resistance across the disconnected valve is 25–35 Ω. It separately checks supply and uses final-control diagnosis to check actuation. A coil within that range does not prove the valve moves, vacuum is available or the linkage works. The stated value and test equipment belong to that workshop example, not every N156 installation; verify the current specification and circuit for the actual engine.
For the Octavia 1.6/74 kW workshop example, see Simos 2 Octavia lambda adaptation and knock log review for scoped measuring-block meanings and interpretation.
Processor and memory
An owner report on a Simos 2 unit with part number 06A906019BQ (Siemens 5WP4441-02) identifies the processor as a Siemens/Infineon SAK-C167CR-LM and the flash as an AMD AM29F200BB, read by bootstrap loader and in-circuit by K-line (single owner report; seen in search summary, as the forum was not directly accessible). A tool vendor's listing separately names Siemens 5WP4 Simos 2.x (2-plug) as a 29F200 flash unit for immobiliser work. Both are single-source, unit-specific statements, not a processor specification for every Simos 2 variant.
Reading and writing
Diagnostic access, reading the calibration, reading all relevant memory and writing a modified file are separate capabilities. The diagnostic supplier's 2.1 vehicle listing does not establish any particular flashing protocol. Check the tool provider's exact ECU and software coverage, memory scope, checksum handling, power supply and recovery procedure before writing; retain a restorable original in the appropriate format. A purchased or supplied original is not automatically the vehicle's current calibration or a complete backup.
For a programming-tool example, the ECU Tools CombiLoader listing includes Siemens SIMOS 2.x in its base software's ST10F27x/C16x bootstrap-loader coverage. The listing does not identify all supported ECU part and software numbers or specify which memory regions are accessible for each 2.x controller. This is a product-specific claim, not proof of OBD read/write support or that its output contains all ECU and immobiliser data. Confirm the exact unit, connection, read/write operation and recovery coverage with the provider and record the memory area and provenance of every read.
Bench connection pinout
Bench-connection pins for this unit are drawn in Simos 2 bench connection pinout.
Sources
Škoda SSP 15: Octavia, AEH engine description. Simos 2 and variable intake. Accessed 17 November 2026.
Škoda SSP 19: 1.6 and 1.8-litre petrol engines, French edition, AEH system overview and N156 description. Accessed 17 November 2026.
Audi SSP 182: A3 engineering, AEH Simos 2 system overview. Accessed 17 November 2026.
Volkswagen SSP 191: Passat 1997, 1.6 AHL engine data. Accessed 17 November 2026.
Škoda Octavia Mk1 1.6/74 kW workshop manual, iFixit-hosted copy, AEH/AKL technical data; intake-manifold changeover test, separately reproduced. Accessed 17 November 2026.
Snap-on European Software Applications Guide. Product-specific Simos 2.1 diagnostic coverage. Accessed 17 November 2026.
Nefarious Motorsports: VAG Simos2 ECU bench read/write with Galetto/Minimon. Owner report: processor and flash on a 5WP4441-02 unit; seen in search summary, direct access returned HTTP 403. Accessed 19 November 2026.
IMMO Decoding GUIDE, tool vendor list. Siemens 5WP4 Simos 2.x (2 plug) flash 29F200 entry; seen in search summary. Accessed 19 November 2026.
Open each version to inspect formatting, tables and photographs.
Revision 7: Simos 2
Simos 2 is a Siemens petrol engine-management family documented on naturally aspirated Volkswagen Group engines. Škoda and Audi training material identifies Simos 2 on the 1.6-litre AEH; a Škoda workshop manual also lists the 1.6 AKL with Simos 2. The precise ECU suffix and software must be identified on the actual unit before selecting a definition or programming method.
Documented examples and identification
Škoda SSP 15 describes the 1.6 AEH with Simos 2, a hot-film air-mass meter and a variable intake manifold in the Octavia. A Škoda Octavia workshop-manual copy lists AEH and AKL as 1,595 cm³, 74 kW naturally aspirated engines with Simos 2. It is a table for those applications, not a complete fitment catalogue or proof of an individual ECU suffix.
VW SSP 191 separately lists Simos 2 on the Passat 1.6 AHL and says that Passat installation has no twin-path intake manifold. Do not assume the Octavia manifold hardware is present because a car has a Simos 2 ECU. Audi SSP 182 also names Simos 2 for its A3 AEH example. These sources identify the family without allocating a suffix to every example.
A Snap-on diagnostic application guide lists selected SEAT Ibiza 1.6 AEH and AKL examples under Simos 2.1; this is the tool supplier's application coverage, not a universal fitment or flashing statement. Record the ECU label, full part and software numbers, engine code and gearbox, then match them to the selected tool's current documentation. A petrol Simos 2.1 is distinct from the later diesel PCR 2.1 label.
