Tuning Wiki

Tuning a diesel is a change to the quantity that is injected and to the moment it is injected. The hardware decides what that change actually is. On a mechanical in-line pump it is a rack and a governor. On an electronic in-line pump it is a rack position the ECU commands. On a solenoid distributor pump or a unit injector it is how long a valve stays closed. On common rail it is rail pressure as well as injector opening time. Moving a map that has the same name on two of these files does not move the same part.

The pumps themselves are diesel injection pumps. Quantity limits that sit under the driver's request are EDC15 fuel control, EDC16 torque and fuel and diesel smoke limits. Timing, pilot and combustion noise are diesel injection timing. This page does not give rack stops, timing offsets, opening pressures or map values. Those belong to the pump and the software in front of you. A road vehicle still has to meet the law where it is used.

Air, fuel and hardware limits

Diesel control is not free of air, pressure or temperature constraints. Increasing fuel without sufficient usable air can increase soot, and a higher torque request can encounter fuel, air, thermal or mechanical limits. Bosch describes an injected-quantity limitation using air quantity and operating conditions to limit soot and overload; the exact implementation is controller-specific. Diesel smoke limits.

Common rail is one electronic diesel architecture, alongside electronically controlled distributor, in-line and unit-injector systems. A pressure, timing or duration value from one cannot be assumed to apply to another. Establish the system and software, check baseline health, and compare requested with actual rail pressure, air and boost under controlled conditions. High-pressure diesel fuel can penetrate skin; follow the manufacturer's depressurisation and test procedures.

Validate the complete turbo system under load

A short peak-power run does not establish how the engine, cooling and aftertreatment behave during a sustained demand. Record the baseline and compare repeatable conditions, including engine speed and load, ambient conditions, coolant and oil temperatures, requested and actual boost, fuel request and available air. Where suitable equipment is fitted, record turbine-inlet pressure, exhaust temperature at its identified location and turbo speed. Garrett lists these as useful turbo-system monitoring channels in its system checklist.

Intake manifold pressure and exhaust pressure before the turbine are different measurements. An increase in boost does not by itself prove that the compressor, turbine or engine has sufficient margin. Garrett notes that operation towards compressor choke can increase compressor speed, discharge temperature and exhaust backpressure; the outcome depends on the actual match. Garrett: choosing a turbocharger. Record pressure reference, sensor location and units when comparing traces.

Use a suitable controlled test facility and the engine and equipment manufacturers’ operating limits. Watch temperatures and pressures throughout the intended duration, retain the applicable protection and aftertreatment functions, and stop to investigate an unsafe trend. Exhaust probe position and response affect the reading; EGT in engine tuning explains why one generic number cannot be transferred between installations. Smoke and air limitation are covered in diesel smoke limits.

Mechanical in-line and mechanical distributor pumps

There is no calibration file. The quantity is the effective stroke of the plunger, set by rotating it with the control rack on a PE pump, or by the control collar on a port-and-helix VE. A flyweight governor moves that rack or collar. Bosch describes the mechanical governor as restricted to simple open-loop control, and as unable to register many of the variables an ECU later used. When an electronic rack controller is given a similar characteristic, Bosch points at the mechanical RQ and RQV governors rather than treating every governor as one shape.

Timing is a different adjustment, and on a standard PE it is not a sleeve you can map. Start of delivery is the plunger covering the inlet port. Changing it means the pump's installation timing, or a speed-dependent timing device where one is fitted. The control-sleeve pump is the in-line pump that can move start of delivery on its own. On a VE, the timing device rotates the roller ring, and that rotation is the start of delivery. Advancing the pump as a lump, and advancing only the roller ring, are different jobs. The nozzle does not know which one you did. It opens when the pressure in the line reaches its opening pressure.

The nozzle is part of the calibration. Opening pressure is the spring tension, set with a shim. A two-spring holder gives a short first lift and then the main lift, which Bosch describes as a softer idle and part-load burn. Hole count, hole diameter and a throttling pintle change the spray. None of that appears in an ECU read, because there is no ECU read. Fitting a different nozzle to a pump that was set on a test bench with calibrating nozzles at a stated opening pressure changes the quantity and the timing the engine sees, even though the rack was not touched.

