Tuning Wiki
Applies to

Check the hardware and software limits stated in this article.

FuelTech TurboPRO-1F+ is a programmable supplementary fuel controller for forced-induction engines. The manufacturer’s Portuguese installation and operation manual describes its eight-wire harness, boost output and original MAP/MAF clamper. Treat it as a supplementary controller and verify the exact part designation before wiring; the earlier TurboPRO-1F is separately documented and its connector cannot be assumed identical.

FuelTech TurboPRO-1F+ controller
TurboPRO-1F+ product photograph from the FuelTech installation manual cover, reproduced with permission.

Eight-way harness connector

Translated from the Portuguese manufacturer manual sections 4.1–4.2, pages 6–7. The drawing identifies the rear, wire-side view of the harness connector. Functions are specific to TurboPRO-1F+; preserve source restrictions and verify the arrangement on the actual controller. The manual gives conflicting descriptions of pin 7 grounding between text and diagram, as noted below.

PinWire colourManufacturer functionNotes
1GreyAir temperature sensor inputThe other sensor terminal goes to battery negative.
2Black shielded cableEngine speed inputInput pickup depends on the ignition arrangement; refer to the manual. The shield is internally grounded.
3WhiteOriginal MAP/MAF signal clamperIdentify the original sensor signal using the manufacturer’s procedure.
4RedIgnition-switched positive supplyThe manual recommends a 5 A fuse.
5Lilac / violetBoost control outputThe manual identifies connection to a three-way N75 valve.
6BrownSupplementary injector outputPulsed injector control; supply and injector impedance arrangements follow the manual.
7Black/whitePower groundPage 6 says chassis ground; page 7 diagram labels engine block ground. Confirm the intended ground with FuelTech for the hardware and installation.
8BlackBattery negative / signal groundManual specifies direct connection to battery negative without splices.

Separate MAP output

In addition to the eight-way harness, the manufacturer identifies a pink analog MAP signal wire emerging alongside the MAP sensor connection, for use with a data logger. This is not assigned an eight-way connector cavity in the manual.

Documentation

FuelTech TurboPRO-1F+ installation and operation manual, Portuguese. See also the separate TurboPRO-1F historic page.