A separately reproduced SEAT injection-system technical-data table explicitly pairs AEH and AKL with Simos 2.1, while its APF and AUR column names Simos 3.3. It is a scoped workshop table, not proof of the controller in every vehicle with those engine codes. Its technical figures and service procedures are for the listed installations; identify the ECU before deciding which column and diagnostic procedure apply.
For Volkswagen’s separately documented AHT 1.0 system, see Simos 2P, including its manifold-pressure load sensing and paired port injection. Identify the fitted controller before applying either example.
AEH air and engine control
For its AEH example, Audi SSP 182 lists hot-film air-mass meter G70, engine-speed sender G28, Hall sender G40, lambda sensor G39, knock sensor G61, coolant and intake-air temperature sensors and throttle-control unit J338. It shows four injection valves and two ignition coils. The throttle assembly in that system includes a throttle potentiometer, a positioner potentiometer and an idle switch; verify the actual hardware before applying details to another ECU or vehicle.
On the variable-manifold AEH described by Škoda SSP 19, the ECU operates N156 in response to load and engine speed and uses vacuum to change intake runner length. The long path supports lower-speed torque and the short path the higher-speed range. The programme describes the short path as the fallback when the valve signal is absent. It also describes a separate high-speed changeover used for soft speed limiting in that example: these are factory strategy descriptions, not generic switch points or an instruction to raise a limiter.
Diagnosis and tuning baseline
- Record the exact controller and software, fuel, faults, modifications and the complaint. Investigate ignition misfires, intake leaks, air-meter and coolant-temperature plausibility, fuel delivery and lambda operation before changing calibration.
- Where supported, compare engine speed, throttle, air mass, lambda, fuel corrections and ignition or knock-related values under repeatable conditions. Confirm units, availability and sample rate for the specific diagnostic tool; a displayed air or torque value may be calculated rather than independently measured.
- If the documented variable-manifold engine has a power complaint, the Škoda Octavia workshop procedure checks changeover operation, N156, vacuum lines and linkage. A failed changeover has several possible electrical, vacuum and mechanical causes; follow the current procedure for the actual installation.
- Confirm that any calibration definition matches the exact file and that axes, units and functions have been validated. The cited factory descriptions do not provide universal map addresses, performance gains or safe timing changes. A plausible map name is not proof that it controls the intended function.
Octavia 1.6/74 kW changeover test example
The reproduced Škoda workshop manual gives a practical way to investigate a power complaint on its 1.6/74 kW Simos 2 installation. With the engine warm, it describes observing the vacuum actuator and linkage while the engine is briefly accelerated and returned to idle. The linkage is expected to move and return. If it does not, the procedure calls for checking N156 and its actuation, vacuum hoses and connections, and free movement of the changeover mechanism. This brief workshop test does not by itself establish the switching point under road load or identify the failed part. Follow the current procedure and conditions for the vehicle being tested. Škoda intake-manifold changeover test.
In the same manual’s N156 electrical test, the specified resistance across the disconnected valve is 25–35 Ω. It separately checks supply and uses final-control diagnosis to check actuation. A coil within that range does not prove the valve moves, vacuum is available or the linkage works. The stated value and test equipment belong to that workshop example, not every N156 installation; verify the current specification and circuit for the actual engine.
For the Octavia 1.6/74 kW workshop example, see Simos 2 Octavia lambda adaptation and knock log review for scoped measuring-block meanings and interpretation.
Processor and memory
An owner report on a Simos 2 unit with part number 06A906019BQ (Siemens 5WP4441-02) identifies the processor as a Siemens/Infineon SAK-C167CR-LM and the flash as an AMD AM29F200BB, read by bootstrap loader and in-circuit by K-line (single owner report; seen in search summary, as the forum was not directly accessible). A tool vendor's listing separately names Siemens 5WP4 Simos 2.x (2-plug) as a 29F200 flash unit for immobiliser work. Both are single-source, unit-specific statements, not a processor specification for every Simos 2 variant.
Reading and writing
Diagnostic access, reading the calibration, reading all relevant memory and writing a modified file are separate capabilities. The diagnostic supplier's 2.1 vehicle listing does not establish any particular flashing protocol. Check the tool provider's exact ECU and software coverage, memory scope, checksum handling, power supply and recovery procedure before writing; retain a restorable original in the appropriate format. A purchased or supplied original is not automatically the vehicle's current calibration or a complete backup.
