Tuning Wiki

SuperFlow supplies dynamometers and test-cell controls. Its WinDyn family combines operator software, acquisition electronics, sensors and appropriately configured load-control hardware for engine and chassis applications. A conversion can replace ageing electronics on supported SuperFlow machines or be engineered for certain other makes. The exact package, brake driver and installation must be specified. See SuperFlow dynamometers and dynamometer control systems.

SuperFlow promotional graphic with WinDyn5 test and analysis screens.
WinDyn5 operating and analysis screens. Image: SuperFlow, used with permission. A working installation also needs compatible acquisition and load-control hardware.

Models and software generations

WinDyn is SuperFlow's long-running Windows-based test and acquisition family; SuperFlow dates Windows-compatible WinDyn to 1994 in its company history. An existing machine's controller electronics and software generation must be identified individually.

WinDyn5 is the manufacturer's data-acquisition and control system for supported water-brake, eddy-current and other applications. The product documentation describes configurable channels, test templates, calibration, limits, relay control and PID loops. Included and optional features depend on the machine and package; a PC application cannot drive an absorber without the appropriate control and power hardware.

Illustrative speed-hold feedback loop with a controller, load actuator, absorber and speed sensor.
Illustrative speed-hold feedback loop; hardware and control strategies vary by installation. Original diagram for Tuning Wiki, CC BY 4.0.

Test modes, acquisition and interfaces

The maker lists acceleration, step, steady-state and break-in profiles, a test-profile editor, configurable screens, graphs and analysis. Depending on equipment, a test can coordinate load and throttle with test-cell auxiliaries. WinDyn5 templates can store channel definitions, sensor calibrations, limits and control settings. The conversion product describes Ethernet-connected acquisition, atmospheric measurements, CAN integration and optional sensor or emissions equipment. Its channel figure is a system/software capability, not a claim that every base box has that many physical connectors. WinDyn5; conversion details.

For a load-controlled installation, the controller compares measured speed or load with its target and commands a matching actuator. Water-brake installations can use inlet, outlet or dual-valve arrangements; eddy-current machines require a suitable current-control power stage. The brake, actuator, sensors and cooling must be matched and verified for the specific installation. Eddy-current conversions; water-brake conversion options.

Documented dynos and conversions

ApplicationManufacturer-listed examplesCompatibility note
SuperFlow engine dynosSF-901, SF-902, SF-3000BWNamed in the WinDyn5 conversion listing; check existing control hardware and brake.
SuperFlow chassis dynosSF-849, SF-832, SF-880E and SF-250ASpecific configurations and axle arrangements vary.
Other engine-dyno makersStuska, Froude, DTS, Land & Sea, Go Power and othersManufacturer names are a starting point for an engineered conversion, not approval of every model.
Other chassis-dyno makersClayton, MAHA, Mustang, Dynojet, Dynocom, Dyno Dynamics and othersConfirm the exact brake, number of speed and load channels, original sensors and supplied power stages.

All examples above are attributed to the SuperFlow conversion listing. The supplier describes conversions for water-brake valve arrangements and air- and water-cooled eddy-current brakes; it does not mean a single off-the-shelf kit is electrically compatible with every listed machine. Regenerative or motoring AC operation requires the correct machine and drive, not just a software upgrade.

Choosing and commissioning a system

Record frame and brake model, valve or field-supply specifications, speed pickups, load-cell and temperature sensors, existing configuration and emergency circuits. Agree which wiring, sensors, control console and actuators can be retained, required test modes and data migration. Check the quote for licences, installation, calibration, training and support. Commission and verify the configured system using supplier procedures; the conversion does not increase mechanical or cooling ratings. Related: factory and aftermarket controller comparison.