by llandowtuninguk@gmail.com Restore the 52-position J1-J3 function table removed in revision 4 (copied unchanged from revision 3); keep the link to the structured pinout article
Removed text is struck through; added text is highlighted.
Autronic sm2 manufacturer product image: Autronic; reproduced with permission.
Autronic SM2 is a standalone or earlier programmable engine-management system. SM2 lists eight selectable peak-and-hold injector drivers and four ignition outputs; standard ignition does not have dwell control. It has separate J1/J2/J3 connector arrangements and RS232 communication. Model-specific information.
Identification and features
Record the ECU label, model, part number, hardware revision, firmware, configured injectors, ignition hardware and loom before comparing systems. Some outputs can be reassigned; hardware, software, current limits and engine-specific options determine what is actually available.
Processor
Autronic's product page (manufacturer documentation) gives the SM2 microcontroller as a 16-bit Intel part running at 16 MHz. The exact part number is not stated in the sources checked.
Engine applications
The SM2 is a universal unit rather than a vehicle-specific ECU. Per Autronic it suits port-injected spark-ignition engines without drive-by-wire throttle or feedback-controlled variable camshafts, including high-output supercharged or turbocharged engines, two-rotor rotary and two-stroke engines, and engines with uneven firing intervals such as two- and four-cylinder V motorcycle engines and V6 car engines. Selectable cylinder counts are 1 to 8, 10, 12, 14 and 16, with full sequential injection up to eight cylinders and semi-sequential operation above that. Autronic positions it for high-performance motorsport. No specific engine codes are listed by the manufacturer.
Hardware per Autronic: supply 6.2 to 23 V, eight injector drivers selectable 4 A/1 A or 2 A/0.5 A peak/hold, four 1 A open-collector ignition outputs, four on-off outputs, two high-side PWM outputs, RS232 serial, and a 52-way AMP connector made up of 10-way, 18-way and 24-way plugs.
Wiring and pinout
Consult the Autronic SM2 wiring and documentation source and identify the exact connector face, part and version. Do not apply wiring from a similarly named model. If an exact drawing is unavailable for the unit at hand, obtain it from the manufacturer or supplier before making connections.
SM2 standard loom connector assignments
Autronic's SM2 basic wiring, traction-control option, drawing SM2WR105 revision 001 identifies positions 1 to 10 as J1, 11 to 28 as J2 and 29 to 52 as J3. The complete function table for all 52 positions follows and is also on the Autronic SM2 connector pinout page with redrawn pin-index diagrams. Positions 21, 23, 42 and 43 are not labelled in the drawing, which does not declare them safe to use. J4 is the serial connection: RxD, TxD and ground are shown but physical pin numbers are not supplied. Diagram redrawn by Tuning Wiki from the Autronic drawing.
Autronic SM2 model informationWiring, manuals or technical archiveAutronic manufacturer index
Sources
Autronic SM2 product page. Manufacturer. Accessed 19 November 2026.SM2 wiring drawing SM2WR105 revision 001. Manufacturer. Accessed 19 November 2026.
Rendered revisions
Open each version to inspect formatting, tables and photographs.
Revision 5: Autronic SM2Autronic sm2 manufacturer product image: Autronic; reproduced with permission.
Autronic SM2 is a standalone or earlier programmable engine-management system. SM2 lists eight selectable peak-and-hold injector drivers and four ignition outputs; standard ignition does not have dwell control. It has separate J1/J2/J3 connector arrangements and RS232 communication. Model-specific information.
Identification and features
Record the ECU label, model, part number, hardware revision, firmware, configured injectors, ignition hardware and loom before comparing systems. Some outputs can be reassigned; hardware, software, current limits and engine-specific options determine what is actually available.
Processor
Autronic's product page (manufacturer documentation) gives the SM2 microcontroller as a 16-bit Intel part running at 16 MHz. The exact part number is not stated in the sources checked.
Engine applications
The SM2 is a universal unit rather than a vehicle-specific ECU. Per Autronic it suits port-injected spark-ignition engines without drive-by-wire throttle or feedback-controlled variable camshafts, including high-output supercharged or turbocharged engines, two-rotor rotary and two-stroke engines, and engines with uneven firing intervals such as two- and four-cylinder V motorcycle engines and V6 car engines. Selectable cylinder counts are 1 to 8, 10, 12, 14 and 16, with full sequential injection up to eight cylinders and semi-sequential operation above that. Autronic positions it for high-performance motorsport. No specific engine codes are listed by the manufacturer.
Hardware per Autronic: supply 6.2 to 23 V, eight injector drivers selectable 4 A/1 A or 2 A/0.5 A peak/hold, four 1 A open-collector ignition outputs, four on-off outputs, two high-side PWM outputs, RS232 serial, and a 52-way AMP connector made up of 10-way, 18-way and 24-way plugs.
Wiring and pinout
Consult the Autronic SM2 wiring and documentation source and identify the exact connector face, part and version. Do not apply wiring from a similarly named model. If an exact drawing is unavailable for the unit at hand, obtain it from the manufacturer or supplier before making connections.
SM2 standard loom connector assignments
Autronic's SM2 basic wiring, traction-control option, drawing SM2WR105 revision 001 identifies positions 1 to 10 as J1, 11 to 28 as J2 and 29 to 52 as J3. The complete function table for all 52 positions follows and is also on the Autronic SM2 connector pinout page with redrawn pin-index diagrams. Positions 21, 23, 42 and 43 are not labelled in the drawing, which does not declare them safe to use. J4 is the serial connection: RxD, TxD and ground are shown but physical pin numbers are not supplied. Diagram redrawn by Tuning Wiki from the Autronic drawing.