For a programming-tool example, the ECU Tools CombiLoader listing includes Siemens SIMOS 2.x in its base software's ST10F27x/C16x bootstrap-loader coverage. The listing does not identify all supported ECU part and software numbers or specify which memory regions are accessible for each 2.x controller. This is a product-specific claim, not proof of OBD read/write support or that its output contains all ECU and immobiliser data. Confirm the exact unit, connection, read/write operation and recovery coverage with the provider and record the memory area and provenance of every read.
Bench connection pinout
Bench-connection pins for this unit are drawn in Simos 2 bench connection pinout.
Sources
- Škoda SSP 15: Octavia, AEH engine description. Simos 2 and variable intake. Accessed 17 November 2026.
- Škoda SSP 19: 1.6 and 1.8-litre petrol engines, French edition, AEH system overview and N156 description. Accessed 17 November 2026.
- Audi SSP 182: A3 engineering, AEH Simos 2 system overview. Accessed 17 November 2026.
- Volkswagen SSP 191: Passat 1997, 1.6 AHL engine data. Accessed 17 November 2026.
- Škoda Octavia Mk1 1.6/74 kW workshop manual, iFixit-hosted copy, AEH/AKL technical data; intake-manifold changeover test, separately reproduced. Accessed 17 November 2026.
- Snap-on European Software Applications Guide. Product-specific Simos 2.1 diagnostic coverage. Accessed 17 November 2026.
- Nefarious Motorsports: VAG Simos2 ECU bench read/write with Galetto/Minimon. Owner report: processor and flash on a 5WP4441-02 unit; seen in search summary, direct access returned HTTP 403. Accessed 19 November 2026.
- IMMO Decoding GUIDE, tool vendor list. Siemens 5WP4 Simos 2.x (2 plug) flash 29F200 entry; seen in search summary. Accessed 19 November 2026.
Revision 7: Simos 2
Simos 2 is a Siemens petrol engine-management family documented on naturally aspirated Volkswagen Group engines. Škoda and Audi training material identifies Simos 2 on the 1.6-litre AEH; a Škoda workshop manual also lists the 1.6 AKL with Simos 2. The precise ECU suffix and software must be identified on the actual unit before selecting a definition or programming method.
Documented examples and identification
Škoda SSP 15 describes the 1.6 AEH with Simos 2, a hot-film air-mass meter and a variable intake manifold in the Octavia. A Škoda Octavia workshop-manual copy lists AEH and AKL as 1,595 cm³, 74 kW naturally aspirated engines with Simos 2. It is a table for those applications, not a complete fitment catalogue or proof of an individual ECU suffix.
VW SSP 191 separately lists Simos 2 on the Passat 1.6 AHL and says that Passat installation has no twin-path intake manifold. Do not assume the Octavia manifold hardware is present because a car has a Simos 2 ECU. Audi SSP 182 also names Simos 2 for its A3 AEH example. These sources identify the family without allocating a suffix to every example.
A Snap-on diagnostic application guide lists selected SEAT Ibiza 1.6 AEH and AKL examples under Simos 2.1; this is the tool supplier's application coverage, not a universal fitment or flashing statement. Record the ECU label, full part and software numbers, engine code and gearbox, then match them to the selected tool's current documentation. A petrol Simos 2.1 is distinct from the later diesel PCR 2.1 label.
A separately reproduced SEAT injection-system technical-data table explicitly pairs AEH and AKL with Simos 2.1, while its APF and AUR column names Simos 3.3. It is a scoped workshop table, not proof of the controller in every vehicle with those engine codes. Its technical figures and service procedures are for the listed installations; identify the ECU before deciding which column and diagnostic procedure apply.
For Volkswagen’s separately documented AHT 1.0 system, see Simos 2P, including its manifold-pressure load sensing and paired port injection. Identify the fitted controller before applying either example.
AEH air and engine control
For its AEH example, Audi SSP 182 lists hot-film air-mass meter G70, engine-speed sender G28, Hall sender G40, lambda sensor G39, knock sensor G61, coolant and intake-air temperature sensors and throttle-control unit J338. It shows four injection valves and two ignition coils. The throttle assembly in that system includes a throttle potentiometer, a positioner potentiometer and an idle switch; verify the actual hardware before applying details to another ECU or vehicle.
On the variable-manifold AEH described by Škoda SSP 19, the ECU operates N156 in response to load and engine speed and uses vacuum to change intake runner length. The long path supports lower-speed torque and the short path the higher-speed range. The programme describes the short path as the fallback when the valve signal is absent. It also describes a separate high-speed changeover used for soft speed limiting in that example: these are factory strategy descriptions, not generic switch points or an instruction to raise a limiter.
