Tuning Wiki
Browse MoTeC

MoTeC C185 (MoTeC part #18068) is a motorsport display and acquisition device. The information here is specific to the cited part; check the label, hardware revision, options and vehicle protocol before connection.

MoTeC C185 product photograph
MoTeC C185. Image: MoTeC, reproduced with permission. Manufacturer product page and specifications.

Specifications and options

  • 5-inch colour TFT display, 800 × 480 pixels, configurable layouts and programmable channels.
  • 250 MB internal logging; USB logging upgrade increases internal storage to 500 MB. Maximum logging rate is 1,000 samples per second.
  • Four configurable CAN buses, RS232, ten analogue voltage and four analogue temperature inputs as standard; the 44 I/O upgrade increases those input counts. Features and expansion hardware require configuration.
  • MoTeC lists 6–32 V DC operation, i2 analysis and optional T2 telemetry. External GPS and vehicle data require compatible equipment.

MoTeC identifies a previous part #18063; dimensions or construction may differ. Use the document for the unit in hand.

Connector and pinout

79-way (mating connector #68086): the table below follows the manufacturer’s pinout for part #18068. Check cavity numbering and the manufacturer's connector view; the functional map is not a physical connector-face drawing. Blank cells retain the source's unspecified function; do not assign them by assumption. Inputs marked as optional need the appropriate enabled upgrade.

PinNameFunction
1AV15Analogue Voltage Input 15 (with I/O upgrade)
2AV16Analogue Voltage Input 16 (with I/O upgrade)
3AV17Analogue Voltage Input 17 (with I/O upgrade)
4AV18Analogue Voltage Input 18 (with I/O upgrade)
5AV19Analogue Voltage Input 19 (with I/O upgrade)
60VSensor 0 V
7BAT–Battery Negative
8BAT+Battery Positive
9AUX1Auxiliary Output 1
10AUX2Auxiliary Output 2
11AUX3Auxiliary Output 3
12AUX4Auxiliary Output 4
13AUX5Auxiliary Output 5
14AUX6Auxiliary Output 6
15RS232-2 TXRS232-2 Transmit Output
16RS232-2 RXRS232-2 Receive Input
170VSensor 0 V
185VSensor 5 V
19AV7Analogue Voltage Input 7
20AV8Analogue Voltage Input 8
21AV9Analogue Voltage Input 9
22AV10Analogue Voltage Input 10
23AV11Analogue Voltage Input 11 (with I/O upgrade)
24AV12Analogue Voltage Input 12 (with I/O upgrade)
25AV13Analogue Voltage Input 13 (with I/O upgrade)
26AV14Analogue Voltage Input 14 (with I/O upgrade)
270VSensor 0 V
285VSensor 5 V
29VID1Video Input 1
30VID0VVideo 0 V
31VID2Video Input 2
32VID3Video Input 3
330VSensor 0 V
34AT1Analogue Temp Input 1
35AT2Analogue Temp Input 2
36AT3Analogue Temp Input 3
37AT4Analogue Temp Input 4
38AT5Analogue Temp Input 5 (with I/O upgrade)
39AT6Analogue Temp Input 6 (with I/O upgrade)
400VSensor 0 V
41AT7Analogue Temp Input 7 (with I/O upgrade)
42AT8Analogue Temp Input 8 (with I/O upgrade)
430VSensor 0 V
445VSensor 5 V
45AV1Analogue Voltage Input 1
46AV2Analogue Voltage Input 2
47AV3Analogue Voltage Input 3
48AV4Analogue Voltage Input 4
49AV5Analogue Voltage Input 5
50AV6Analogue Voltage Input 6
510VSensor 0 V
52DIG1Digital Input 1
53DIG2Digital Input 2
54DIG3Digital Input 3
55DIG4Digital Input 4
560VSensor 0 V
57SW1Switch Input 1
58SW2Switch Input 2
59CAN4LCAN 4 Low
60CAN4HCAN 4 High
610VSensor 0 V
628VSensor 8 V
63SPD1Speed Input 1
64SPD2Speed Input 2
65SPD3Speed Input 3
66SPD4Speed Input 4
67E-TX+Ethernet Transmit +
68E-TX-Ethernet Transmit –
69AV20Analogue Voltage Input 20 (with I/O upgrade)
70RS232-1 TXRS232 Transmit Output
71CAN3LCAN 3 Lo
72CAN3HCAN 3 Hi
73CAN1LCAN 1 Lo
74CAN1HCAN 1 Hi
75CAN2LCAN 2 Lo/RS232 Ground Input
76CAN2HCAN 2 Hi/RS232 Receive Input
77E-RX+Ethernet Receive +
78E-RX–Ethernet Receive –
79RS232-1 RXRS232 Receive Input

Wiring and configuration

MoTeC C185 simplified power and CAN wiring
Power and CAN example, functional schematic rather than connector geometry. Original Tuning Wiki illustration based on the MoTeC product pinout; verify the actual harness and matching ECU.

Use the correct connector, power and sensor return for this unit. Match CAN high and low to a compatible, correctly configured network and check existing termination. ECU channels, sensors and lap timing depend on the specific hardware, protocol, configuration and licensed options. Use manufacturer instructions for wire gauge, supply protection and continuity checks; do not connect vehicle battery voltage to a sensor reference output.

MoTeC i2 supports reviewing recorded data; Pro analysis and T2 telemetry require the applicable upgrades. A telemetry licence alone does not provide a radio or cellular connection. See the MoTeC manufacturer guide for family comparisons and references.

Data analysis software

MoTeC i2 data analysis with channel traces and gauges
MoTeC i2 data analysis showing channel traces and gauges. Image: MoTeC, reproduced with permission; manufacturer image.

The C185 records data for later analysis; the exact memory, logging and Pro Analysis options depend on the unit and licence. MoTeC i2 reviews recorded channels in graphs and reports; i2 Pro features depend on the device upgrade or applicable software licence. See the manufacturer model and analysis comparison and i2 software and licence information.

Retrieve a recording with the compatible MoTeC device manager, then open it in i2 to compare channels and laps when suitable position data has been recorded. Download MoTeC software from the official downloads library; see the MoTeC manufacturer guide for the Standard and Pro options.