Bosch's pump test bench is the instrument for this calibration. The pump is driven at controlled speed on calibrating oil, and delivery is measured through nozzles whose opening pressures are set for the test. That is a check of the pump's delivery, cylinder to cylinder, against the specification. It is not a road log, and it does not include the engine's air, smoke or governor response under boost.

Electronic in-line pumps

PE-EDC keeps the helix. The ECU's output is control-rack travel. Bosch programs a pump map that, from engine speed, gives the rack travel for the desired quantity. A rack-travel sensor closes the loop. More solenoid current is more fuel. With the solenoid off, a spring returns the rack to no delivery. A tune that raises the desired quantity does nothing until this map, or the loop around it, actually moves the rack further out. The solenoid cannot command travel past the maximum delivery position.

Start of injection is a free command only on the control-sleeve version. There the second solenoid's current is the timing: low current retards start of delivery, high current advances it. A PE-EDC file for a pump without the sleeve does not contain a sleeve command that the hardware will follow. Confirm the pump on the engine before treating a start-of-injection map as a sleeve map.

The nozzles are still pop nozzles. Where a needle-motion sensor is fitted, the ECU can close a timing loop on the needle lifting, and only while fuel is being injected and speed is stable. Starting and overrun are outside that loop in Bosch's description. A change to the start map is judged from that sensor when it is valid, and from smoke, noise and temperature when it is not. The sensor does not measure quantity. Quantity is the rack.

Smoke, boost and temperature limits, if this ECU has them, still sit under the quantity the rack is told to deliver. Raising the rack map and leaving the air limit where it is leaves the rack on the limit. The limit that wins is the same selection on a rack as it is on a common-rail duration.

VE-EDC and the solenoid distributor pumps

VE-EDC meters with the control collar, not with a rail. The moving-magnet actuator sets the collar, the Hall sensor reports it, and the timing-device solenoid sets the roller ring. The calibration is a quantity, expressed as collar position against speed, and a timing-device command. Return springs shut delivery off when the actuator is de-energised, and an electrical shut-off valve is a second path. There is one delivery event per cylinder per revolution of the pumping mechanism. A common-rail pilot map does not belong to this pump.

VP30 and VP44 meter with the high-pressure solenoid. Closed, the chamber can build pressure. Open, the fuel spills and that injection does not happen. The delivery period is the quantity. The timing device is positioned in a closed loop from a crankshaft signal and an angle sensor inside the pump, and Bosch describes that loop as working during overrun, so the device can already be in place for the next injection. The relationship between start of delivery at the pump and start of injection at the nozzle is stored as a wave-propagation map, because the line is still between them. A needle sensor can be added on top. It is optional in that description, not standard on every VP44.

On the Saab 9-3 D223L the number the engine ECU calculates is a permitted fuel mass per combustion, and it sends that mass and a timing request to the pump. Tuning the engine file and tuning the pump controller are then two writes, and only the installation tells you which box holds which map. VP44 and PSG16 is the case where both jobs sit on the pump. Identify the controller before opening a file that a tool has labelled VP44.

Bosch lists pilot injection as an optional function on the EDC15M overview, which is this solenoid-distributor family. It is not the five-pulse pattern of a later common rail, and it is not present just because the pump is a VP44. The EDC15 page is the place those examples are tied to the hardware.

Unit injectors and unit pumps

The cam makes the pressure. The solenoid decides when pressure is allowed to build. BIP, the start of delivery, is the solenoid closing. The nozzle opens later, at its opening pressure. The delivery period between closure and the end of the trigger is the quantity. A longer period at the same cam speed is more fuel, until the cam lobe has passed and there is no more stroke to use. There is no rail-pressure setpoint to raise. A map of rail pressure, copied from a common-rail file or left in a definition by mistake, is not a pressure this hardware will make.

The ECU learns the solenoid's closing instant from the current waveform and corrects the next event. If BIP is missing it falls back to open-loop. A tune that moves the start of the trigger without leaving a window the BIP detection can use will lose that correction and run on the fallback. That is a property of this solenoid, described by Bosch, not a reason to disable the check.