Diagnosis and tuning baseline
- Record the exact controller and software, fuel, faults, modifications and the complaint. Investigate ignition misfires, intake leaks, air-meter and coolant-temperature plausibility, fuel delivery and lambda operation before changing calibration.
- Where supported, compare engine speed, throttle, air mass, lambda, fuel corrections and ignition or knock-related values under repeatable conditions. Confirm units, availability and sample rate for the specific diagnostic tool; a displayed air or torque value may be calculated rather than independently measured.
- If the documented variable-manifold engine has a power complaint, the Škoda Octavia workshop procedure checks changeover operation, N156, vacuum lines and linkage. A failed changeover has several possible electrical, vacuum and mechanical causes; follow the current procedure for the actual installation.
- Confirm that any calibration definition matches the exact file and that axes, units and functions have been validated. The cited factory descriptions do not provide universal map addresses, performance gains or safe timing changes. A plausible map name is not proof that it controls the intended function.
Octavia 1.6/74 kW changeover test example
The reproduced Škoda workshop manual gives a practical way to investigate a power complaint on its 1.6/74 kW Simos 2 installation. With the engine warm, it describes observing the vacuum actuator and linkage while the engine is briefly accelerated and returned to idle. The linkage is expected to move and return. If it does not, the procedure calls for checking N156 and its actuation, vacuum hoses and connections, and free movement of the changeover mechanism. This brief workshop test does not by itself establish the switching point under road load or identify the failed part. Follow the current procedure and conditions for the vehicle being tested. Škoda intake-manifold changeover test.
In the same manual’s N156 electrical test, the specified resistance across the disconnected valve is 25–35 Ω. It separately checks supply and uses final-control diagnosis to check actuation. A coil within that range does not prove the valve moves, vacuum is available or the linkage works. The stated value and test equipment belong to that workshop example, not every N156 installation; verify the current specification and circuit for the actual engine.
For the Octavia 1.6/74 kW workshop example, see Simos 2 Octavia lambda adaptation and knock log review for scoped measuring-block meanings and interpretation.
Processor and memory
An owner report on a Simos 2 unit with part number 06A906019BQ (Siemens 5WP4441-02) identifies the processor as a Siemens/Infineon SAK-C167CR-LM and the flash as an AMD AM29F200BB, read by bootstrap loader and in-circuit by K-line (single owner report; seen in search summary, as the forum was not directly accessible). A tool vendor's listing separately names Siemens 5WP4 Simos 2.x (2-plug) as a 29F200 flash unit for immobiliser work. Both are single-source, unit-specific statements, not a processor specification for every Simos 2 variant.
Reading and writing
Diagnostic access, reading the calibration, reading all relevant memory and writing a modified file are separate capabilities. The diagnostic supplier's 2.1 vehicle listing does not establish any particular flashing protocol. Check the tool provider's exact ECU and software coverage, memory scope, checksum handling, power supply and recovery procedure before writing; retain a restorable original in the appropriate format. A purchased or supplied original is not automatically the vehicle's current calibration or a complete backup.
For a programming-tool example, the ECU Tools CombiLoader listing includes Siemens SIMOS 2.x in its base software's ST10F27x/C16x bootstrap-loader coverage. The listing does not identify all supported ECU part and software numbers or specify which memory regions are accessible for each 2.x controller. This is a product-specific claim, not proof of OBD read/write support or that its output contains all ECU and immobiliser data. Confirm the exact unit, connection, read/write operation and recovery coverage with the provider and record the memory area and provenance of every read.
Bench connection pinout
Bench-connection pins for this unit are drawn in Simos 2 bench connection pinout.
Sources
- Škoda SSP 15: Octavia, AEH engine description. Simos 2 and variable intake. Accessed 17 November 2026.
- Škoda SSP 19: 1.6 and 1.8-litre petrol engines, French edition, AEH system overview and N156 description. Accessed 17 November 2026.
- Audi SSP 182: A3 engineering, AEH Simos 2 system overview. Accessed 17 November 2026.
- Volkswagen SSP 191: Passat 1997, 1.6 AHL engine data. Accessed 17 November 2026.
- Škoda Octavia Mk1 1.6/74 kW workshop manual, iFixit-hosted copy, AEH/AKL technical data; intake-manifold changeover test, separately reproduced. Accessed 17 November 2026.
- Snap-on European Software Applications Guide. Product-specific Simos 2.1 diagnostic coverage. Accessed 17 November 2026.
- Nefarious Motorsports: VAG Simos2 ECU bench read/write with Galetto/Minimon. Owner report: processor and flash on a 5WP4441-02 unit; seen in search summary, direct access returned HTTP 403. Accessed 19 November 2026.