Connector / position
Function in drawing
J1 1
ECU +12 V supply
J1 2
Injector 8 output
J1 3
ECU +12 V supply
J1 4
Injector 7 output
J1 5
Injector 6 output
J1 6
Injector 5 output
J1 7
Injector 4 output
J1 8
Injector 3 output
J1 9
ECU ground
J1 10
ECU ground
J2 11
Injector 2 output
J2 12
PWM 1 output (idle control)
J2 13
Injector 1 output
J2 14
PWM 2 output (boost control)
J2 15
Ignition switch input
J2 16
Solenoid 3 output (spare)
J2 17
Analogue output
J2 18
Coolant temperature input
J2 19
Coolant temperature ground
J2 20
O2 / EGT input
J2 21
Not labelled in source
J2 22
Exhaust back pressure input
J2 23
Not labelled in source
J2 24
Intake air temperature input
J2 25
Intake air ground
J2 26
Throttle position input
J2 27
Throttle position ground
J2 28
Throttle position supply
J3 29
Auxiliary 2 analogue input
J3 30
Auxiliary 4 analogue input
J3 31
Auxiliary 1 analogue input
J3 32
Auxiliary 3 analogue input
J3 33
Auxiliary analogue input ground
J3 34
Trigger supply
J3 35
Trigger ground
J3 36
Reference trigger input
J3 37
Cylinder pulse trigger input
J3 38
Spare speed input (turbo tachometer)
J3 39
Vehicle speed input
J3 40
Switch 1 input (A/C request / traction control enable)
Revision 5: Autronic SM2Autronic sm2 manufacturer product image: Autronic; reproduced with permission.
Autronic SM2 is a standalone or earlier programmable engine-management system. SM2 lists eight selectable peak-and-hold injector drivers and four ignition outputs; standard ignition does not have dwell control. It has separate J1/J2/J3 connector arrangements and RS232 communication. Model-specific information.
Identification and features
Record the ECU label, model, part number, hardware revision, firmware, configured injectors, ignition hardware and loom before comparing systems. Some outputs can be reassigned; hardware, software, current limits and engine-specific options determine what is actually available.
Processor
Autronic's product page (manufacturer documentation) gives the SM2 microcontroller as a 16-bit Intel part running at 16 MHz. The exact part number is not stated in the sources checked.
Engine applications
The SM2 is a universal unit rather than a vehicle-specific ECU. Per Autronic it suits port-injected spark-ignition engines without drive-by-wire throttle or feedback-controlled variable camshafts, including high-output supercharged or turbocharged engines, two-rotor rotary and two-stroke engines, and engines with uneven firing intervals such as two- and four-cylinder V motorcycle engines and V6 car engines. Selectable cylinder counts are 1 to 8, 10, 12, 14 and 16, with full sequential injection up to eight cylinders and semi-sequential operation above that. Autronic positions it for high-performance motorsport. No specific engine codes are listed by the manufacturer.
Hardware per Autronic: supply 6.2 to 23 V, eight injector drivers selectable 4 A/1 A or 2 A/0.5 A peak/hold, four 1 A open-collector ignition outputs, four on-off outputs, two high-side PWM outputs, RS232 serial, and a 52-way AMP connector made up of 10-way, 18-way and 24-way plugs.
Wiring and pinout
Consult the Autronic SM2 wiring and documentation source and identify the exact connector face, part and version. Do not apply wiring from a similarly named model. If an exact drawing is unavailable for the unit at hand, obtain it from the manufacturer or supplier before making connections.
SM2 standard loom connector assignments
Autronic's SM2 basic wiring, traction-control option, drawing SM2WR105 revision 001 identifies positions 1 to 10 as J1, 11 to 28 as J2 and 29 to 52 as J3. The complete function table for all 52 positions follows and is also on the Autronic SM2 connector pinout page with redrawn pin-index diagrams. Positions 21, 23, 42 and 43 are not labelled in the drawing, which does not declare them safe to use. J4 is the serial connection: RxD, TxD and ground are shown but physical pin numbers are not supplied. Diagram redrawn by Tuning Wiki from the Autronic drawing.
Connector / position
Function in drawing
J1 1
ECU +12 V supply
J1 2
Injector 8 output
J1 3
ECU +12 V supply
J1 4
Injector 7 output
J1 5
Injector 6 output
J1 6
Injector 5 output
J1 7
Injector 4 output
J1 8
Injector 3 output
J1 9
ECU ground
J1 10
ECU ground
J2 11
Injector 2 output
J2 12
PWM 1 output (idle control)
J2 13
Injector 1 output
J2 14
PWM 2 output (boost control)
J2 15
Ignition switch input
J2 16
Solenoid 3 output (spare)
J2 17
Analogue output
J2 18
Coolant temperature input
J2 19
Coolant temperature ground
J2 20
O2 / EGT input
J2 21
Not labelled in source
J2 22
Exhaust back pressure input
J2 23
Not labelled in source
J2 24
Intake air temperature input
J2 25
Intake air ground
J2 26
Throttle position input
J2 27
Throttle position ground
J2 28
Throttle position supply
J3 29
Auxiliary 2 analogue input
J3 30
Auxiliary 4 analogue input
J3 31
Auxiliary 1 analogue input
J3 32
Auxiliary 3 analogue input
J3 33
Auxiliary analogue input ground
J3 34
Trigger supply
J3 35
Trigger ground
J3 36
Reference trigger input
J3 37
Cylinder pulse trigger input
J3 38
Spare speed input (turbo tachometer)
J3 39
Vehicle speed input
J3 40