EDL-1 is a compact ECU serial data logger for ECUMASTER EMU Classic and EMU Black. It records over 200 channels at 25 Hz to a compatible FAT32 SDHC card and has Bluetooth and a battery-backed real-time clock. It does not work with EMU PRO, which logs directly to USB. Sources: product page and EDL-1 manual.

Data analysis software

Transfer the EDL-1 recording from its SD card to a PC and open it in ECUMASTER Data Master to graph logged channels and analyse runs. ECUMASTER lists EDL-1 among the supported loggers. Download Data Master and its manual; see the EDL-1 manual for its recording and card requirements. Channels depend on the connected compatible EMU and configuration.
See the ECUMASTER analysis software overview.
Specifications
The manufacturer’s manual v2.8 lists 5–20 V operating supply, 64 × 45 × 18 mm, 50 g, −40 to +85 °C, two status LEDs and FAT32 SDHC cards up to 32 GB. Card and firmware compatibility should be checked against the current supported-card list. Bluetooth supports local live data and is not itself remote telemetry.
Connector and pinout
The manual identifies Molex 34793-0040 and shows the connector face, pin 1 left to pin 4 right. Verify actual component markings and orientation. EDL-1 manual, installation section.
| Pin | Function |
|---|---|
| 1 | Ground |
| 2 | RXD |
| 3 | TXD |
| 4 | Power supply |

Wiring
For the manufacturer’s EMU BLACK example, EDL pins 1–4 connect respectively to ECU B39 sensor ground, B11 RS232 TXD, B24 RS232 RXD and B26 +5 V. For the documented EMU Classic example, pins 1–4 connect to ECU pins 4 ground, 2 TXD, 1 RXD and 5 +5 V. ECUMASTER calls for shielded RXD/TXD and also documents an external 12 V and ground option. Check supply capacity, ECU revision and the manual before wiring; do not substitute an unverified ECU pinout.
Manufacturer overview: ECUMASTER dataloggers and displays. Confirm revision, loom, connector and options before installation.