FuelTech TurboPRO-1F+ is a programmable supplementary fuel controller for forced-induction engines. The manufacturer’s Portuguese installation and operation manual describes its eight-wire harness, boost output and original MAP/MAF clamper. Treat it as a supplementary controller and verify the exact part designation before wiring; the earlier TurboPRO-1F is separately documented and its connector cannot be assumed identical.

Eight-way harness connector
Translated from the Portuguese manufacturer manual sections 4.1–4.2, pages 6–7. The drawing identifies the rear, wire-side view of the harness connector. Functions are specific to TurboPRO-1F+; preserve source restrictions and verify the arrangement on the actual controller. The manual gives conflicting descriptions of pin 7 grounding between text and diagram, as noted below.
| Pin | Wire colour | Manufacturer function | Notes |
|---|---|---|---|
| 1 | Grey | Air temperature sensor input | The other sensor terminal goes to battery negative. |
| 2 | Black shielded cable | Engine speed input | Input pickup depends on the ignition arrangement; refer to the manual. The shield is internally grounded. |
| 3 | White | Original MAP/MAF signal clamper | Identify the original sensor signal using the manufacturer’s procedure. |
| 4 | Red | Ignition-switched positive supply | The manual recommends a 5 A fuse. |
| 5 | Lilac / violet | Boost control output | The manual identifies connection to a three-way N75 valve. |
| 6 | Brown | Supplementary injector output | Pulsed injector control; supply and injector impedance arrangements follow the manual. |
| 7 | Black/white | Power ground | Page 6 says chassis ground; page 7 diagram labels engine block ground. Confirm the intended ground with FuelTech for the hardware and installation. |
| 8 | Black | Battery negative / signal ground | Manual specifies direct connection to battery negative without splices. |
Separate MAP output
In addition to the eight-way harness, the manufacturer identifies a pink analog MAP signal wire emerging alongside the MAP sensor connection, for use with a data logger. This is not assigned an eight-way connector cavity in the manual.
Documentation
FuelTech TurboPRO-1F+ installation and operation manual, Portuguese. See also the separate TurboPRO-1F historic page.