Opening pressure is still a spring and a shim in the nozzle holder. Changing the nozzle, or its shim, changes the delay between BIP and the start of injection, and the quantity that escapes before the needle seats. The ECU's delivery period does not know the shim was changed unless the result is logged.

Pressure rises with the cam. It is high when the plunger is moving fast, and the system Bosch described reached up to 2,050 bar on the UIS because there is no long high-pressure line. That figure is a capability of the 2001 description, not a target to set. At low engine speed the same plunger is moving more slowly, so the pressure available for a given delivery period is not the full-load pressure. Extending the period into a part of the cam that is no longer rising does not keep adding fuel at that pressure.

EDC16 on a unit-injector engine still has a torque or quantity request, a smoke limit and a start-of-injection calculation. Those maps are real. They are executed as a solenoid window, not as a rack and not as a rail pressure. The V10 unit-injector account in EDC16 torque and fuel is that engine, not a common-rail CP3.

Common rail

Common rail separates the three things the older pumps tied together. The supply pump holds rail pressure. The ECU chooses the pressure, the moment the injector opens, and how long it stays open. Injected quantity is the time integral of fuel flow. It depends on the pressure difference across the nozzle, injector and fuel characteristics, needle motion and the command. A pressure or duration change can change delivery, but quantity is not pressure multiplied by time. Common-rail pressure-differential and injector modelling example. Pilot, main and post can exist because the rail is already at pressure. Common-rail diesel fuel systems is the hardware. Diesel injection timing is what the extra events do to noise and torque.

A tune therefore has to say which of the three moved. An increased quantity request may produce more fuel at the existing rail-pressure target if the active limits, injector duration and hardware allow it. If a limit remains active, the request alone may not change delivered quantity. Raising rail pressure without the opening time, the nozzle and the pump's delivery in mind changes the quantity a given pulse produces, and it changes the noise. The pump can only hold the pressure the rail is losing through the injectors. A target the pump cannot hold shows up as desired pressure above actual pressure. That comparison is the common-rail equivalent of the rack-travel sensor.

Injector calibration codes, C2i codes and QR codes are a correction for that injector, written so the pulse produces the intended quantity. They are not a performance map. Common-rail diesel injectors. A common-rail injector is not tested or adjusted as a conventional mechanical pop nozzle. Its internal springs and any calibration shims are specific to the design; use the correct injector test and repair plan.

EDC16 and EDC17 common-rail files are torque-structured on the applications this wiki describes: a request becomes a permitted quantity, and the quantity becomes pressure, timing and duration. The family pages are EDC16, EDC17 and MD1. A suffix is a clue. The pump on the engine is the identification.

What to log, on each system

  • Mechanical pump. There is no requested-quantity channel. Delivery is a bench measurement, and on the engine the evidence is smoke, exhaust temperature, a timing reading if a needle sensor or a clamp is fitted, and the governor's behaviour as speed rises. A boost gauge does not tell you the rack position.
  • Electronic in-line. Desired quantity, rack-travel setpoint and actual rack travel, and start of delivery or needle-motion timing where the sleeve and the sensor exist.
  • VE-EDC. Collar position against the quantity request, and the timing-device command against the needle, when a needle sensor is fitted.
  • VP30 and VP44. The quantity and timing the engine ECU requested, the delivery the pump carried out, and the timing-device position. On a two-ECU car, a log from only one of them is half the path.
  • Unit injector and unit pump. Desired quantity, the solenoid's delivery period, start of injection or BIP, and whether BIP is present or the ECU has fallen back to open loop. Rail pressure will not be a meaningful channel.
  • Common rail. Desired and actual rail pressure, the quantity after the limits, the opening time, and pilot against main. Logging a drivability complaint.

On every electronic system the original file, the hardware identity and a comparison of what the edit changed come before the log. That discipline is how an ECU is remapped. It does not apply to a mechanical governor, because the governor was never a file. It does apply the moment an actuator and an ECU are what move the rack.

Sources